SOLICITATION NOTICE
45 -- VARO 317 water bottle filling stations BLDG 46-Replacement of the the existing water fountains for water bottle filling stations on BLDG 46 2nd and 3rd floor.
- Notice Date
- 6/13/2022 4:49:13 AM
- Notice Type
- Solicitation
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- VBA FIELD CONTRACTING (36C10E) WASHINGTON DC 20006 USA
- ZIP Code
- 20006
- Solicitation Number
- 36C10E22Q0104
- Response Due
- 6/17/2022 1:00:00 PM
- Archive Date
- 07/17/2022
- Point of Contact
- Jeffrey A Reed, Contract Specialist
- E-Mail Address
-
jeffrey.reed@va.gov
(jeffrey.reed@va.gov)
- Awardee
- null
- Description
- 1) As the specified Elkay model # LZWSM8PK is an inwall model (lzwsm8pk_spec.pdf (elkayfiles.com)), please provide the following: *Confirmation that walls where the units will be installed have the minimum 12 depth *Wall Types for all x10 locations I*f the existing units have a larger footprint than the new unit, please advise how to repair the wall -Please update the equipment criteria of the solicitation to reflect the following: The current water fountain stations are surface mounted and the bottle filling station that will replace must be surface mounted. The bottle filling stations must be comparable to ELKAY MFR PART #EZ8WSSSMC. The ELKAY model number in the SOW is incorrect and must be corrected to show comparable to ELKAY MFR #EZ8WSSSMC. 2) Confirm that there are shutoffs at each of the existing locations Yes, all location are good. 3) As the building has been unoccupied for 2 years, please confirm the assumption is that all existing shutoffs, waste lines and supply lines are in operational condition. Yes, all location are good. 4) Section 52.212 states we need to provide a Technical and past performance. Please elaborate on what is required for these items. Technical submit information showing that your company has the technical ability to complete this contract Past Performance submit information showing previous contracts completed where your company performed similar work on a similar scale. Keep in mind, if you do not have previous experience, this will be considered a neutral mare on your evaluation (neither negative or positive). 5) Due to continuing supply chain issues, it is unclear if the bottle fillers can be sourced and installed within 30 days of award. Please advise. - Contractor awarded must maintain the within 30 days of the award to be installed. Our market research has provided numerous sources that have equipment comparable to #EZ8WSSSMC in stock and ready to ship.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/d3d5052e573a4865b7a895990ecdf57c/view)
- Record
- SN06356233-F 20220615/220613230105 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |