SOURCES SOUGHT

66 -- Vaisala Inc. AWS310 Automatic Weather Station

Notice Date
8/25/2023 2:33:42 PM
 
Notice Type
Sources Sought
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
DEPT OF COMMERCE NOAA SEATTLE WA 98115 USA
 
ZIP Code
98115
 
Solicitation Number
NWWV41002300117SML
 
Response Due
9/2/2023 11:00:00 AM
 
Archive Date
09/17/2023
 
Point of Contact
Stephanie Long, Phone: 3035786768
 
E-Mail Address
stephanie.long@noaa.gov
(stephanie.long@noaa.gov)
 
Description
Solicitation Number: NWWV41002300117SML Notice Type: Sources Sought Synopsis Title: Vaisala Inc. AWS310 Automatic Weather Station Response Date: September 2, 2023 This is a SOURCES SOUGHT SYNOPSIS and is not a pre-solicitation announcement. The purpose of this Market Research and Sources Sought Notice is to gain knowledge of potential qualified U.S. Domestic businesses, which could include Small Business, HUBZone, 8(a), Service Disabled Veteran Owned, Women Owned Small Business firms and even Large Businesses. Responses to this Sources Sought Synopsis will be used by the Government in making appropriate acquisition decisions. The National Oceanic and Atmospheric Administration (NOAA) National Weather Service (NWS) Alaska Region (AR) maintains an Observation Network compressed of Surface Observation Platforms throughout Alaska in remote locations.� These OBS sites transmit data via GOES/Modem/TCPIP hourly aiding in the collaboration and forecasting process. The Alaska Region requires one (1) Vaisala AWS310 Automatic Weather Station in order to continue the replacement of obsolete systems within their OBS network. INTENDED USE/PURPOSE: Vaisala Automatic Weather Station AWS310 is a weather data collection system that automatically measures, processes, and stores meteorological data for professional use. AWS310 can be operated as a standalone unit, or it can be connected with other compatible Vaisala weather stations to form weather observation networks. AWS310 stations can be used for several applications, such as synoptic, aviation, and agricultural meteorology, hydrology, and climatology. It is a complete communication and data monitoring solution including sensors, electronics, mast, and power supply. A turn-key system like the Vaisala AWS310 is the only instrument capable of providing the full spectrum of data required by the Alaska Region. SPECIAL REQUIREMENTS/ESSENTIAL SALIENT FEATURES: Vaisala weather stations and instruments are fully compliant with World Meteorological Organization guidelines. To ensure continuous accuracy of measurements and calculations, AWS310 includes built-in data quality controls that test sensor data against minimum and maximum limits and changes between successive measurements. The weather station�s QML data logger continuously monitors the status of the sensors to ensure measurement reliability, notifying the user if the status of any sensor becomes invalid. All the sensors operate independently from each other, meaning that an individual sensor failure does not affect the performance of the other sensors. OPERATING ENVIRONMENT Operating environment� Outdoor use Use in wet location Yes Operating temperature 1)� ?40 � +60 �C (?40 � +140 �F) Extended operating temperature (project delivery) ?60 � +50 �C (?76 � +122 �F), cold start at ?40 �C (?40 �F) Storage temperature 2) ?60 � +70 �C (?76 � +158 �F) Operating humidity 0 � 100 %RH, non?condensing Pollution degree 2 Maximum operating altitude� 3000 m (approx. 9800 ft) 1) Excluding backup battery, QMD202, QST102?3, cellular modem, QMN101, RG13(H), SR50A, and PAA?36 X W. See the manufacturer documentation. 2) Excluding cellular modem, HMP155, and HMP110. See the manufacturer documentation. COMPLIANCE EU directives� Low Voltage Directive (2014/35/EU) EMC Directive (2014/30/EU)� RoHS Directive (2011/65/EU) amended by 2015/863 EMC compatibility� EN 61326?1, industrial environment Electrical safety EN 61010?1 Compliance marks� CE, RCM ENVIRONMENTAL COMPLIANCE Test� Applied standard or test procedure Specification Operation � Cold IEC 60068?2?1� ?40 �C (?40 �F) Dry heat IEC 60068?2?2 +60 �C (+140 �F) Vibration (sinusoidal)� IEC 60068?2?6 Frequency range 5 � 200 Hz 1.2 mm/s velocity, 5 � 12 Hz 0.7 g, 12 � 200 Hz Shock IEC 60068?2?27 5.0 g, pulse duration 11 ms with 100 pulses in each direction Damp heat, cyclic IEC 60068?2?30 +40 �C (+104 �F) / 85 � 95 %RH Vibration (random)� IEC 60068?2?64� 5 � 100 Hz Storage � Cold� IEC 60068?2?1� ?60 �C (?76 �F) Dry heat� IEC 60068?2?2 +70 �C (+158 �F) Damp heat, cyclic� IEC 60068?2?30 +40 �C (+104 �F) / 85 � 95 %RH Transport � Shock� IEC 60068?2?27 18 g, pulse duration 6 ms, with 100 pulses in each direction Rough handling� IEC 60068?2?31 Drop height 60 cm (23.62 in) Vibration (random)� IEC 60068?2?64 5 � 200 Hz EMC COMPLIANCE Test� Applied standard or test procedure Specification Emissions radiated� CISPR 32 / EN 55032, Class B 30 MHz � 2 GHz Emissions conducted to mains (AC) CISPR 32 / EN 55032, Class B 150 kHz � 30 MHz Emissions conducted to telecommunication lines CISPR 32 / EN 55032, Class B 150 kHz � 30 MHz Emissions, harmonic current EN 61000?3?2� 0 � 40th harmonic Immunity to RF field (80 MHz � 6 GHz) EN 61000?4?3 11 V/m (80 MHz � 1 GHz) 4 V/m (1 GHz � 6 GHz) Immunity to electrical fast transient EN 61000?4?4 2 kV AC, 1 kV I/O Immunity to surge� EN 61000?4?5 2 kV / 1 kV AC, 1 kV I/O Immunity to conducted RF EN 61000?4?6 4 V e.m.f. (150 kHz � 80 MHz) Immunity to voltage dips and short interrupts IEC 61000?4?11 0 % 1 cycle 40 % 10 cycles 70 % 25 cycles 0 % 250 cycles POWERING SPECIFICATIONS AC (mains) power� 100 � 240 V AC, �10 % 50 � 60 Hz 5.6 A maximum (120 V AC) Mains fuse (nominal) 10 A External DC� 16.8 � 26.4 V DC 10 A maximum Solar panel� 70 W 15.5 � 30 V DC 2.5 A maximum Internal backup battery 12 V / 26 Ah or 12 V / 52 Ah Backup battery fuse� 10 A Overvoltage category II ENC652 SPECIFICATIONS Approvals� UL 50 / UL 50E-listing IP rating IP66 NEMA rating� NEMA 4X Material Stainless steel AISI 316, painted white Size (enclosure only)� 600 � 500 � 207 mm (23.62 � 19.68 � 8.15 in) Weight (excluding backup battery)� 28.9 kg (63.7 lb) Maximum wind speed 75 m/s (168 mph) STANDARD SENSOR OPTIONS Wind speed and direction� WMT700, WA15 (dual sensors available) Weather transmitter� WXT531, WXT532, WXT535, WXT536 Athmospheric pressure BARO?1 (Class A accuracy), PTB330 (Class A accuracy, with 3 transducers) Air temperature, relative humidity, and dew point HMP110, HMP155 Rain/Precipitation RG13(H), OTT Pluvio2 L Global solar radiation SMP3, SMP6, SMP10, SMP21, SMP22, SP Lite2 Net radiation QMN101 UV radiation� SUV5 Visibility and present weather PWD22 Cloud height and sky condition� CL31 Ground temperature QMT110 Snow depth� SR50A Water level VEGAPULS 61, PAA?36 X W STANDARD COMMUNICATION OPTIONS Wireless communication� 4G LTE cellular modem with seamless fallback to 2G and 3G networks Five-band 3G cellular modem (with quad-band GSM GPRS support) Landline communication RS?232, RS?485, LAN Data collection software Vaisala Observation Network Manager NM10 Satellite communication Vaisala GOES DCP Transmitter QST102?3 Maintenance terminal software Vaisala AWS Client with StationView GUI STANDARD ACCESSORIES USB maintenance cable Removable 2 GB CF memory card DELIVERY SCHEDULE: Deliver by 6 months after award. The North American Industry Classification Code (NAICS) is 334519 with a size standard of 600 employees. Interested firms shall provide, in writing, a brief narrative (no more than 3 pages in length) and documentation to support your firm�s capability and experience meeting the requirements herein and include your firm�s name, address, point of contact, telephone number, UEID Number, CCR CAGE Number, business type and size (i.e., small, large, non-profit, educational, etc.). Any response that does not include this information will not be considered. The Government will review your response to determine if your firm has the experience, knowledge and capability to provide the items as specified above. This request for information does not constitute a commitment, implied or otherwise, that a procurement action will be issued. Nor does this request for information constitute a commitment, implied or otherwise, that any procurement action may be issued for the Government�s requirements. No entitlement to payment of direct or indirect costs or charges by the Government will arise because of the submission of contractor�s information. The Government shall not be liable for or suffer any consequential damages for proprietary information not properly identified. Proprietary information will be safeguarded in accordance with the applicable Government regulations. All contractors doing business with the Government are required to be registered and active with the System for Award Management (SAM) website. NOTE: THIS SYNOPSIS IS NOT CONSIDERED A REQUEST FOR PROPOSAL BUT A REQUEST FOR INFORMATION ONLY. No solicitation document is available. No contract will be awarded based on responses received to this notice.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/6a9e80bbaddd42db906283f1ef5b275e/view)
 
Place of Performance
Address: USA
Country: USA
 
Record
SN06808305-F 20230827/230825230107 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.