SOLICITATION NOTICE
56 -- Control Tower Roof at Carr Creek Lake, Kentucky
- Notice Date
- 5/17/2022 6:06:43 AM
- Notice Type
- Solicitation
- NAICS
- 238160
— Roofing Contractors
- Contracting Office
- US ARMY ENGINEER DISTRICT LOUISVILL LOUISVILLE KY 40202-2230 USA
- ZIP Code
- 40202-2230
- Solicitation Number
- W912QR22Q0061
- Response Due
- 6/16/2022 7:00:00 AM
- Archive Date
- 07/01/2022
- Point of Contact
- Joel Huberman, Phone: 5023157409
- E-Mail Address
-
Joel.Huberman@usace.army.mil
(Joel.Huberman@usace.army.mil)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- The Contractor will replace Control Tower Roof at Carr Creek Lake in Knott County, Kentucky. The contractor shall furnish all necessary materials, supplies, tools, equipment, and labor to complete installation of a Fully Adhered Ethylene Propylene Diene Monomer (EPDM) minimum 90 mil roofing system onto the existing metal decking roof with insulation board that will provide a watertight roof membrane, approved by the Government Technical Point of Contact (TPOC) for the Carr Creek Lake Control Tower Roof. All contractors submitting EPDM roofing systems for approval consideration shall provide product specification from manufacturer and warranty specifications contained in this scope of work. The contractor shall remove the existing roof system, insulation, roof protrusion boot/seals, any loose gravel, dirt, and debris down to metal decking and properly dispose of the material to a site licensed to receive/recycle construction debris in accordance with Federal, State and Local Regulations. The contractor will completely remove the furnace vent and sleeve and 4 lightening rod boxes. The contractor will repair the holes in the decking with like materials. The contractor will install new insulation at a minimum of 2 inches thick and in accordance with a fully adhered EPDM roof system manufactures recommendations. The contractor will install a fully adhered EPDM minimum 90 mil roof system according to manufacturer�s recommendations. The contractor will seal remaining roof penetrations (2 bypass vents, Septic Tank Vent, Generator Exhaust Vent, Roof Access, and Roof Drain) to obtain a watertight seal in accordance with manufactures recommendations.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/82b99ee0439344eb8ce309f3dadc9169/view)
- Place of Performance
- Address: Sassafras, KY 41759, USA
- Zip Code: 41759
- Country: USA
- Zip Code: 41759
- Record
- SN06329695-F 20220519/220517230105 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |