Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF FEBRUARY 08, 2023 SAM #7743
SOLICITATION NOTICE

Z -- 657-21-117JB Correct Deficiencies Identified During Triennial Testing - STL, Construction

Notice Date
2/6/2023 10:42:12 AM
 
Notice Type
Presolicitation
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
255-NETWORK CONTRACT OFFICE 15 (36C255) LEAVENWORTH KS 66048 USA
 
ZIP Code
66048
 
Solicitation Number
36C25523R0066
 
Response Due
3/6/2023 8:00:00 AM
 
Archive Date
05/05/2023
 
Point of Contact
Jennifer Sotomayor, Contract Specialist, Phone: 913-946-1142
 
E-Mail Address
jennifer.sotomayor@va.gov
(jennifer.sotomayor@va.gov)
 
Small Business Set-Aside
VSA Veteran-Owned Small Business Set-Aside (specific to Department of Veterans Affairs)
 
Awardee
null
 
Description
657-21-117JB Correct Deficiencies Identified During Triennial Testing Broad Scope of Work (See Plans and Specifications for the full Scope of Work) The mission of the Veterans Affairs Saint Louis Health Care System (VASTLHCS) is to provide the highest quality health care to our nation s veterans. In order to accomplish this mission, VASTLHCS Facility Engineering Service (FES) intends to partner with an A/E Firm on a project to make corrections to electrical system components at the Jefferson Barracks (JB) Division, St. Louis, MO 63125. The Construction firm must provide construction services as delineated in the Plans and Specifications. The following deficiencies below were identified during the FY2019 Triennial Electrical Testing required under VHA Directive 1028. This project will correct deficiencies remaining after testing. New equipment shall have all the required working clearances. Building 1 Replacement of panels per plans and specifications. Building 3 Replace Panel P3 in Basement Mechanical Room 001. Provide NEMA 3R, and misc per plans and specifications. Building 18 Replace transformer and panel(s) per plans and specifications. Building 24 Replace panels in Ground Floor Kitchen Room G06 per plans and specifications. Building 25 replace panels per plans and specifications. Building 51A Replace switchboard and other issues per plans and specifications. Building 53 - Replace (3) obsolete transfer switches and transformer per plans and specifications. The majority of electrical equipment in this facility has sprinkler heads, related water pipes and drainpipes directly over or within the spray pattern of the electrical equipment as represented by the picture to the right. Install protective covers to prevent water from getting into the electrical equipment nor are physical protective devices installed to protect the actual sprinkler heads from physical damage. Both are required by National Electric Code section 110.26(F)(1)(a) through (F)(1)(d). Shields need to be installed in all areas where electrical components are within the spray pattern or have overhead water lines to prevent damage to prevent overhead water sources (sprinklers and water lines) from penetrating the enclosures. Such penetration could lead to a potentially catastrophic failure. Protective covers or cages need to be installed on unprotected sprinkler heads to prevent accidental activation with the same potential for catastrophic failure as mentioned above per plans and specifications.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/3e47040d7cad4c2ca0939eddefe8ff2f/view)
 
Place of Performance
Address: Jefferson Barracks VAMC 1 Jefferson Barracks Dr, St. Louis 63125
Zip Code: 63125
 
Record
SN06583219-F 20230208/230206230110 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.