SOLICITATION NOTICE
J -- MAFB Bldg. 1918 Fire Systems Repair
- Notice Date
- 1/13/2023 11:53:14 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 561621
— Security Systems Services (except Locksmiths)
- Contracting Office
- FA4626 341 CONS LGC MALMSTROM AFB MT 59402-6863 USA
- ZIP Code
- 59402-6863
- Solicitation Number
- FA4626-23-Q-0006
- Response Due
- 1/17/2023 1:00:00 PM
- Archive Date
- 02/01/2023
- Point of Contact
- Karen V. Broughton, Phone: 4067314555, Rhiannon DeForest, Phone: 4067314009
- E-Mail Address
-
karen.broughton@us.af.mil, rhiannon.deforest.2@us.af.mil
(karen.broughton@us.af.mil, rhiannon.deforest.2@us.af.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- The contractor shall provide a fully functional existing Automatic Fire Detection System, and a fully functional existing Manual Fire Alarm System, utilizing all existing operational government� furnished equipment, and materials and components that are found to not be operational but are� necessary for the completion of the project shall be provided by the contractor. The Contractor� shall inspect, troubleshoot, execute any required maintenance and repairs, necessary to get the� systems back up and running with all faults cleared and finally test and certify the systems as� operational. A government furnished Fire Alarm Control panel, Harrington HS-3200, shall be installed by the� contractor replacing the existing Harrington HS-3400. The contractor shall be qualified on the� instillation and testing of all system components, including a Monaco Transceiver and Harrington� Control Panel HS-3200. Damage to the facility or additional maintenance and repairs required to put� the existing systems back into service, on other than the Fire Systems, shall be the responsibility� of the contractor to repair and make whole. This includes but is not limited to, the existing drop� ceiling and drywall and other interior finishes. All existing and / or removed strobes, pull stations, detectors, circuit wiring, control panel,� transceiver, breakers, and all other components required to make the existing systems function,� shall be reinstalled, repaired, function checked, tested, and certified as operational by the� contractor. (Table 1) below shows what was existing in each of the 17 rooms of the facility that� shall be reinstalled and certified by the contractor as operational, see (Figure 1) for the� corresponding existing floor plan. Additionally, a fire system CAD as-build shall be provided to� the government after project completion and saved as an .dwg. This file shall encompass both the� Automatic Fire Detection System circuit and a Manual Fire Alarm System circuit and the locations of� all components. The existing CAD as-builds may be provided by the government upon request. �
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/8a4d94f993dd417699a518d2e2594e27/view)
- Place of Performance
- Address: Malmstrom AFB, MT 59402, USA
- Zip Code: 59402
- Country: USA
- Zip Code: 59402
- Record
- SN06563941-F 20230115/230113230104 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |