Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 29, 2022 SAM #7485
SOURCES SOUGHT

39 -- Sources Sought � Survival Systems USA, Inc. Model 12000 SmartJib Crane

Notice Date
5/27/2022 5:04:33 PM
 
Notice Type
Sources Sought
 
NAICS
333923 — Overhead Traveling Crane, Hoist, and Monorail System Manufacturing
 
Contracting Office
NAVAL FAC ENGINEEERING CMD PACIFIC JBPHH HI 96860-3134 USA
 
ZIP Code
96860-3134
 
Solicitation Number
N6274222SSU
 
Response Due
6/10/2022 6:00:00 PM
 
Point of Contact
Nam Phan, Phone: 8086007570
 
E-Mail Address
nam.q.phan.civ@us.navy.mil
(nam.q.phan.civ@us.navy.mil)
 
Description
Notice of intent to use a brand name product. The Naval Facilities Engineering Systems Command, Pacific (NAVFAC Pacific) is performing a market survey to determine if other potential sources of supply can provide a jib crane that has equal performance and listing/approval requirements to the Survival Systems USA, Inc. Model 12000 SmartJib Crane. This notice seeks products that have equal performance and listing/approval requirements as the Model 12000 SmartJib Crane, but are not manufactured by Survival Systems USA, Inc.� JFY22 Project J-014, Physical Training Complex, Camp Blaz MCB Guam requires one (1) jib crane that has the following characteristics: CONTROLS AND OPERATION: 1. Programmable and provide redundant variable speed hoist(s) to raise and lower Egress Training Simulators (ETSs) at variable-speed rates of descent and retraction and shall be controllable by the operator. Operating Speed parameters: � Slow raise/lower 3.0m/min (9.8 ft/min) � Fast raise 10m/min (32.8 ft/min) � Available ditching speed 19-30 m/min (62�98.4 ft/min) adjustable through operator interface � Recommended ditching speed 20m/min (65.6 ft/min) 2. Programmable integrated control system that provides primary and redundant remote control of the entire training scenario to include the ETS, lifting device(s) 3. Fully certified by DNV with industry personnel lift guidelines, including EN 13852, API 2C, NAVFAC P-307, and DNV Rules for Certification of Lifting Appliances.� The Model 12000 SmartJib� is a 24000 lbs static lift system de-rated to 12000 lbs dynamic condition safe personnel working load capacity for lifting training devices in all weather conditions. 4. Complete duality in variable frequency drive lifting mechanisms, VFDs (2), motors (2), gear boxes (2), drums (4), and cables (4). Each system is capable of independently holding and handling the load through the SmartJib� leveling block system. 5. The crane must be capable of raising the ETS from a fully submerged status for emergency, at fast speed, from any angle without damaging any equipment, infrastructure, handling system, pool or deck. No single component failure shall result in loss of control of the Aquatics Training Device (ATD) and/or cause an inability of raising the simulator from a submerged position. Crane Safety and risk mitigation - Aquatics Training Device (ATD) The ATD Handling System shall be capable of delivering aquatics training in a realistic, safe, and reliable manner with proven engineered solutions to address each of the following points essential to risk mitigation: 1. The handling system shall minimize the risk of capacity-related failures; and in order to meet international guidelines for personnel lifting and handling, the handling system complete with structure, must be used at 50% of its' rated capacity or less, including emergency raise and submerging cycles. 2. The system shall minimize risk of repetitive cyclical shock and fatigue effects on structure, gear assemblies, drives, and wire ropes. [i.e., use of soft start / stop mechanisms] 3. The system shall minimize the risk of being unable to raise the simulator from a ditched position, including total electrical power failure. Must be designed to provide failsafe redundant safety systems such as an independent pneumatic retraction system. 4. The system shall minimize the discharge of foreign substances or other contaminates into swimming pools which can result in public health hazards and create costly downtime and further water sanitation. [ i.e. exclusive use of food grade lubrication systems and corrosion resistant components where applicable]. Shall be environmentally compliant during both transport and operation and shall not produce substances that are classified by the Environmental Protection Agency (EP A) as pollutants to air, ground, and water. 5. The system shall minimize any risk of electrical shock to persons in an aquatic environment by meeting or exceeding existing earth ground fault personnel protection.[i.e. by the use of state-of-the-art active insulation monitoring, engineer witnessed testing and periodic preventative maintenance]. 6. Additional Safety Features include: Independent motor brakes (2) � Pneumatically Operated Redundant Retract System (1) � Integrated Electrical Ground Fault Personnel Protection (1) � Radio Remotes (2) Pendant Crane Control (1) � User Friendly Operator Interface and On-Screen Guide (1) - Operator Training � Installed at Customer�s Site. Functional Requirements: Provide a jib crane assembly that bears on the structural pool decking and supports the trainer fuselage over the pool. The surrounding facility walls and roof structure are not built to withstand additional stresses of a trainer and shall not be used for trainer support. The jib crane shall be installed (no facility modifications required) and fastened to the jib crane foundation using an anchoring system that is best suitable for the application ( e.g. expansion bolt, epoxy anchor bolt system, or equivalent, embedded SmartJib� foundation anchor bolts, base ring and accompanying hardware). Performance/Operating Requirements: Operating capacity of 12000 lbs. Gross Personnel Lift Rotation mechanism - Powered slewing with programmable travel stops c/w obstacle avoidance parameters. Load travel of 30ft nominal, and adjustable for safety in shallow depth pools. Rotation equal to 300 degrees standard (150 degrees left or right from central training position). Boom reach with operating extension of 14.8ft.� Special Design Data: Specifically designed to operate with the METS� line of products (includes the METS� (Modular Egress Training Simulation), the MAET� (Modular Amphibious Egress Trainer), and the SVET (Submersible Vehicule Emergency Egress Trainer), among others)). Electrical System of the SmartJib� designed to eliminate the potential for inadvertently energizing the simulator during use � Control panel provides the operator a single control point from which they can initiate:� � � � � � � � �a. Normal operations� � � � � � � � �b. Fast Raise for simulator resetting� � � � � � � � �c. Emergency Raise (for emergencies with personnel inside the simulator that require an immediate air space)� � � � � � � � �d. Redundant Retract (for full power loss to the facility � pneumatic system can be engaged to lift the simulator out of the water)� Speeds of the system specifically engineered to ensure that no structural damage to the METS�/MAET/SVET is possible due to it being lifted out of the water � regardless of the angle the simulator happens to be at� Levelling Block� � � � � � � � � a. Allows for any of the situations in 2 (a-d) to occur and for the load to be evenly spread across the cables of the system� Designed for any of the situations in 2 above without the risk of birdcaging the cables � Designed with fail safes (set points � high/low) to ensure no potential for bottoming out the simulator on the pool on which it is installed and to ensure the system levelling block cannot be raised to impact the boom tip� System has ?multiple additional connecting points to ensure no single point of failure (additional strops) and to ensure minimal transverse rotation of the system during use � All air lines integral to the operation of the METS/MAET/SVET � this includes the air lines for the operating brake � and the airlines for the Redundant Retract System (RRS) are installed in such a way to eliminate the potential for a hose snag� Air line integration into the SmartJib control panel allows the operator a dedicated digital readout of the available operating air pressures, motor speeds, and motor status� Operating controls are two style � pendant and walk around remote � allowing full, unobstructed view of the operating area� System utilizes a shackle to shackle connection to eliminate the potential for an open latch situation where any flotation of the METS� might result in the METS� coming off the hoist hook This notification is for market research purposes only to identify if other potential sources of supply can meet the requirements of the Government. This is not a request for proposals, quotes or an invitation for bid. The intent of this notice is to identify other potential sources for this product. To be considered, please submit detailed technical data in order for the Government to conduct a comprehensive evaluation of your product to ensure compatibility with the existing system. In accordance with FAR 15.201(e), a response to this notice is not an offer and cannot be accepted by the Government to form a binding contract. The responder is solely responsible for the information it submits and any associated costs. The Government reserves the right to disregard any submittal that is incomplete or that is vague.� Please do not submit your company brochures. Please submit complete information via email to Mr. Nam Phan via electronic mail at nam.q.phan.civ@us.navy.mil no later than 10 June 2022 at 3:00 p.m. H.S.T. Information received after the due date/time will not be considered. Any information provided to the Government in response to this RFI will become U.S. Government property and will not be returned. All proprietary or classified information will be treated appropriately.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/e3fe61f98926422d8091adaa644fa971/view)
 
Place of Performance
Address: Dededo 96929, GUM
Zip Code: 96929
Country: GUM
 
Record
SN06341573-F 20220529/220527230103 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.