SOURCES SOUGHT
61 -- Electrical cabling/components for air curtain Loch Raven VAMC Bldg. One Main Entrance
- Notice Date
- 6/7/2023 7:01:34 AM
- Notice Type
- Sources Sought
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- 245-NETWORK CONTRACT OFFICE 5 (36C245) LINTHICUM MD 21090 USA
- ZIP Code
- 21090
- Solicitation Number
- 36C24523Q0715
- Response Due
- 6/21/2023 7:00:00 AM
- Archive Date
- 07/21/2023
- Point of Contact
- William Chris Galletta, Contracting Officer, Phone: Services One
- E-Mail Address
-
william.galletta@va.gov
(william.galletta@va.gov)
- Awardee
- null
- Description
- Scope of Work: Building #1 Air Curtain Electrical Connection 512-23-2-849-0114 General: The Loch Raven VA Medical Center requests installation of electrical lines and components for heated air curtain located in building #1 located at 3900 Loch Raven Blvd. Baltimore, Md. About the site: The Loch Raven VA Community Living & Rehabilitation Center specializes in providing rehabilitation and recreation therapy for our recovering veterans. The main building also provides hospice, nursing home care and care for patients with Alzheimer s. Period of Performance: TBD Scope of Work: Contractor to supply all labor, supervision, equipment, tools, and materials necessary to perform installation of electrical wires and components for heated air curtain located at building #1 main entrance. Existing air curtain was found in a state of disrepair and heated air curtain is required to prevent temperatures from dropping when entering the building. Contractor shall remove and replace any defective electrical components currently in place with existing air curtain. Contractor to relocate x4 120 volt circuit breakers in breaker panel located in room 2A-09. These circuits are essential by code to be moved do to the size breaker required for existing job. Contractor to furnish and install x1 24- circuit, 3-phase main lug panel with feed from NQOD panel. Contractor to furnish and install 60 amp breaker for existing air curtain and label. Safety Precautions: The Contractor shall comply with all applicable Federal, State and local legal requirements regarding workers health and safety. The requirements include but are not limited to, those found in Federal and State Occupational Safety and Health Act (OSHA) statutes and regulations, such as applicable provisions of Title 29, Code of Federal Regulations (CFR) Parts 1910 and 1926. Contractor is solely responsible for determining the legal requirements that apply to activities and shall ensure safe and healthful working conditions for its employees. Contractor shall assume the responsibility to guard against causing of fires and/or explosions and to protect Government Property. The Contractor shall perform the work in a manner consistent with the area security and fire safety regulations especially about exits and exit way access. Utility shutdowns shall not compromise security, communication or fire safety for occupants. No flammable liquids shall be stored or used in the medical center. The necessary number and appropriate types of portable fire extinguishers are required per National Fire Protection Agency (NFPA) 10 and NFPA 241. The Contractor shall receive from the COR a permit for all cutting, welding, and soldering. All permits shall be prominently displayed during all activities. All necessary precautions shall be taken by the contractor to prevent accidental operation of any existing smoke detectors or sprinkler heads. HAZARDOUS MATERIAL REPORTING: A. The Contractor shall maintain hazardous material inventories and material safety data sheets (MSDS) for all hazardous materials (as defined in CFR 1910.120, 40 CFR s 355, 370, & 372) to be stored and used on this Medical Center. Hazardous materials must be inventoried when received and at the project s completion. The amounts used shall be maintained for the project duration. B. Hazardous Materials Inventories, Material Safety Data Sheets and material quantities used shall be submitted to the Contracting Officer for approval and copies furnished to the Contracting Officers Technical Representative. C. In the event of a spill, Contractor shall immediately notify the Contracting Officer s Technical Representative as well as the Contracting Officer. The Contractor shall be solely responsible for the expense of any cleanup and / or damage resulting of such spill, and the cleanup shall be in accordance with the applicable provisions of 40 CFR Part 761.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/a45e8fa622cc4aedaa6dab923ebc6a83/view)
- Place of Performance
- Address: Department of Veterans Affairs Loch Raven VAMC 3900 Loch Raven Blvd., Baltimore, MD 21218, USA
- Zip Code: 21218
- Country: USA
- Zip Code: 21218
- Record
- SN06708178-F 20230609/230607230119 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |