MODIFICATION
65 -- 619-23-2-490-0203 CHAIRS PATIENT TRANSFER (VA-23-00050232)
- Notice Date
- 4/26/2023 10:19:14 AM
- Notice Type
- Sources Sought
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- 247-NETWORK CONTRACT OFFICE 7 (36C247) AUGUSTA GA 30904 USA
- ZIP Code
- 30904
- Solicitation Number
- 36C24723Q0539
- Response Due
- 5/1/2023 11:00:00 AM
- Archive Date
- 08/08/2023
- Point of Contact
- Rudy A Cortinez, Contract Specialist, Phone: (770) 279-3414
- E-Mail Address
-
rudy.cortinez@va.gov
(rudy.cortinez@va.gov)
- Awardee
- null
- Description
- Request for Information 36C24723Q0539 Power Recliner Transport Chair with Swing Away Arms This is a source sought notice for information and planning purposes only and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs (VA). The VA is currently conducting market research to locate qualified, experienced, and interested potential small business, service-disabled veteran owned small business and veteran owned small business sources. NAICS 339113 (size standard: 750 employees) applies. The Veterans Health Administration (VHA) is seeking interested sources (contractors) for a near future solicitation and procurement of Recliner Transporter Power with Swing Away Arms at Central Alabama VA Medical Center in Montgomery Alabama. The items should be delivered in a timely manner as outlined later. If a solicitation is issued it will be announced at a later date, and all interested parties must respond to that solicitation announcement separately from this response. Responses to this source sought is not a request to be added to a prospective bidder list or to receive a copy of the solicitation. Information received as a result of this notice will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. This notice does not represent a commitment by the Government to pay for costs incurred in the preparation and submission of information or any other costs incurred as a response to this announcement. Please forward all responses to point of contact, Rudy A. Cortinez at rudy.cortinez@va.gov, if you are interested and capable of providing the requested items by the 2:00 pm EST on May 01, 2023. See attached document: Salient Characteristics/Specifications POWER RECLINER TRANSPORT CHAIRS SALIENT CHARACTERICS SPECIFICATIONS: Hand-held remote Swing-away arms 3 casters Wall-hugger mechanism infinite recline positions) All Steel, powder-coated frame Quick-release seat Push handle for medical recliners factory installed O2 Tank Holder Right Side Swing Arms Technical Specifications for Power Recliner/Transporter with Swing-Away Arms Trendelenburg: 74"" Depth Arm Height From Floor (Back): 24.5"" Arm Height From Floor (Front): 27.5"" Overall Width (Two Tables Down): 32"" Overall Width (Two Tables Up): 52"" Back Height From Floor: 46"" Back Height From Seat: 29"" Seat Depth: 18"" Seat Height: 21"" Casters: 3"" Color: Colonial Blue Weight capacity: 300 pounds Includes: Swing-Away Arms, Thermo-Sensitive Seat Foam, Quick-Release Seat, Wall-Hugger Design
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/3f2655aafc924bfc9bbe891c12400363/view)
- Record
- SN06662683-F 20230428/230426230104 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |