SOLICITATION NOTICE
H -- Hood Inspections & Maintenance
- Notice Date
- 5/4/2022 9:08:21 AM
- Notice Type
- Solicitation
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- 241-NETWORK CONTRACT OFFICE 01 (36C241) TOGUS ME 04330 USA
- ZIP Code
- 04330
- Solicitation Number
- 36C24122Q0499
- Response Due
- 5/6/2022 2:00:00 PM
- Archive Date
- 06/05/2022
- Point of Contact
- Issa J Shawki, Contract Specialist
- E-Mail Address
-
Issa.Shawki@va.gov
(Issa.Shawki@va.gov)
- Awardee
- null
- Description
- The following has been removed from the Performance Work Statement: 3.3.2 USP 797 TESTING FOR PHARMACY CLEAN ROOMS 3.3.2.1 Primary Engineering Controls (PECs) - All primary engineering controls (PECs) including BSCs, LAFWs, CAIs and CACIs shall be tested to NSF 49 (BSCs), CETA CAG-002-2006 (isolators) specifications and/or manufacturer specifications. 3.3.2.2 HEPA Filter Leak Test - The contractor shall perform a proper HEPA filter leak test of the room air supply HEPA filters. 3.3.2.3 Air Changes per Hour - The contractor shall calculate the total room volume for each buffer and ante room. A sketch of the room with dimensions, exhaust/supply diffuser locations and equipment locations shall be included in the report. The contractor shall calculate air changes per hour (ACPH) for each buffer and ante room and include their findings in the report. In the event that a room does not meet USP 797 requirements for ACPH COR. 3.3.2.4 Pressure Requirements - The contractor shall include in their report differential pressure reading from each buffer/ante room to all surrounding areas. The report shall indicate whether the room is required to be a negative or positive pressure room per USP 797. The contractor shall report all pressures to an accuracy of 0.0001. 3.3.3 Report Requirements - All of the following information should be included in the report for clean room certification. Pass/Fail notifications should be included on a per test basis where applicable. - Room number and/or location - Room type (e.g. oncology prep room) - Date of testing - Date of next required certification - Standards used to test room - Notes - Room sketch (location of supply/exhaust diffusers, equipment, room dimensions) - Total room area and volume - Room humidity and temp - Air changes per hour - Pressure differential 5. Clean Room Test Reports for IV Room, Clean Room, and Ante Room shall include: a. List of equipment used to include manufacturer make, model, serial number, and date calibrated. b. Particle Counts c. Room Air Changes per Hour d. Room pressurization test e. Temperature f. Humidity g. Differential pressure between all rooms Updated Attachment A Base Year Hood /Type Certification Frequency Quantity Unit Unit Cost Amount Biological Safety Cabinets (BSC-A2) USP 797 Semi-Annual 4 PMS Biological Safety Cabinets (BSC-B2) USP 797 Semi-Annual 2 PMS Biological Safety Cabinets (BSC-A1) USP 797 Semi-Annual 4 PMS Chemical Fume Hoods Annual 70 PMS Biological Safety Cabinets (BSC-A2) Annual 50 PMS Laminar Air Flow Workstations (USP 797) Semi-Annual 4 PMS Isolator (USP 797) Semi-Annual 6 PMS Hazardous Clean Rooms (USP 797) Semi-Annual 4 PMS Non-Hazardous Clean Rooms (USP 797) Semi-Annual 4 PMS Ante Rooms (USP 797) Semi-Annual 16 PMS Miscellaneous Ductless Enclosure Annual 40 PMS Miscellaneous Local Exhaust Ventilation Annual 20 PMS Filter Replacement (est) as needed 25 EA Repair (est) as needed 15 EA Option Year 1 Hood /Type Certification Frequency Quantity Unit Unit Cost Amount Biological Safety Cabinets (BSC-A2) USP 797 Semi-Annual 4 PMS Biological Safety Cabinets (BSC-B2) USP 797 Semi-Annual 2 PMS Biological Safety Cabinets (BSC-A1) USP 797 Semi-Annual 4 PMS Chemical Fume Hoods Annual 70 PMS Biological Safety Cabinets (BSC-A2) Annual 50 PMS Laminar Air Flow Workstations (USP 797) Semi-Annual 4 PMS Isolator (USP 797) Semi-Annual 6 PMS Hazardous Clean Rooms (USP 797) Semi-Annual 4 PMS Non-Hazardous Clean Rooms (USP 797) Semi-Annual 4 PMS Ante Rooms (USP 797) Semi-Annual 16 PMS Miscellaneous Ductless Enclosure Annual 40 PMS Miscellaneous Local Exhaust Ventilation Annual 20 PMS Filter Replacement (est) as needed 25 EA Repair (est) as needed 15 EA Option Year 2 Hood /Type Certification Frequency Quantity Unit Unit Cost Amount Biological Safety Cabinets (BSC-A2) USP 797 Semi-Annual 4 PMS Biological Safety Cabinets (BSC-B2) USP 797 Semi-Annual 2 PMS Biological Safety Cabinets (BSC-A1) USP 797 Semi-Annual 4 PMS Chemical Fume Hoods Annual 70 PMS Biological Safety Cabinets (BSC-A2) Annual 50 PMS Laminar Air Flow Workstations (USP 797) Semi-Annual 4 PMS Isolator (USP 797) Semi-Annual 6 PMS Hazardous Clean Rooms (USP 797) Semi-Annual 4 PMS Non-Hazardous Clean Rooms (USP 797) Semi-Annual 4 PMS Ante Rooms (USP 797) Semi-Annual 16 PMS Miscellaneous Ductless Enclosure Annual 40 PMS Miscellaneous Local Exhaust Ventilation Annual 20 PMS Filter Replacement (est) as needed 25 EA Repair (est) as needed 15 EA Option Year 3 Hood /Type Certification Frequency Quantity Unit Unit Cost Amount Biological Safety Cabinets (BSC-A2) USP 797 Semi-Annual 4 PMS Biological Safety Cabinets (BSC-B2) USP 797 Semi-Annual 2 PMS Biological Safety Cabinets (BSC-A1) USP 797 Semi-Annual 4 PMS Chemical Fume Hoods Annual 70 PMS Biological Safety Cabinets (BSC-A2) Annual 50 PMS Laminar Air Flow Workstations (USP 797) Semi-Annual 4 PMS Isolator (USP 797) Semi-Annual 6 PMS Hazardous Clean Rooms (USP 797) Semi-Annual 4 PMS Non-Hazardous Clean Rooms (USP 797) Semi-Annual 4 PMS Ante Rooms (USP 797) Semi-Annual 16 PMS Miscellaneous Ductless Enclosure Annual 40 PMS Miscellaneous Local Exhaust Ventilation Annual 20 PMS Filter Replacement (est) as needed 25 EA Repair (est) as needed 15 EA Option Year Hood /Type Certification Frequency Quantity Unit Unit Cost Amount Biological Safety Cabinets (BSC-A2) USP 797 Semi-Annual 4 PMS Biological Safety Cabinets (BSC-B2) USP 797 Semi-Annual 2 PMS Biological Safety Cabinets (BSC-A1) USP 797 Semi-Annual 4 PMS Chemical Fume Hoods Annual 70 PMS Biological Safety Cabinets (BSC-A2) Annual 50 PMS Laminar Air Flow Workstations (USP 797) Semi-Annual 4 PMS Isolator (USP 797) Semi-Annual 6 PMS Hazardous Clean Rooms (USP 797) Semi-Annual 4 PMS Non-Hazardous Clean Rooms (USP 797) Semi-Annual 4 PMS Ante Rooms (USP 797) Semi-Annual 16 PMS Miscellaneous Ductless Enclosure Annual 40 PMS Miscellaneous Local Exhaust Ventilation Annual 20 PMS Filter Replacement (est) as needed 25 EA Repair (est) as needed 15 EA
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/4db238031b384d179ef483b98e35ddcf/view)
- Record
- SN06316812-F 20220506/220504230108 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |