Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 13, 2023 SAM #7837
SOLICITATION NOTICE

65 -- GE OEC 9900 Digital C-Arm

Notice Date
5/11/2023 11:03:19 AM
 
Notice Type
Presolicitation
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
NATIONAL INSTITUTES OF HEALTH - CC BETHESDA MD 20892 USA
 
ZIP Code
20892
 
Solicitation Number
23-002167
 
Response Due
5/16/2023 9:00:00 AM
 
Point of Contact
Noelle DeCenzo, Phone: 3013518422
 
E-Mail Address
noelle.decenzo@nih.gov
(noelle.decenzo@nih.gov)
 
Description
This is a notice of intent, not a request for a quotation. A solicitation document will not be issued and quotations will not be requested. The National Institutes of Health (NIH) intends to award a fixed price contract to GE HEALTHCARE, on a sole source basis to provide GE OEC 9900 Digital C-Arm at the NIH Clinical Center (CC). The Clinical Center requires GE OEC Digital C-Arm with vascular platform for intraoperative imaging suited for a range of surgical needs including vascular, orthopedics, gastrointestinal, endoscopic, urological, neurological, critical care, pain management, and emergency procedures.� GE is the only vendor that met NIH requirements, particularly with the largest field of view (FOV) and significant dose advantages to the patient, and staff, since the x ray tube is under the table, everyone receives less scatter radiation. C-Arm also had greater range of patient procedures and increased patient access and, if mobile imaging system fails, another system can be brought into room. Protocol based care requires Inconsistent equipment, features, interfaces, supplies and operations will prevent researcher�s absolute consistency and reproducibility in equipment and processes.� GE OEC is the only brand with a single line of products that meets the requirements needed for this contract. No other brand can provide: o����������� CMOS Flat Detector (CFD) 31cm size field of view (FOV) o����������� Detailed full frame rate and full resolution pixel conversion with 32� 4K UHD display o����������� Live Zoom up to 4X and take added shots with no change in technique o����������� Ability to outline (live zoom) anatomy of interest or device (stent) on image screen with Digital Pen on both displays o����������� Linux-based operating system brings another layer of security (longer support and more security) o����������� Articulating monitor (monitoring cart) has 5 ranges of motion including 27� forward travel which increases the perceived size of the image by up to 60% o����������� Set up efficiently with SmartConnect.(operate C-Arm and monitoring cart independently). Disconnect and reconnect the C-arm and workstation while booted o����������� 13.6� Square circle image retains 100% data when image is rotated (22% more anatomy view with larger FOV) o����������� 0.008� guidewires in peripheral vessels and 0.014� guidewires in thoracic anatomy o����������� Real time true continuous fluoroscopy that minimizes ghosting and lag o����������� Ergo C-arm�s SmartView pivot joint enables additional angles and positions without moving the C-arm base o����������� Regulate heat with split-block design that separates the X-ray tube and generator (not monoblock) o����������� Great visual line of sight and positioning around the patient based on small detector head size o����������� Agile maneuvering around patient with low lateral height and small tube housing o����������� Synchronize surgical workflow and communication, with mirrored view from OEC Touch (Tech View) and workstation o����������� Manage dose with six dose control modes that can be used independently or in combination As such, no other vendor is capable of providing the Government with the C-Arm.� This acquisition is being conducted using policies unique to the Federal Acquisition Regulation (FAR) Part 13 � Simplified Acquisition Procedures, Subpart 13.106-1(b)(1), For purchases not exceeding the simplified acquisition threshold (SAT), contracting officers may solicit from one source if the contracting officer determines that the circumstance of the contract action deem only one source reasonably available.� Contracts awarded using FAR Part 13-Simplified Acquisition Procedures are exempt from the requirements of FAR Part 6-Competition Requirements. Interested parties may identify their interest and capabilities in response to this posting. The determination by the Government not to compete the proposed requirement based upon responses to this notice is solely within the discretion of the Government. Comments to this announcement, referencing this posting number, may be submitted to the CC, Office of Purchasing and Contracts, prior to the closing date specified in this announcement, electronically to the attention of Noelle DeCenzo, Contract Specialist, noelle.decenzo@nih.gov by the due date and time marked in this notice.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/f9970fb0157e409d98f76b590bec512d/view)
 
Place of Performance
Address: Bethesda, MD 20892, USA
Zip Code: 20892
Country: USA
 
Record
SN06680131-F 20230513/230511230112 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.