Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MARCH 04, 2022 SAM #7399
SOLICITATION NOTICE

P -- EAR069 Demolition Dormitory Buildings 751 and 753, Eareckson Air Station, Shemya Alaska

Notice Date
3/2/2022 1:05:23 PM
 
Notice Type
Solicitation
 
NAICS
238910 — Site Preparation Contractors
 
Contracting Office
W2SN ENDIST ALASKA ANCHORAGE AK 99506-0898 USA
 
ZIP Code
99506-0898
 
Solicitation Number
W911KB22B0005
 
Response Due
4/5/2022 4:00:00 PM
 
Archive Date
04/19/2022
 
Point of Contact
Ron Perry, Phone: 9077532549
 
E-Mail Address
ronald.perry@usace.army.mil
(ronald.perry@usace.army.mil)
 
Small Business Set-Aside
8A 8(a) Set-Aside (FAR 19.8)
 
Awardee
null
 
Description
EAR069 Demolition Dormitory Buildings 751 and 753, Eareckson Air Station, Shemya AlaskaThis project requires the demolition and abatement of approximately 13,867 SF for B751 and 43,450 SF for B753 and adjacent structures, including the following: all contents inside buildings, abatement and remediation as required, removal and disposal of all salvageable and non-salvageable materials in and outside, site cleanup and restoration. The contractor shall provide all material, equipment, labor, housing, food and transportation required to accomplish the requirements of the scope of work. Comprehensive HAZMAT surveys were completed for both buildings and the types of HAZMAT are: lead based paint, fluorescent light bulbs and ballasts, refrigerators, water coolers, smoke detectors, exit signs, fire suppression cylinders, and asbestos in B751 on 2 kitchen sink coatings. B753 has approximately 1,500 cubic yards of concrete in the foundation and exterior walls plus approximately 2,000 cubic yards of other debris. B751 has approximately 700 cubic yards of concrete in the building plus approximately 1,100 cubic yards of other debris.?The buildings have been abandoned for years and have water damage, mold and moss is also present in them. Both buildings were built in 1991 and are assumed to have approximately 6? concrete pads with 5? thick concrete floors and 6? thick pre-case concrete walls with steel structural support. Sewer manhole 560 is located at edge of B753 foundation - care shall be taken to not damage manhole, or a new manhole shall be installed if damaged. *Visit 'https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?solNo=W911KB22B0005' to obtain more details.*
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/6c6bf3b4d59d463d854d25ef17331000/view)
 
Record
SN06254818-F 20220304/220303211708 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers