Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF OCTOBER 07, 2023 SAM #7984
SOURCES SOUGHT

J -- Sources Sought Title V Emissions and Boiler Tuning Services

Notice Date
10/5/2023 1:55:52 PM
 
Notice Type
Sources Sought
 
NAICS
561210 — Facilities Support Services
 
Contracting Office
PBS R11 CONSTRUCTION SERVICES DIVSION CTR 2 WASHINGTON DC 20405 USA
 
ZIP Code
20405
 
Solicitation Number
SSNHOTDTITLEV20231005
 
Response Due
10/20/2023 2:00:00 PM
 
Archive Date
10/21/2023
 
Point of Contact
Ingrid J. Blair, Phone: 202-379-8333, Walter Kalista, Phone: 202-322-0904
 
E-Mail Address
ingrid.blair@gsa.gov, walter.kalista@gsa.gov
(ingrid.blair@gsa.gov, walter.kalista@gsa.gov)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
This is a Sources Sought Notice intended for informational purposes only. THIS IS NOT A REQUEST FOR PROPOSALS, QUOTATIONS, OR BIDS. Per Federal Acquisition Regulation (FAR) 15.201(e), responses to this notice are not an offer and cannot be accepted by the Government to form a binding contract. Responses do not affect a potential offeror's ability to respond to any future synopsis/solicitation. The Government will not provide reimbursement for any information that may be submitted in response to this notice. Respondents are solely responsible for all expenses associated with responding to this notice. This notice is a market survey being conducted solely to determine whether there are adequate contractors for the following proposed procurement. The NAICS code applicable to this proposed procurement is 561210 and the size standard is $41.5 million. The United States General Services Administration Heating Operation and Transmission�District (HOTD) operates the Central Heating and Refrigeration Plant (CHRP). This plant�produces chilled water and steam to comfort nearly 90 quasi-government buildings in the District of Columbia. This is a major source plant that is required to comply with the DC Department of Energy and Environment (DOEE) and the EPA Federal environmental regulations. These regulations required that HOTD complies with the DOEE-issued Title�V operating permit using a fully functioning and certified Continuous Emissions Monitoring�System (CEMS) while burning only natural gas as primary fuel and No. 2 grade low-sulfur�fuel oil as back-up fuel during an interrupt of natural gas supply by our supplier,�Washington Gas.�� The GSA-HOTD CHRP operates five (5) high pressure steam-generating boilers and a�cogeneration system � heat recovery steam generator (HRSG) unit 5C. Units 1, 2, and 6�are rated at 250 MMBtu/hr. Units 3 and 4 are rated at 500 MMBtu/hr. Unit 5C is rated at�326 MMBtu/hr. Because the plant is a major source for NOx with an history of previous�boiler modifications, the plant is required to comply with the New Source Performance�Standard, 40 CFR Part 60. Additionally, Boiler Nos. 3, 4 and 5C are required to comply�with 40 CFR Part 75, the NOx Budget Program � this is due to each boiler heat input�exceeds 250 MMBtu/Hr.�� Due to the applicable requirements of the Title V Permit, 40 CFR Parts 60 & 75, the�plant operates and maintains a continuous emissions monitoring system (CEMS) and a continuous opacity monitoring system (COMS) to continuously monitor NOx, O2 and opacity during boiler operation. The CEMS is also used to monitor the time, dates, fuel quantities and fuel type burned.� The environmental software/database, Stackvision, that runs on the CEMS makes it possible to comply with these complex environmental air regulations. It is a proprietary�software produced by the Environmental Systems Corporation Spectrum (ESC�Spectrum). ESC Spectrum maintains, updates, and consistently upgrades the�software/database with current and applicable environmental air regulations as they are finalized by the EPA. Each of the three contracts included in the consolidated contract specification, is intended to provide compliance pathways with all the applicable Title V, 40 CFR, Parts 60 and 75 environmental regulations.� The purpose of this statement of work (SOW) is to identify and retain a contractor for the purpose of providing a single point for a combined contact which includes the following three requirements:� 1. Relative Accuracy Test Audit � RATA�� This contract performs test audits and validation on the performance of HOTD�s CEMS. During the annual audit/validation processes, data from HOTD 's CEMS are compared to a simultaneously collected reference method test data to assess the accuracy of the CEMS readings. To maintain annual RATA, the difference between data from HOTD�s CEMS and those from the reference CEMS cannot exceed ten percentage (10%). If it exceeds 10%, then RATA will be performed twice per year.�� 2. Preventive Maintenance and Linearity Testing Services for the CEMS and Opacity�Monitors� This contract is performed on a quarterly basis to assess how closely the analyzers and opacity monitors read the actual values of NOx, O2, CO and opacity within the effective span/ranges. Where problems are found, the necessary repairs/replacements are made to ensure the systems are functioning in accordance with manufacturer�s specifications.� 3. Annual Boiler Tuning�� This contract performs annual tune-up by adjusting critical setpoints to�optimize boiler air-fuel mixture combustion performance with reference to the following:� ? Excess air.�� ? Combustion efficiency.� ? Reference Oxygen (O2).� � ��? Optimization of all other applicable boiler operating conditions and emissions�to be within range of the boiler manufacturer�s specifications and the existing�Title V Permit.� The Contractor shall also provide management, labor, supervision, vehicles, equipment, and materials to perform administration and technical support for inspections, preventive maintenance, and is responsible for the efficient, effective, economical, and satisfactory scheduled and unscheduled maintenance, and minor repairs/replacement of equipment and systems located within the property line of the Central Heating and Refrigeration Plant (CHRP). Response to this sources sought announcement will be used by the Government to make appropriate acquisition decisions. All interested Small Disadvantage Business and Small Business contractors are encouraged to submit responses, using the format described below: Corporate Information Identification Company name and company address Point of contact, phone, and email address The firm�s business type and size for NAICS Code 561210 (Facilities Support Services) Confirmation of registration in System for Award Management (Provide UEI) � � � � 2. Capabilities Narrative Please indicate the area(s) of Washington, DC or in the National Capital Region portion of the Washington Metropolitan Area, your firm currently performs these services. If services are not currently performed throughout Washington, DC, please indicate your firm�s capability to do the above listed work. If you do not have experience in The National Capital Region portion of the Washington Metropolitan Area, please describe your approach for assimilating into this market, including recruiting for staffing and subcontractor needs. Indicate if your firm would be interested in these opportunities as a prime contractor, or a Contractor Teaming Arrangement (CTA)? Provide information in sufficient detail regarding previous experience on Title V Emissions and Boiler Tuning Services requirements. Detailed information must include the following: Capability statement Description of the services performed. Identify the number of buildings and location of the buildings covered by the contract. Indicate which services were self-performed and which were subcontracted. Provide square footage of individual buildings and aggregate building square footage. Identify if the project was a government or commercial requirement. Include the type of space within the building(s). Identify the term of contract, including start and end date. Annual and aggregate contract value. Indicate how long you have performed this type of work - linearity, RATA and Boiler tuning. Indicate the size of boiler, type of boiler and the type of fuel it used. Indicate whether you are familiar with DC major source environmental air compliance regulations, including Title V,�and the Ozone - NOx Budget programs? Do you have a regulatory support team to answer critical regulatory questions? Do you have support back-end office/shop to provide quick, within 24 hours, equipment repairs and maintenance services on CEMS equipment, if and when needed? Please limit responses to no more than fifteen (15) pages and submit in either Microsoft Word or PDF file format. It is recommended to submit the information in the format as outlined above to minimize the effort of the respondent and structure the responses for ease of analysis by the Government. Responses must contain sufficient detail for the Government to make an informed decision regarding your capabilities. Respondents are advised that the Government is under no obligation to provide feedback to respondents with respect to any information submitted. No proprietary, classified, confidential, or sensitive information should be included in your response. After review of the information received, a solicitation may be published in the BETA SAM Contract Opportunities or via the Federal Supply Schedule (FSS) in the Governmentwide point of entry: GSA eBuy. A determination by the Government to proceed with the acquisition as a set-aside is within the sole discretion of the Contracting Officer. Responses must be submitted by email to Walter Kalista at walter.kalista@gsa.gov and Ingrid Blair at Ingrid.blair@gsa.gov on or before October 20, 2023, at 5:00 PM, EST.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/c5399b0846a84c218f1537277a71ef96/view)
 
Place of Performance
Address: Washington, DC 20024, USA
Zip Code: 20024
Country: USA
 
Record
SN06854657-F 20231007/231005230047 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.