Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF AUGUST 26, 2023 SAM #7942
SOLICITATION NOTICE

41 -- 100 Ton Temporary Chiller

Notice Date
8/24/2023 2:54:20 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
FA2521 45 CONS LGC PATRICK SFB FL 32925-3237 USA
 
ZIP Code
32925-3237
 
Solicitation Number
FA252123QB084
 
Response Due
8/31/2023 11:00:00 AM
 
Archive Date
10/31/2023
 
Point of Contact
Ivelisse Hernandez, Phone: 7876886725
 
E-Mail Address
ivelisse.hernandez@spaceforce.mil
(ivelisse.hernandez@spaceforce.mil)
 
Small Business Set-Aside
WOSB Women-Owned Small Business (WOSB) Program Set-Aside (FAR 19.15)
 
Description
The purpose of this modification is to notified that we are posting the Q & As. Please see new attachment. All other items remain unchanged. Provide and deliver 100 nominal ton temporary Trane chiller to building 896 The purpose of this combined synopsis and solicitation for one (1) 100 Ton Temporary Chiller Following are the salient characteristics among others: 100 Ton, 20-130 Ton Air Cooled� Model #CGAM100CANARIIS The request is for the contractor to provide delivery of a 100-ton portable air-cooled chiller. Government will offload chiller and start the chiller for operational testing. Product 100 nominal tons 460 VAC, 3 phase, 60 Hz High efficiency/performance Full factory refrigerant charge (HFC-454B) W/ Factory installed freeze protection Refrigerant isolation valves (discharge valve) UL listed to U.S. and Canadian safety standard ASHRAE 90.1 compliance for all versions up to 2016 AHRI certified Factory installed flow switch � set point 60 cm/s Standard cooling (40-65 degrees Fahrenheit/4.44-18 degrees Celsius) Grooved pipe connection Factory insulation 1-1/4�-high humidity/low evaporator temperature Performance based on water High ambient (up to 125 degrees Fahrenheit/up to 52 degrees Celsius) Complete Coat lanced aluminum fins with Blygold spray Across the line starter/direct on line Single point connection main line unit power-ancillary items require other power Circuit breaker-high fault rated control panel Enclosure type UL 1995 rated for outdoor applications LonTalk/Tracer Summit interface High A short circuit rating Elastomeric isolators W/ Water strainer factory installed Architectural louvered panels Chiller Warranty 10-year parts/labor/refrigerant warranty Packaged Chiller Modification Entire System UL Label Structural steel base with fork holes and lifting frame Galvanized base frame Frame and piping painted black Chiller painted white (1) Pump (2.4 gpm/ton) with TEFC motor @ chiller flow and 100 ft TDH Isolation butterfly valves Pump bypass piping with valve Gauges and thermometers Fill/drain line Vent line Mount, pipe, and wire chiller Supply/Return stickers Rigging/Weight sticker Electrical Information Single point power connection 460-3-60 NEMA 3R enclosure Quick connection terminals Shore power connection Auxiliary compressor heaters System wiring All wiring in EMT or liquid tight flexible metal conduit Controls Information Hand-Off pump switch Phase fail and light FS8W McDonell Miller flow switch McCrometer meter Testing NIST Traceable Test Equipment Hydrostatic Test to 150 psig or 50 psig over maximum system pressure (whichever is greater) for 2 hours.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/c863c829db1047e78938fa0bbc1c3aee/view)
 
Place of Performance
Address: Patrick AFB, FL 32925, USA
Zip Code: 32925
Country: USA
 
Record
SN06805952-F 20230826/230824230058 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.