Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 19, 2023 SAM #7843
SOURCES SOUGHT

99 -- Mobile Generator 2 Mega Watt; 1050 Gal double wall fuel tank each gen set 80 Gal DEF tank Exterior fuel & DEF supply connections, ABS, Air Ride, Two Axle, 48- ISO container chassis

Notice Date
5/17/2023 1:09:25 PM
 
Notice Type
Sources Sought
 
NAICS
333618 — Other Engine Equipment Manufacturing
 
Contracting Office
248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
 
ZIP Code
33637
 
Solicitation Number
23-AP-4217-GEN
 
Response Due
6/4/2023 1:00:00 PM
 
Point of Contact
Darrin Alexander, Phone: (407) 646-4003
 
E-Mail Address
darrin.alexander2@va.gov
(darrin.alexander2@va.gov)
 
Description
2 Mega Watts Mobile Generator (Brand Name or Equal) ENGINE PACKAGE DESCRIPTION Clean Emissions Module (CEM) w/integrated Diesel Oxidation Catalyst(DOC), Selective Catalytic Reduction (SCR), & Ammonia Oxidation Catalyst (AMOX) AND IS EPA TIER 4F EMISSIONS CERTIFIED. CIRCUIT BREAKERS 3200A electrically operated, fixed type, 3 pole, insulated case circui Basler UMR Solid state trip unit for overload (time overcurrent) and fault (instantaneous) overcurrent protection Includes DC shunt trip coil activated on any monitored engine or electrical fault Undervoltage release COOLING SYSTEM Minimum 43 Deg C (117 Deg F) 500 M (1640 ft.) Vertically mounted radiator with vertical discharge Variable Speed Fan and belt guards Coolant drain line with internal valve Coolant sight gauge, level switch with shutdown Extended Life Coolant (50/50) Jacket water heater with isolation valves DISTRIBUTION PANEL Busbar connections Externally-accessible, Vibration Isolated, 3200A Frame, 100 Ka, IC, 3-pole electrically operated breaker with lock out tag out provision. Dedicated power cubicle in container wall. Dedicated cable tie down points to secure load cables and relieve cable stress. Hinged load cover door which must be closed for main breaker operation Neutral earth link Shunt Trip Remote start terminals Lockable door Side hinged Lockable doors with rust resistant pinned hinges. Bus bar connection with easy access for connections through bottom of unit, even when on the ground. Separate control and load sections. Shore Power Circuits for 240V 30A Generator heater, Fuel Transferer pump & Remote DEF tank heater 240V 50A Air Compressor Heater, Jacket Water Heater, DEF Tank Heater 120V Battery Charger Paralleling interface connections Remote start terminals Current transformers, hard mounted. ENCLOSURES 48' ISO High Cube container Sound attenuated to 82.7 dB(A) at 7 meters at 75% Prime Spill containment - (110% onboard engine fluids) Five Cat Key lockable (or padlockable) personnel doors with hold open rods Package mounted bus bar connections Vertical air discharge Removable six step stairway with handrail Stairways (3) and handrails (3) packaged in radiator compartment (8) - 24VDC Interior Lights with 60 minute wall mounted timer (1) - 120VAC wall mounted duplex GFI receptacle(connected to shore power and generator power) Sound attenuated intake EXHAUST SYSTEM Integral with flexible connector FUEL SYSTEM 1050 Gallon double wall fuel tank for each generator set 80 Gallon DEF tank Exterior fuel & DEF supply connections Dual Racor Filters with water separator and vacuum gauge Fuel Filter Spill Containment with drain Radiator mounted fuel cooler Motorized fuel priming pump Digital fuel level gauge UL142 & UN31A Approved GENERATORS AND GENERATOR ATTACHMENTS 3 Phase brushless, 6 lead, Permanent Magnet Excited Class H insulation, Class F temperature rise at 40DEC ambient (105C prime) Anti-condensation space heaters Includes Integrated voltage regulator (IVR) with KVAR/PF modes, RFI suppression, min/max exciter limiter and exciter diode monitor. VOLTAGE REGULATION Integrated voltage regulator, microprocessor based. Manual raise/lower voltage adjust capability RFI suppression, exciter limiter and exciter diode monitoring STARTING/CHARGING SYSTEM 60 amp charging alternator 24 Volt Electric Starting Motors Two Batteries (24V-Maintenance Free, 1400 CCA) Battery rack w/cables mounted in diamond plate cover Battery disconnect switch 50 Amp battery charger (wall mounted) Solar power battery maintainer with isolator CONTROL SYSTEM Generator mounted EMCP 4.4 provides power metering, protective relaying and engine and generator control, monitoring and paralleling NEMA 12, IP44 Dust Proof Enclosure UL508A Listed Integration with the IVR provides enhanced system monitoring. Ability to view and reset diagnostics of all controls networked on primary CAN datalink eliminates need for separate service tools for troubleshooting. True RMS AC metering, 3 phase Emergency Stop Button Panel illuminating lights Display navigation keys including 2 shortcut keys for engine and generator parameters Fuel level monitoring and control Rated/Idle Speed Switch Multiple stored setpoint group selection via switched input Controls: Run/Auto/Stop Engine cool-down timer Engine cycle crank Voltage & Speed Adjustments Panel illuminating lights Alarm acknowledge Alarm reset Digital indication for: RPM Operating hour Oil pressure (psi, kPa or bar) Coolant temperature (OEC or OEF) DC Volts Oil Temperature (OEC or OEF) L-L Volts, L-N Volts, Phase amps Average volts, Amps, Frequency ekW, kVa, kVAR, kW-hr, % kW, Power Factor (Average, Phase) kW-hr, kVA-hr (total) Warning/Shutdown with indicating lights for: Low oil pressure High coolant temperature Overspeed Emergency stop Failure to start (overcrank) Low coolant level High oil temperature Programmable Protective Relaying Functions Phase over/under Voltage Under and Over Frequency Reverse Power Current Balance Over Current (Phase and Total) Loss of Excitation Bus Phase Sequence Modes of operation Single Unit Island Mode Multiple Unit Island Mode - Automatic and Manual Paralleling Single Unit Utility Parallel Mode - Automatic and Manual Paralleling Paralleling Functions Load sharing Load sense/Load demand Load Shed/Load add Dead bus arbitration Synchronizing TRAILER Anti-lock Brake System Air Ride Two Axle, 48- ISO container chassis
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/c8b189970dc140ae8117e3f6e71aa289/view)
 
Place of Performance
Address: Daytona Beach, FL 32117, USA
Zip Code: 32117
Country: USA
 
Record
SN06686377-F 20230519/230517230113 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.