Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF SEPTEMBER 01, 2022 SAM #7580
SOLICITATION NOTICE

66 -- *NEW* 534-22-4-131-0540: Real-Time PCR System (VA-22-00081613)

Notice Date
8/30/2022 2:24:43 PM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
RPO EAST (36C24E) PITTSBURGH PA 15212 USA
 
ZIP Code
15212
 
Solicitation Number
36C24E22Q0274
 
Response Due
9/6/2022 8:59:00 AM
 
Archive Date
11/05/2022
 
Point of Contact
Ms. Millicent Covert, Contracting Officer, Phone: (412) 822-3488
 
E-Mail Address
millicent.covert@va.gov
(millicent.covert@va.gov)
 
Awardee
null
 
Description
Page 6 of 6 This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This is a Request for Quote (RFQ) and the solicitation number is 36C24E22Q0274. The government anticipates awarding a firm-fixed price contract resulting from this combined synopsis/solicitation. This solicitation is issued as Full and Open Competition. It is the responsibility of the contractor to be familiar with the applicable clauses and provisions. The clauses may be accessed in full text at www.acquisition.gov. STATEMENT OF NEED (SON) CONTRACT DESCRIPTION AND REQUIREMENTS Regional Procurement Office - East has a purchase requirement for an Applied Biosystems QuantStudio 5 Real-Time PCR System for the Charleston VA Research Department. A firm-fixed price contract will be awarded for the purchase of brand name equipment in accordance with all terms, conditions, provisions, specifications and schedule of this solicitation herein. Quotes shall contain the Offeror s best terms for cost/price and technical capabilities of the Applied Biosystems equipment. The government reserves the right to award without discussions. 1.1 PRICING The Offeror shall submit price quotes for the required brand name equipment to the specifications listed in Section 1.2 below. Please enclose the established price list and description of capabilities and product specifications for the required equipment. Please identify items as being on GSA schedule and reference the contract number for each item. Note: The Offeror should include a description of any support services or warranty information in the technical quote. 1.2 REQUIRED PRODUCTS & SPECIFICATIONS Applied Biosystems QuantStudio 5 Real-Time PCR System and all accompanying equipment to add to existing units on station for compatibility and continuity of on-going research. ITEM INFORMATION ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT 0001 *BRAND NAME ONLY* QS5 0.2ML QPCR SYSTEM TOWER Applied Biosystems QuantStudio 5 Real-Time PCR System, 96-well, 0.2 mL, desktop, Includes: Desktop computer, Volume Thermal Block Sample: 0.2mL, Block Format: Non-Interchangeable 1.00 EA 0002 *BRAND NAME ONLY* TAQMAN RNASE P 96-WELL INSTR Applied Biosystems TaqMan RNase P Instrument Verification Plate for ViiA 7 System, 96-well (for 0.2 mL block), For Use With: ViiA 7 System 1.00 EA 0003 *BRAND NAME ONLY* OPTICAL ADHESIVE COVERS Applied Biosystems MicroAmp Optical Adhesive Film, No. per Case: 25 Covers, Content And Storage: Includes 25 Optical Adhesive Covers 1.00 EA 0004 *BRAND NAME ONLY* 96-WELL HARD SHELL PLATE CLEAR Applied Biosystems MicroAmp EnduraPlate Optical 96-Well Clear Reaction Plates with Barcode (20 per case) 1.00 EA 0005 *BRAND NAME ONLY* MICROAMP 96-WELL RXN PLATE (10 plates) 1.00 EA 0006 *BRAND NAME ONLY* SMARTSTART QS 3/5 1DAY CS E 1.00 EA 0007 *BRAND NAME ONLY* 96-WELL HARD SHELL PLATE CLEAR Applied Biosystems MicroAmp EnduraPlate Optical 96-Well Clear Reaction Plates with Barcode (20 plates) 1.00 EA 0008 *BRAND NAME ONLY* OPTICAL ADHESIVE COVERS Applied Biosystems MicroAmp Optical Adhesive Film (25 per case) 1.00 EA 0009 *BRAND NAME ONLY* TAQMAN FAST ADVANCED MMIX Applied Biosystems TaqMan Fast Advanced Master Mix, Quantity: 1 x 5 mL, Concentration: 2X, Detection Method: Primer-Probe Detection, Fidelity: 2X, Form: Liquid, Format: GC-Rich PCR Performance: High, No. of Reactions: 500 Reactions, PCR Method: qPCR, Reaction Speed: Fast, Volume: 5 mL 1.00 EA 0010 *BRAND NAME ONLY* POWERUPSYBRGREEN MM 5ML Applied Biosystems PowerUp SYBR Green Master Mix, No. of Reactions: 500 reactions, Quantity: 5mL 1.00 EA 0011 *BRAND NAME ONLY* SUPERSCRIPT VILO Invitrogen SuperScript VILO cDNA Synthesis Kit, Quantity: 50 reactions 1.00 EA 0012 SHIPPING 1.00 JB 1.3 Product Capabilities & Salient Characteristics or equal The Ergul Lab requires the measurement of gene expression of multiple genes of interest (25+) involved in brain injury and repair, from primary cells grown in culture or from small portions of brain and vascular tissue collected from rats, using quantitative (q)PCR. Equipment must allow for measurement of multiple samples accurately, with highly reproducible measurements, using minimal amounts of sample and reagents. The Applied Biosystems QuantStudio 5 Real-Time PCR Detection System allows for 96 samples to be run simultaneously, under precise temperature control, using multiple individual fluorophores, in samples sizes ranging from 1µl-100µl, with a single DNA copy, while maintaining the ability to consistently detect differences between samples as small as 1.5-fold over 10 orders of magnitude. Real-Time PCR System shall have: High-performance system with a wide programmable temperature range from 4°C to 100°C The ability to amplify 1 copy of target DNA (sensitivity for number of copies) with a resolution of 1.5-fold difference in target quantities. 96-well capacity, compatible with all formats (single tubes, 8-tube strips, and 96-well plates) Small footprint of (W x D x H) 27 x 50 x 40 cm to fit in the designated laboratory bench space VeriFlexT block technology (or equivalent) running independent Peltier blocks in 6 independent zones for temperature zone precision and gradient reaction optimization Ability to support both Standard and Fast run modes Ability to use pre-calibrated 4-color White LED optical system (unparalleled in its ability to excite up to 6 different fluorophores) capable of exciting probes in the 450 680 nm range, and detecting fluorescence emission in the 500 730 nm range. Ability to prevent loss of multiplex-capabilities with fast run programs Ability to provide optional passive reference dye for diagnose of non-PCR related discrepancies Simple recalibration procedures to maintain optimal performance Gesture-based touchscreen with simple user interface for easy stand-alone use Ability to interface with a computer (PC/MAC compatible) or network (Ethernet LAN/WiFi-enabled), if needed The Government is not responsible for locating or securing any information not provided in the quotation by the Offeror. To ensure that sufficient information is available, the Offeror must furnish, as a part of the quote, all descriptive material necessary for the purchasing activity to determine whether the products meet the salient characteristics of this requirement. Offers that do not have descriptive material will not be considered for award. Instructions to the Offeror Basis for award resulting from this RFQ will made to the Best Value Offer that provides a complete package pursuant to the preparation requirements set forth in 52.212-1. FAR 52.212-2 (Evaluation - Commercial Items) will be incorporated in full text into the RFQ and will be evaluated on the following factors. Evaluations will be in accordance with FAR 13 Simplified Procedures. Evaluation Factors for Award: Factor 1 - Technical Capabilities All offerors must meet or exceed all requirements and salient features as listed in the Statement of Need. Factor 2 - Past Performance Past Performance will be based on the most current CPRS Report. Factor 3 - Price The following FAR provision and clauses apply to this solicitation and are incorporated by reference. The solicitation document, incorporated provision and clauses are those in effect through the Federal Acquisition Circular (FAC) 2005-89, Effective July 2, 2015. It is the responsibility of the contractor to be familiar with the applicable clauses and provisions. The clauses may be accessed in full text at www.acquistion.gov. This contract incorporates one or more clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. FAR 52.212-1 Instructions to Offerors Commercial FAR 52.212-2 Evaluation- Commercial Items FAR 52.212-3 Offeror Representations and Certifications FAR 52.212-4 Contract Terms and Conditions FAR 52.212-5 Contract Terms and Conditions Required To Implement Statutes Or Executive Orders Commercial Item FAR 52.219-6 Notice of Total Small Business Set-Aside (Nov 2011) FAR 52.219-8 Utilization of Small Business Concerns (Oct 2014) FAR 52.233-3 Protest After Award (Aug 1996) FAR 52.211-6 Brand Name or Equal FAR 52.233-2 Service of Protest Quotes shall be submitted via email to millicent.covert@va.gov and Offerors must reference Solicitation 36C24E22Q0274 in the subject line of the email. No telephone request for information will be considered. Incomplete packages will be considered nonresponsive. All offers must be received by the closing date Tuesday, September 6, 2022, NLT 11:59 AM EST.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/676f30384c5f4a5095012f247f991c8c/view)
 
Place of Performance
Address: Ralph H. Johnson VA Medical Center 109 Bee St, Charleston 29401
Zip Code: 29401
 
Record
SN06446857-F 20220901/220830230129 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers