Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JUNE 24, 2022 SAM #7511
SOLICITATION NOTICE

66 -- NPR060 Refrigerator Temperature Monitoring System

Notice Date
6/22/2022 3:07:16 AM
 
Notice Type
Presolicitation
 
NAICS
334513 — Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
 
Contracting Office
248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
 
ZIP Code
33637
 
Solicitation Number
36C24822Q1035
 
Response Due
6/27/2022 10:30:00 AM
 
Archive Date
07/02/2022
 
Point of Contact
MARCUS LEWIS, CONTRACT SPECIALIST, Phone: 813-940-0316
 
E-Mail Address
MARCUS.LEWIS2@VA.GOV
(MARCUS.LEWIS2@VA.GOV)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
GENERAL: The newly constructed leased consolidation project at New Port Richey Community Based Outpatient Clinic (NPR CBOC) at 7900 Little Road, New Port Richey, FL 34654-3419. The facility is combining and expanding its services. BACKGROUND: The NPR CBOC is expanding services in the new facility and has a requirement to monitor the temperature of newly purchased medical refrigerators/freezers. The procurement of the below listed equipment is required to expand upon the current CheckPoint Monitoring system contract in place with the Tampa VA facility. SCOPE: The refrigerators and freezers that will utilize temperature monitoring will be in the lab, radiology, primary care clinics, multispecialty care clinic, eye clinic, dental clinic, pharmacy, and mental health clinics for routine storage and dispensing of medications completed by the NPR CBOC and local providers. This is a brand name only solicitation due to the current Checkpoint Monitoring system server and contract in place at the facility. This ensures continuity of care enterprise wide, no need to stock consumable supplies that are not currently being used. ESTIMATED QUANTATIES: TEMP121 Qty 24 Sensor with Snap Calibration Probe (-40 to 50 degrees C) TEMP135 Qty 3 Sensor with Thermocouple Probe TEMP124 Qty 8 Sensor with 4 Metal Probe for Insertion in Glycol Bottle TEMP125 Qty 11 Sensor with a temperature and humidity probe TEMP140B Qty 8 20 oz bottle of PGX Iceclear Product Simulation Solution for CheckPoint Temperature Monitoring TEMP105 Qty 2 Ether Base TEMP101 Qty 3 Repeater for Temperature Transmitter SPECIFIC NEED/ SALIENT CHARACTERISTIC S TEMP121 Sensor with Snap Calibration Probe (-40 to 50 degrees C) to include the following: Sensor: Sensor Range:(Internal): -20°F ~ 120°F Sensor Range (Single External): -112°F ~ 300°F with different probes Accuracy: +/- 0.25°C (0.5°F) Other sensor types Humidity 3% Accuracy 20~80% RH 4~20 mA voltage input from other sensing devices (available Q4 2006) Motion Door open/close Differential pressure C02 Liquid Nitrogen Dual probe Memory: 7 days at 15 minute interval Default transmission interval: Every 15 minutes Signal Strength: +7 dBm (5 mW) for 80 to 120 mS Enclosure: Splash-proof, 1.5 x 2.5 x 4 , approx 5 oz. Installation: Mounting clip with tape or screws Battery: 2 x AA Battery Life: Approx 3 years Operating Environment: -20°F ~ 120°F Open field range: 1000 ft Typical range in building: 50 to 200 ft Probe: Snap calibration probe (-40 to 50 degrees C) TEMP135 Sensor with Thermocouple Probe to include the following: Sensor: Sensor Range:(Internal): -20°F ~ 120°F Sensor Range (Single External): -112°F ~ 300°F with different probes Accuracy: +/- 0.25°C (0.5°F) Other sensor types Humidity 3% Accuracy 20~80% RH 4~20 mA voltage input from other sensing devices (available Q4 2006) Motion Door open/close Differential pressure C02 Liquid Nitrogen Dual probe Memory: 7 days at 15 minute interval Default transmission interval: Every 15 minutes Signal Strength: +7 dBm (5 mW) for 80 to 120 mS Enclosure: Splash-proof, 1.5 x 2.5 x 4 , approx 5 oz. Installation: Mounting clip with tape or screws Battery: 2 x AA Battery Life: Approx 3 years Operating Environment: -20°F ~ 120°F Open field range: 1000 ft Typical range in building: 50 to 200 ft Probe: Thermocouple probe TEMP124 Sensor with 4 Metal Probe for Insertion in Glycol Bottle to include the following: Sensor: Sensor Range:(Internal): -20°F ~ 120°F Sensor Range (Single External): -112°F ~ 300°F with different probes Accuracy: +/- 0.25°C (0.5°F) Other sensor types Humidity 3% Accuracy 20~80% RH 4~20 mA voltage input from other sensing devices (available Q4 2006) Motion Door open/close Differential pressure C02 Liquid Nitrogen Dual probe Memory: 7 days at 15 minute interval Default transmission interval: Every 15 minutes Signal Strength: +7 dBm (5 mW) for 80 to 120 mS Enclosure: Splash-proof, 1.5 x 2.5 x 4 , approx 5 oz. Installation: Mounting clip with tape or screws Battery: 2 x AA Battery Life: Approx 3 years Operating Environment: -20°F ~ 120°F Open field range: 1000 ft Typical range in building: 50 to 200 ft Probe: 4 metal probe TEMP125 Sensor with a temperature and humidity probe to include the following: Sensor: Sensor Range:(Internal): -20°F ~ 120°F Sensor Range (Single External): -112°F ~ 300°F with different probes Accuracy: +/- 0.25°C (0.5°F) Other sensor types Humidity 3% Accuracy 20~80% RH 4~20 mA voltage input from other sensing devices (available Q4 2006) Motion Door open/close Differential pressure C02 Liquid Nitrogen Dual probe Memory: 7 days at 15 minute interval Default transmission interval: Every 15 minutes Signal Strength: +7 dBm (5 mW) for 80 to 120 mS Enclosure: Splash-proof, 1.5 x 2.5 x 4 , approx 5 oz. Installation: Mounting clip with tape or screws Battery: 2 x AA Battery Life: Approx 3 years Operating Environment: -20°F ~ 120°F Open field range: 1000 ft Typical range in building: 50 to 200 ft TEMP140B 20 oz bottle of PGX Iceclear Product Simulation Solution for CheckPoint Temperature Monitoring accessory to TEMP124 Sensor with 4 Metal Probe for Insertion in Glycol Bottle TEMP105 Ether Base to include the following: Power requirements: 120 VAC with transformer to 6 VDC Signal Strength: +27 dBm (500 mW) Installation requirements: Wall Mounting clip with screws Enclosure: 6 x 6 x 2 20 oz Open field range: 1 mile Typical range in building: 200 ft to 400 ft TEMP101 Repeater for Temperature Transmitter to include the following: Power requirements: 120 VAC with transformer to 5 VDC Memory: 2 to 7 days, based on sensors in range Signal Strength: +27 dBm (500 mW) Installation: Wall Mounting clip with screws Enclosure: 1.5 x 12.5 x 4 5 oz Open field range: 1 mile Typical range in building: 200 ft to 400 ft
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/7170d444530449d0a468440850a21a3a/view)
 
Place of Performance
Address: New Port Richey Community Based Outpatient Clinic PMR Section 7900 Little Rd,, New Port Richey, FL 34654-3419, USA
Zip Code: 34654-3419
Country: USA
 
Record
SN06365794-F 20220624/220623060617 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.