Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 19, 2023 SAM #7843
SOURCES SOUGHT

23 -- MRI Trailer

Notice Date
5/17/2023 10:59:44 AM
 
Notice Type
Sources Sought
 
NAICS
336212 — Truck Trailer Manufacturing
 
Contracting Office
260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98662 USA
 
ZIP Code
98662
 
Solicitation Number
36C26023Q0379
 
Response Due
5/26/2023 12:00:00 PM
 
Archive Date
06/25/2023
 
Point of Contact
Robert Hamilton, Contracting Officer, Phone: 360-852-9880
 
E-Mail Address
robert.hamilton8@va.gov
(robert.hamilton8@va.gov)
 
Awardee
null
 
Description
Sources Sought The purpose of this Sources Sought Announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), Small Business Manufacturers, other Small Businesses interested and capable of providing items requested, as well as any large businesses. The results from this source sought notice will be used to determine set-aside. The intended contract is a firm-fixed price supply purchase. The SBA Non-Manufacturer Rule is not applicable. The Department of Veterans Affairs, NCO20 is looking for sources of the following: Item Qty 12x60 foot new MRI transportable unit built to the specifications of the GE Signa Voyager 1.5T MRI system. 1 Minimum 1-year parts and labor warranty 1 Salient Characteristics: All specifications of this Magnetic Resonance Imaging (MRI) transport trailer must follow all manufacturer s (GE) (OEM) requirements and all applicable safety regulations. Coordination with the manufacturer is critical during the installation of the MRI machine into the trailer. Essential/significant physical, functional, or performance characteristics. MRI Trailer Overall length: 60 Overall height: 13 -6 Overall width: 12 Custom Chassis: Custom built dual twin I-beam flat floor aluminum chassis Four (4) fixed jack stands for rear of trailer Two (2) manual landing legs with pins located in the front of the trailer All aluminum wheels and radial tires Air ride suspension Spread axle with air ride rear suspension Anti-lock brakes Custom Body: Wall construction to include aluminum tube Magnetic steel shielding per OEM requirements for VA Puget Sound specific 1.5T MRI system to be integrated into unit. Gauss line will be maintained below 5 gauss at any point beyond 6 from any side wall Exterior sheet 0.50 raw aluminum Entire unit painted white Polyurethane spray foam insulation between tubes to provide barrier to heat, cold and noise Vapor barrier installed on floor of trailer to resist moisture Drip rails over main entry door and all along the top of the unit Mirror image orientation with entry doors located on the driver s side of the unit Exterior Features All aluminum lower belly box compartment area. To include lockable storage with aluminum insulated doors and gas cylinders Staff entry door and stairs for direct access to unit Bubble levels mounted on the unit Swinging door (into MRI trailer) to allow for unit to connect to Zone 2 MRI trailer Vinyl skirting around perimeter of unit to protect exposed areas to the elements Steel combination lockbox mounted on the front of the trailer for key storage General Layout Unit will meet all specifications that the MRI OEM has developed regarding the siting and installation of their MRI system into a transportable unit Mirror image orientation MRI scan room at the rear of the unit Technologist control room in the middle of the unit Linen storage area with shelves for clean and soiled linen Swing door to allow for direct connection between zone 2 MRI trailer and MRI trailer Front equipment room for OEM computer equipment and transportable support systems including electrical and HVAC systems Flooring Plates to mount system and equipment in Scan Room and equipment room. Single piece vinyl flooring throughout entire trailer to include plywood sub flooring Walls, Cabinets and Counter Tops Solid surface countertops in Scan Room and Control Room Cabinetry located in the Scan Room and Control Room Coil and phantom storage in scan room Walls to be built with hospital grade wall covering for ease of cleaning and longevity Ceiling and Lighting Fully dimmable LED lights to be provided throughout the trailer Sound reducing drop ceiling with acoustical ceiling tiles Ceiling to include A/C louvers for proper dispersion of air flow Separate lighting controls located in each room Magnetic Shielding Shielding per manufacturers specifications in the Scan Room on each wall and the back of the unit where the rear door is located Gauss field will be maintained below 5 at all points 6 away from outside walls 44 wide pneumatic scan room door RFI Shielding Aluminum RFI shielding lightweight and non-oxidizing. Installed to the specifications of the system manufacturer. Third party RFI testing company to confirm compliance RF Windows Window between the Control Room and Scan Room is designed for ease of viewing but also RFI compliance Auto fogging capability for privacy Communications Three (3) Phone, fax, and Seven (7) data connection conveniently located in Control Room and lower compartment. (2) 15.24m Hubbell Data cords and (1) Phone cord supplied with unit. Electrical Requirements Main 480 Volt AC disconnect for system located in lower compartment Electrical distribution panel located in Equipment Room to allow for ease of serviceability and maintenance 480-volt, 3 phase power Shore power cable provided in the underbelly storage compartment 12-volt DC charger/inverter provided Interior Emergency lighting installed to provide illumination when the unit has lost power DC power supply in belly box area along with another power supply for the battery charger 45kw on board generator to provide emergency back-up power in the event of power loss. Generator provides sufficient power to run cold head to prevent helium loss, HVAC system, and transportable lights Automatic Transfer Switch that starts generator if shore power supply is interrupted The generator does not provide sufficient power to support scanning operations Air Conditioning/Heating Northern Air combination HVAC/Chiller system mounted at the front top of the transportable unit. This system provides both environmental heating and cooling as well as all chilled water requirements for the MRI system. NOTE: This system eliminates the need for an OEM supplied external chiller Separate air supplies to go to the different rooms Louvers in the ceiling are designed for minimum downdrafts but still maintain proper air flow throughout the unit Thermostats are set at out facility before shipping to maintain proper temperature Miscellaneous AM/FM stereo receiver with CD and iPOD interface installed in Control Room. Speakers to be installed in unit Site Planning Guide to be provided at time of deposit received Manuals for all components to be provided on board unit at time of delivery Fire extinguishers, handheld ABC all purpose, located in each room Fire suppression system (Dry System) Code Blue Alert System Nurse Call Alert System Prep for customer supplied patient injector Install customer supplied patient injector Sky Factory Sky light 6 x4 over MRI Table in scan room Wall mural in scan room Medical Gas Outlets: 02/Air/Suction; Provide outlets in the scan room and outlets in the underbelly compartment Wave guide pass through scan room wall Custom candy cane quench vent MRI install coordination between OEM and trailer manufacture needed Rigging support to OEM installation team during mechanical installation process at trailer company production facility Transportation to Everett CBOC Warranty: Minimum 1-year parts and labor warranty Potential contractors shall provide, at a minimum, the following information to robert.hamilton8@va.gov. 1) Company name, address, and point of contact, phone number, e-mail address, and DUNS. 2) Please identify your company s size in comparison to the anticipated North American Industry Classification System (NAICS) code 336212 Truck Trailer Manufacturing. To be considered a small business your company must have fewer than 1000 employees. This notice is to determine the marketplace for this specific requirement. Please check one of the following: [ ] yes [ ] no Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no Veteran Owned Small Business (VOSB) [ ] yes [ ] no Small Business Manufacturers [ ] yes [ ] no All other Small Business (SB) [ ] yes [ ] no Other than Small Business 3) The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought notice. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Notice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System Award Management (SAM located on the web at www.sam.gov). It is desirable that any Offeror to have completed their business Online Representations and Certifications Application in the System for Award Management (SAM). 4) Any Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must provide a SBA certification and be registered with U.S. Small Business Administration Veteran Small Business Certification (VetCert) located at https://veterans.certify.sba.gov/. 5) If not a manufacturer, only authorized representatives/providers/distributors of the manufacturer will be considered. Equipment must be new, no used or refurbished equipment accepted. Please provide a proof of authorized dealer or reseller letter from manufacturer. 6) This is a brand name or equal requirement. As such, the salient characteristics reflect the physical, functional, or performance characteristics that equal products must meet to satisfy the Government s needs. To be considered for any potential solicitation, offers of equal products, including equal products of the brand name manufacturer, must: (a) Meet the salient physical, functional, or performance characteristic specified in this sources sought; clearly identify the item by Brand name, if any and make/model number. (b) Include descriptive literature such as illustrations, drawings, or a clear reference to descriptive data or information available that identifies that the equal item meets or exceeds the salient characteristics required by the Government. (c) Please provide a courtesy quote in response to this request to evaluate price reasonableness for any set-aside determination. (d) Please identify the country of origin for all items. Responses are due by 05/26/2023 3:00 PM EST, to the Point of Contact. Shipping Address: Everett Veterans Center 1010 SE Everett Mall Way #207 Everett, WA 98201 Point of Contact: Robert Hamilton Contracting Officer robert.hamilton8@va.gov
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/c149c82518334282bcf7ca810442bf1d/view)
 
Place of Performance
Address: Everett Veterans Center 1010 SE Everett Mall Way #207, Everett, WA 98201, USA
Zip Code: 98201
Country: USA
 
Record
SN06686317-F 20230519/230517230113 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.