SOLICITATION NOTICE
41 -- South Central Regional Office Install Air Cooled Condensers
- Notice Date
- 9/2/2022 8:16:31 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 333415
— Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- Contracting Office
- SCRO GRAND PRAIRIE TX 75051 USA
- ZIP Code
- 75051
- Solicitation Number
- 15B50022Q00000001
- Response Due
- 9/16/2022 1:00:00 PM
- Archive Date
- 10/01/2022
- Point of Contact
- Kenny Cook, Phone: 9727308896, Donald Osborn, Phone: 972-730-8884
- E-Mail Address
-
kxcook@bop.gov, dosborn@bop.gov
(kxcook@bop.gov, dosborn@bop.gov)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- The Federal Bureau of Prisons (FBOP), South Central Regional Office U.S. Armed Forces Reserve�Complex 344 Marine Forces Drive, Grand Prairie, TX 75051, intends to make a single award to a�responsible entity that will provide all necessary equipment, labor, materials, and incidentals to�install two In-Row CRV Systems for server room located inside the Designation and Sentence� Computation Center (DSCC) Building 345. All equipment specified in this statement must be brand name or an equal product. Should your firm�choose to submit an equal product, you must submit all technical specification of the equal product�to be analyzed and a technical determination issued with acceptance/non-acceptance. B. SCOPE OF WORK Install CRV In-Row 10-Ton System(s) This project basis for design is CRO35RA air-cooled 35kW with DX Cooling Coil(s) and a period of�performance of 182 calendar days. Contractor shall supply and install (2) new Liebert air handlers�in server room located inside DSCC Building 345 including (2) associated Liebert air-cooled�condenser units on rooftop with disconnects. (1) system to be set up as redundant system. Scope of Work Clarification -Rooftop installation shall include required roof rails and roofing patch back ensuring no water�leaks. ***(Ref. Attachment D)*** -Contractor shall provide all required crane and rigging. -New systems will utilize R410A or R407A refrigerant. -Air Handler units to be installed on floor location inside server room with best air flow�determined on-site by contractor. ***Reference Attachment B for current rack location(s).*** - Certified contractor shall install new line sets from condenser to air handlers, install both 24v�control wire and CANbus� � � communication wire between indoor and each outdoor condenser. -Install (2) 480v 3ph 50-amp dedicated circuits to Liebert air handlers. Install (2) 480v 3ph� 15-amp dedicated circuits to Liebert condenser on rooftop with disconnects. (All existing� electrical distribution equipment is currently Square D brand) ***Reference Attachment B for�electric panel locations and estimated feet required for power runs. *** -Install copper 3/8 supply domestic water piping from mechanical room to each air handler for�humidifiers. -Install condensate drain piping from each air handler to a floor drain in the mechanical room. -Pressurize refrigerant line set and check for leaks. -Pull vacuum online set below 500 microns. -Charge system with factory charge. -Factory start up on installed equipment. -Include 1 Year entire parts and labor warranty. �
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/b75aae3ea82c4cd2a8c5e716ae92497a/view)
- Place of Performance
- Address: Grand Prairie, TX 75051, USA
- Zip Code: 75051
- Country: USA
- Zip Code: 75051
- Record
- SN06452164-F 20220904/220902230127 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |