Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF FEBRUARY 17, 2023 SAM #7752
SOLICITATION NOTICE

59 -- 59--CABLE ASSEMBLY,SPEC

Notice Date
2/15/2023 12:55:45 AM
 
Notice Type
Solicitation
 
NAICS
333998 —
 
Contracting Office
NAVSUP WEAPON SYSTEMS SUPPORT MECH MECHANICSBURG PA 17050-0788 USA
 
ZIP Code
17050-0788
 
Solicitation Number
N0010422QFF92
 
Response Due
3/7/2023 12:30:00 PM
 
Archive Date
03/22/2023
 
Point of Contact
Telephone: 7176051234
 
E-Mail Address
SYLVIA.SENTZ@NAVY.MIL
(SYLVIA.SENTZ@NAVY.MIL)
 
Description
CONTACT INFORMATION|4|N743.45|CFA|717-605-3353|sylvia.sentz@navy.mil| ITEM UNIQUE IDENTIFICATION AND VALUATION (MAR 2022)|19|||||||||||||||||||| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| TIME OF DELIVERY (JUNE 1997)|20|0001|141|500 days|||||||||||||||||| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (DEC 2018)|16|Stand-Alone Receiving Report - Certifications Combo-Receiving Report & Invoice - Material|n/a|tbd|N00104|tbd|tbd|see schedule|tbd|n/a|n/a|n/a|n/a|n/a|n/a|n/a|n/a| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|| EQUAL OPPORTUNITY (SEP 2016)|2||| WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003)|6|one year from date of delivery|one year from date of delivery||||| WARRANTY OF DATA--BASIC (MAR 2014)|2||| FIRST ARTICLE APPROVAL--CONTRACTOR TESTING (SEP 1989)|10|1|0001AA|7|180|tbd|tbd|0001AA|60|x|| BUY AMERICAN --FREE TRADE AGREEMENTS--BALANCE OF PAYMENTS PROGRAM - BASIC(DEVIATION 2020-O0019) (MAR 2022))|3|||| NOTICE OF TOTAL SMALL BUSINESS SET-ASIDE (OCT 2020)(DEVIATION 2020-O0008)|1|| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (NOV 2020)|13|||||||||||||| SMALL BUSINESS PROGRAM REPRESENTATIONS (DEVIATION 2023-O0002) (DEC 2022)|4||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE (DEVIATION 2020-O0019) (JUL 2020))|3|||| BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (NOV 2014)|1|| ANNUAL REPRESENTATIONS AND CERTIFICATIONS (MAY 2022)|13|335931|500|||||||||||| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||x| 1. Drawings associated with this solicitation will be made available on theSAM.gov website but will be restricted access, which needs to be approved. Once access has been requested, interested vendors should email the POC listed on the solicitation to inform them of the request. 2. NAVSUP WSS Mech will be considering past performance in the evaluation ofoffers. See Clause 252.213-7000. 3. All contractual documents (i.e. contracts, purchase orders, task orders,delivery orders and modifications) related to the instant procurement areconsidered to be ""issued"" by the Government when copies are either deposite in the mail, transmitted by facsimile, or sent by other electronic commercemethods, such as email. The Government's acceptance of the contractor'sproposal constitutes bilateral agreement to ""issue"" contractual documents asdetailed herein. 4. This requires First Article Testing. See FAR 52.209-3 First Article Approval Contractor Testing for more details. 5. This requirement requires access to Confidential drawings. These drawingsare not required to provide a quotation for the RFQ/RFP. However, in the event of an award, a facility security clearance is required. 6. This requirement is issued pursuant to Emergency Acquisition Flexibilities. \ 1. SCOPE 1.1 This contract/purchase order contains the requirements for manufacture and the contract quality requirements for the CABLE ASSEMBLY,SPEC . 2. APPLICABLE DOCUMENTS 2.1 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions. 2.1.1 Documents, drawings, and publications supplied are listed under ""Drawing Number"". These items should be retained until an award is made. 2.1.2 ""Document References"" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order. 2.2 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order shall take precedence. Nothing in this contract/purchase order, however, shall supersede applicable laws and regulations unless a specific exemption has been obtained. DRAWING DATA=15252 |10001| -|WS |D|0000.I | -|49998|0017894 DRAWING DATA=15252 |10001| -|WS |D|0000.II | -|49998|0022083 DRAWING DATA=15252 |10001| -|WS |D|0001 | -|49998|0022449 DRAWING DATA=15252 |10001| -|WS |D|0002 | -|49998|0039075 DRAWING DATA=15252 |10001| -|WS |D|0003 | -|49998|0039563 DRAWING DATA=15252 |10001| -|WS |D|0004 | -|49998|0032743 DRAWING DATA=15252 |10001| -|WS |D|0005 | -|49998|0035391 DRAWING DATA=15252 |10001| -|WS |D|0006 | -|49998|0041103 DRAWING DATA=15252 |10001| -|WS |D|0007 | -|49998|0040455 DRAWING DATA=15252 |10001| -|WS |D|0008 | -|49998|0036962 DRAWING DATA=15252 |10001| -|WS |D|0009 | -|49998|0054705 DRAWING DATA=2505790 |10001| E|FN |D|0001 | E|49998|0055085 DRAWING DATA=2505791 |10001| E|FN |D|0001 | E|49998|0056184 DRAWING DATA=2507660 |10001| J|FN |D|0001 | J|49998|0087605 DRAWING DATA=2508929 |10001| D|FN |D|0001 | D|49998|0056875 DRAWING DATA=5727489 |53711| R|FN |D|0001 | R|49998|0196266 DRAWING DATA=5727490 |53711| Y|FN |D|0001 | Y|49998|0345813 DRAWING DATA=5894148 |53711| J|DOC|D|0001 | |49998|0213481 DRAWING DATA=5906555 |53711| G|FN |D|0001 | |49998|0273323 DRAWING DATA=5906556 |53711| B|FN |D|0001 | B|49998|0052778 DRAWING DATA=6105225 |53711| D|FN |D|0001 | D|49998|0053443 DRAWING DATA=6105238 |53711| D|FN |D|0001 | D|49998|0055291 DRAWING DATA=6105298 |53711| N|FN |D|0001 | |49998|0143117 DRAWING DATA=6105298 |53711| M|PL |D|0001 | M|49998|0027127 DRAWING DATA=6105310 |53711| B|FN |D|0001 | B|49998|0049123 DRAWING DATA=6105311 |53711| D|FN |D|0001 | |49998|0059804 DRAWING DATA=6105323 |53711| C|FN |D|0001 | C|49998|0060916 DRAWING DATA=6105330 |53711| E|FN |D|0001 | E|49998|0057745 DRAWING DATA=6105331 |53711| D|FN |D|0001 | D|49998|0056386 DRAWING DATA=6239880 |53711| C|FN |D|0001 | C|49998|0181784 DRAWING DATA=6239881 |53711| A|FN |D|0001 | A|49998|0038710 DRAWING DATA=6239881 |53711| A|FN |D|0002 | A|49998|0025455 DRAWING DATA=6239881 |53711| A|FN |D|0003 | A|49998|0029623 DRAWING DATA=6239881 |53711| A|FN |D|0004 | A|49998|0022958 DRAWING DATA=6239881 |53711| A|FN |D|0005 | A|49998|0026582 DRAWING DATA=6239881 |53711| A|FN |D|0006 | A|49998|0025696 DRAWING DATA=6239881 |53711| A|FN |D|0007 | A|49998|0027845 DRAWING DATA=6239881 |53711| A|FN |D|0008 | A|49998|0022382 DRAWING DATA=6239882 |53711| A|FN |D|0001 | A|49998|0038669 DRAWING DATA=6239882 |53711| A|FN |D|0002 | A|49998|0026068 DRAWING DATA=6239882 |53711| A|FN |D|0003 | A|49998|0027259 DRAWING DATA=6239882 |53711| A|FN |D|0004 | A|49998|0029032 DRAWING DATA=6370928 |53711| A|FN |D|0001 | A|49998|0113604 DRAWING DATA=6370928 |53711| A|FN |D|0002 | A|49998|0073756 DRAWING DATA=6370928 |53711| A|FN |D|0003 | A|49998|0087005 DRAWING DATA=6370928 |53711| A|FN |D|0004 | A|49998|0074493 DRAWING DATA=6370928 |53711| A|FN |D|0005 | A|49998|0089297 DRAWING DATA=6370928 |53711| A|FN |D|0006 | A|49998|0085026 DRAWING DATA=6370928 |53711| A|FN |D|0007 | A|49998|0074676 DRAWING DATA=6370928 |53711| A|FN |D|0008 | A|49998|0036940 DRAWING DATA=6370928 |53711| 1|1N |D|0001 | 1|49998|0085282 DRAWING DATA=6370928 |53711| 1|1N |D|0002 | -|49998|0039017 DRAWING DATA=6370928 |53711| 1|1N |D|0003 | -|49998|0028306 DRAWING DATA=6370928 |53711| 1|1N |D|0004 | -|49998|0037480 DRAWING DATA=6370928 |53711| 1|1N |D|0005 | -|49998|0034739 DRAWING DATA=6370928 |53711| 1|1N |D|0006 | -|49998|0033302 DRAWING DATA=6370928 |53711| 1|1N |D|0007 | -|49998|0024011 DRAWING DATA=6657093 |53711| A|FN |D|0001 | A|49998|0071141 DOCUMENT REF DATA=MIL-STD-129 | | |P |041029|A| |03| DOCUMENT REF DATA=ISO9001 | | | |010417|A| | | DOCUMENT REF DATA=MIL-STD-973 | | | |950113|A| |03| 3. REQUIREMENTS 3.1 Design, Manufacture, and Performance - Except as modified herein, the CABLE ASSEMBLY,SPEC furnished under this contract/purchase order shall meet the design, manufacture, and performance requirements specified on drawing ;6105298; cage ;53711; . 3.2 Marking - This item shall be physically identified in accordance with ;MIL-STD-129; . 3.3 Configuration Control - MIL-STD-973 entitled ""Configuration Management"", Paragraph 5.4.8, Configuration Control (Short Form Procedure), is hereby incorporated. The Contractor shall submit all Engineering Change Proposals in accordance with MIL-STD-973, Paragraph 5.4.8.2 and Appendix D. Requests for Deviations shall be processed in accordance with MIL-STD-973, Paragraph 5.4.8.3 and Appendix E. Requests for Waivers shall be processed in accordance with MIL-STD-973, Paragraph 5.4.8.4 and Appendix E. (Original and two copies shall be submitted to Contracting Officer, NAVICP-MECH, P. O. Box 2020, Mechanicsburg Pa. 17055-0788.) 3.3.1 Configuration Control - When the Contractor has received authorization on a prior contract for the same NSN for the use of a drawing of a later revision status, that authorization is hereby extended to all succeeding contracts/purchase orders until another drawing revision is approved. The Contractor will notify the PCO of this occurrence in each instance, in the response to the solicitation. Such notification shall be in writing setting forth the contract under which the prior authorization was granted, the date of the granting of the authorization, and the name of the granting authority. Contractors shall also refer technical inquiries (other than those covered by MIL-STD-973) on company letterhead signed by a responsible company official, with copies distributed as stated below. The original and two copies of all Contractor generated correspondence regarding configuration shall be submitted to Contracting Officer, NAVICP-MECH, P.O. Box 2020, Mechanicsburg, PA 17055-0788. Contractors are cautioned that implementing engineering changes, waivers, deviations or technical inquiries into the contract/purchase order without approval of the Contracting Officer will be at the sole risk of the Contractor. 3.4 Mercury Free - The material supplied under this contract/purchase order is intended for use on submarines/surface ships and therefore shall contain no metallic mercury and shall be free from mercury contamination. Mercury contamination of the material will be cause for rejection. If the inclusion of metallic mercury is required as a functional part of the material furnished under this contract, the Contractor shall obtain written approval from the Procurement Contracting Officer before proceeding with manufacture. The contractor's request shall explain in detail the requirements for mercury, identify specifically the parts to contain mercury, and explain the method of protection against mercury escape. Such a request will be forwarded directly to the Procurement Contracting Officer with a copy to the applicable Government Inspector. Upon approval by the Contracting Officer, the vendor will provide a ""Warning Plate"" stating that metallic mercury is a functional part of the item and will include name and location of that part. The use of mercury, mercury compounds, or mercury-bearing instruments and/or equipment in a manner which might cause contamination in the manufacture, assembly, or test of material on this contract is prohibited. The most probable causes of contamination are direct-connected manometers, mercury vacuum pumps, mercury seals, or the handling of mercury in the immediate vicinity. Mercury switches, mercury in glass thermometers, standard cells and other items containing mercury may be used if they are located so as not to constitute a contamination hazard. If external contamination by metallic mercury occurs or is suspected, the following test may be used to determine whether contamination by metallic mercury exists or whether corrective cleaning measures have been effective. Enclose the equipment in a polyethylene bag or close-fitting airtight container for eight hours at room temperature (70 degrees F minimum).Sample the trapped air and if mercury vapor concentration is 0.01 mg/cu meter or more, the material is mercury contaminated insofar as the requirements of this contract are concerned. These requirements shall be included in any subcontract or purchase order hereunder and the Contractor shall insure SubContractor compliance with these requirements. Technical questions pertaining to these requirements shall be referred to the Procurement Contracting Officer via the cognizant Administrative Contracting Officer. For background, the following information is provided: Mercury is corrosive to gold, silver, nickel, stainless steels, aluminum and copper alloys. Stainless steels, nickel, and copper alloys are widely used in reactor plants and other submarine/surface ship systems. Accidental trapping of mercury in a component could cause serious damage to vital parts. Mercury is also toxic if inhaled, ingested, or absorbed through the skin. It is evident that grave consequences could result from small amounts of mercury vapor present in an unreplenished submarine/surface ship atmosphere. 3.5 First Article Approval (Contractor Testing) - First Article Test (FAT) and approval is required. 3.6 Security Clearance Required - This contract/purchase order requires the Contractor to have a Government Security Clearance in accordance with the attached Contract Security Classification Specification (DD Form 254). 3.6.1 ;DD254 is required IAW DWG 5894148 rev ""J"" para 3.2.1.1 5759651 - (C) PRESSURE TESTS (U) (This document is classified, vendor will need security clearance).; 3.7 Serialization - The supplier shall mark a serial number on each CABLE ASSEMBLY,SPEC in accordance with ;IAW DWG 6105298 rev ""N"".; . Actual serial numbers will be assigned ;Serial numbers are obtained from NUWC Newport by sending email request to: NUWC_NPT_SERIALNUMBERS@NAVY.MIL; . 3.8 Production Lot Approval (Contractor Testing) - Production Lot Test and approval is required. ;Contractors, pay special attention to key requirements. Drawing 6105298 Key Features: Notes 3, 11, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23,24, 25, and 30. Drawing 5906555 (Requirements for Bulk Cable) KeyFeatures: Notes 2.1, 4.5, 4.6, 5, and 6. (6.3.1, 6.4.1 & 6.4.2)Drawing 6105323 (Molding Compound) Key Features: Notes 1, 2 (2.1, 2.2, 2.2.2, 2.2.3), 3 (3.1, 3.2, &3.3),and 4 (4.1 & 4.2) Drawing 2508929 (Connector, Cable Connecting - AlteredItem MS3110E8-4S) Key Features: Note 3 Drawing 2505791 (Connector, Slide Valve Cable - AlteredItem MS3110E8-4PW) Key Features: Note 3 Drawing 2505790 (Connector, Speed Control Cable -Altered Item MS3110E8-4P) Key Features: Note 2 Drawing 6105238 (Backshell) Key Features: Note 3 Drawing 5906556-14 (Connector, Plug High PressureUnderwater - Altered Item 5727489-14) Key Features: Note 3 Drawing 5727489-14 (Connector, Plug High PressureUnderwater - Source Control) Key Features: Notes 1, 2, 4, 5 and 14, 6, 7, 8, 12, 13, 15, 19 and 21, and 20. Drawing 6105225 (Backshell Cap) Key Features: Note 3 Drawing 6105331 (Backshell) Key Features: Notes 3 and 5. Drawing 6105330 (Backshell) Key Features: Notes 3 and 5. ; 4. QUALITY ASSURANCE 4.1 Responsibility for Inspection - Unless otherwise specified in the contract/purchase order, the Contractor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract/purchase order, the Contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. 4.2 Quality System Requirements - The supplier shall provide and maintain a quality system acceptable to the Government. The quality system requirements shall be in accordance with ISO 9001. 4.2.1 ;Suppliers currently using and maintaining Inspection System Requirements to MIL-I-45208 are granted permission to utilize this if desired.; 4.3 Responsibility for Compliance - All items must meet all requirements of this contract/purchase order. The inspection set forth in this specification shall become a part of the Contractor's overall inspection system or quality program. The absence of any inspection requirements shall not relieve the Contractor of the responsibility of assuring that all products or supplies submitted to the Government for acceptance comply with all requirements of the contract/purchase order. Sampling in quality conformance does not authorize submission of known defective material, either indicated or actual, not does it commit the Government to acceptance of defective material. 4.4 Records of Inspection - (This requirement is not applicable to Government Purchase Orders) Records of all inspection work performed by the Contractor, as referenced elsewhere in this contract, shall be kept complete and available to the Government during the performance of the contract and for a period of four years after final delivery of supplies. 4.5 First Article Test/Inspection (Contractor) - The Contractor shall conduct ;CRITICAL ITEM PRODUCTION FABRICATION SPECIFICATION DRAWING 5894148 REV J.; First Article Test/Inspection on ;2 ; unit(s) in accordance with requirements ;Paragraph 3.2.1.1 Paragraph 3.2.1.3 and 4.2.4.3 ; . 4.6 Production Lot Test (Contractor) - The Contractor shall perform 100% production testing in accordance with ;Production Lot Test IAW DWG 5894148 J. 4.2 Quality conformance inspections Paragraphs 3.4.1, 3.4.2, 4.2.1.1 and 4.2.1.2 ; . 4.7 Production Lot Test (Contractor) - The Contractor shall perform Production Lot Testing in accordance with ;IAW DWG 5894148 REV J. Preproduction Sample - A preproduction sample of two (2) each of the5W1, 5W2, 5W7 and 5W8 Cable Assemblies shall be manufactured using themethods and procedures proposed for production. The sample shall be tested as specified in specification 53711-5894148, Section 4, for the purpose of determining that thecontractor, prior to starting production,is capable of producing items that comply with the design and the technical requirements of the contract. If, after submission of the preproduction sample, a design change is made to the Cable Assembly sufficient to affect its safety, life, or operational characteristics, or substantially altered facilities are used in production, a new preproduction sample shall be manufactured by the contractor and tested as specified in specification 53711-5894148, Section 4. In-water /Dynamometer Test: Cable Assemblies being supplied by new vendors for qualification efforts or Cable Assemblies with major design changes will be subjected to in-water test runs and/or dynamometer test runs and becapable of satisfying all performance requirements. The types and number of in-water test runs and/or dynamometer test runs will be determined, on an individual case basis, by the Government. The requirement for in-water testruns and/or dynamometer test runs may be waived, on an individual case basis,at the option of the Government.(This system level testing is conducted by the Government.); . 4.8 Quality Conformance Inspection - The contractor is responsible for conducting a Quality Conformance Inspection in accordance with ;Quality Conformance Inspection IAW DWG 5894148 Rev J paragraph 4.2; , paragraph ;Paragraph 4.2.1.3 Documentation. ; and preparing an inspection report in accordance with the Contract Data Requirements List, DD Form 1423. 5. PACKAGING 5.1 Preservation, Packaging, Packing and Marking - Preservation, Packaging, Packing and Marking shall be in accordance with the Contract/Purchase Order Schedule and as specified below. MIL-STD 2073 PACKAGING APPLIES AS FOUND ELSEWHERE IN THE SCHEDULE 6. NOTES 6.1 Ordering Information for Document References - The Department of Defense Single Stock Point (DODSSP), Website http://www.dsp.dla.mil/, provides product information for the Department Of Defense Index Of Specifications and Standards (DODISS) (i.e.Military/Federal Specifications and Standards), Data Item Descriptions (DIDs), and other DODSSP Products. A. Availability of Cancelled Documents - The DODSSP offers cancelled documents that are required by private industry in fulfillment of contractual obligations in paper format. Documents can be requested by phoning the Subscription Services Desk. B. Commercial Specifications, Standards, and Descriptions - These specifications, standards and descriptions are not available from Government sources. They may be obtained from the publishers of the applicable societies. C. Ordnance Standards (OS), Weapons Specifications (WS), and NAVORD OSTD 600 Pages - These type publications may be obtained by submitting a request to: Commander, Indian Head Division, Naval Surface Warfare Center Code 8410P, 101 Strauss Avenue Indian Head, MD 20640-5035 D. On post-award actions, requests for ""Official Use Only"" and ""NOFORN"" (Not Releasable To Foreign Nationals) documents must identify the Government Contract Number, and must be submitted via the cognizant Defense Contract Management Command (DCMC) for certification of need for the document. On pre-award actions such requests must be submitted to the PCO for certification of need for the document. E. NOFORN Military Specifications and Standards (including Amendments, Change Notices and Supplements, but NOT interim Changes) to be ordered from: Contracting Officer NAVICP-MECH Code 87321 5450 Carlisle Pike P.O. Box 2020 Mechanicsburg, Pa. 17055-0788 F. Nuclear Reactor Publications Assigned NAVSEA Documents and Identification Numbers (i.e. NAVSEA Welding Standard, NAVSEA 250-1500-1) are to be ordered from: Commanding Officer NAVICP-MECH Code 009 5450 Carlisle Pike P.O. Box 2020 Mechanicsburg, Pa. 17055-0788 G. Technical Manuals Assigned NAVSEA Identification Numbers (i.e. NAVSEA Welding And Brazing Procedure, NAVSEA S9074-AQ-GIB-010/248) are to be ordered from: Naval Inventory Control Point Code 1 Support Branch 700 Robbins Avenue Phildelphia, Pa. 19111-5094 H. Interim Changes and Classified Specifications shall be obtained by submitting a request on DD Form 1425 to NAVICP-MECH. 6.2 ;QUALITY ASSURANCE PROVISIONS (QAPs) is available on NAVSUP WSS share drive for DWG 6105298. S: MECH NAVICP ICPM WSS General Shares N97 General Shares N9713 Technical Torpedo (QAPs) QUALITY ASSURANCE PROVISIONS QAP Final ; DATE OF FIRST SUBMISSION=030 DAC ;53711-5759651 - (C) PRESSURE TESTS (U)5894148 para 3.2.1.1: The Type II Interface Cable Assemblies shall withstand exposure to a pressure/temperature combination of the proof pressure of NAVSEA Drawing 5759651 and +285 degrees F -5/+10 degrees F) without evidence of deformation, leakage, or raised connectorinserts.Copies of the Certificate of Quality Compliance CDRLs shall bedelivered to the Engineering Support Activity, NUWC Newport: NWPT.NUWC_8554_QAPCDRL@navy.mil james.c.ferguson1.civ@us.navy.mil richard.d.penfold2.civ@us.navy.mil patrick.r.faerber.civ@us.navy.mil Recommend a Post Award Conference be conducted with thecontractor/supplier to review the item Key Features. Thegovernment Engineering Support Activity, NUWCNewport,would like to participate in the conference if one is scheduled. ; DATE OF FIRST SUBMISSION=030 DAC ;Certificates of Quality Compliance for the following Cable Assembly requirements shall be delivered to the government via Contract Data Requirements List (CDRL). Electrical Bulk Cable Supplier QA Program Plan. Test data and certificate of test conformance to verify thatthe Bulk Cable components, materials and construction have been testedand that all related requirements have been met (53711-5906555). Notarized Certificate of Compliance for each lot of deliveredMolding Compound material (53711-6105323) certifying that the materialmeets the specified requirements. Preproductionsample inspection and test data. Production Quality Conformance inspection and test data. Periodic Quality Conformance inspection and test data. Copies of the Certificate of Quality Compliance CDRLs shall be deliveredto the Engineering Support Activity, NUWC Newport: NWPT.NUWC_8554_QAPCDRL@navy.mil james.c.ferguson1.civ@us.navy.mil richard.d.penfold2.civ@us.navy.mil patrick.r.faerber.civ@us.navy.mil ; DATE OF FIRST SUBMISSION=ASREQ ;Engineering Support Activity, NUWC Newport: james.c.ferguson1.civ@us.navy.mil richard.d.penfold2.civ@us.navy.mil patrick.r.faerber.civ@us.navy.mil ;
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/52572c23b572401fba4e003db90586c2/view)
 
Record
SN06592787-F 20230217/230215230117 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.