SOURCES SOUGHT
Q -- Candela Medical GentleMax Pro Plus
- Notice Date
- 8/24/2023 8:00:16 PM
- Notice Type
- Sources Sought
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- 241-NETWORK CONTRACT OFFICE 01 (36C241) TOGUS ME 04330 USA
- ZIP Code
- 04330
- Solicitation Number
- 36C24123Q1054
- Response Due
- 8/31/2023 7:00:00 AM
- Archive Date
- 10/15/2023
- Point of Contact
- Divianna Mathurin, Contract Specialist, Phone: 914-325-3258
- E-Mail Address
-
divianna.mathurin@va.gov
(divianna.mathurin@va.gov)
- Awardee
- null
- Description
- Performance Work Statement Manchester VA Medical Center Candela Gentlemax Manchester N.H. VA Medical Center has a requirement for Laser Hair Removal equipment. Laser Hair Removal equipment requirements below: - The GentleMAX Pro Plus (Nd:Yag 1064nm & Alexandrite 755 nm) Hair Removal Laser Candela GentleMAX Pro Plus has an enhance repetition rate, dual wavelength delivery system, multiple spot sizes Standard spot sizes: 6 mm, 8 mm, 10 mm, 12 mm, 15 mm, 18 mm Optional spot sizes Special delivery system: Large 20 mm, 22 mm, 24 mm, 26 mm Small 1.5 mm, 3 mm, 5 mm and 3 x 10 mm Laser Type: Nd: YAG laser / Alexandrite Beam delivery: Lens-coupled optical fiber with handpiece Pulse control: Finger switch, foot switch Dimensions: (H) 107 cm, (W) 46 cm, (D) 69 cm 42 x 18 x 27 Wavelength: 1064 nm / 755 nm Repetition Rate: Up to 10 Hz Max. delivered Energy: 68 joules (J) / 90 joules (J) Electrical: 200-240 VAC, 50/60 Hz, 30 A, 4600 VA single phase DCD cooling system: integrated controls, cryogen (HFC 134a) container, handpiece with distance gauge Spray duration: user adjustable: 10-100ms Delay duration: user adjustable: 10-100ms Post-spray duration: user adjustable: 10-50ms Air cooling system: Optional Air-Cooling Compatible (ACC) handpiece available Weight: 118 Kg (260lbs) Manchester VA has a Laser Hair Removal equipment requirement for The Gmax Pro Plus (Nd:Yag 1064nm & Alexandrite 755 nm) Hair Removal Laser 2 full day sessions every month or minimum of 24 sessions per year. This will include 5000 pulses or may require more as need basis. Training will be required onset and will not exceed 4 hours in length. A technician provided at no charge for the first 3 months and as needed after 3 months. Vendor will provide recent service and Preventive Maintenance records to the facility. Notify logistics and HTM when device on station.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/36b247b2931a424e8038c66e89e636a9/view)
- Place of Performance
- Address: Manchester VA Medical Center 718 Smyth Road, Manchester 03104
- Zip Code: 03104
- Zip Code: 03104
- Record
- SN06806637-F 20230826/230824230102 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |