SOURCES SOUGHT

H -- NEW-Hydronic Heating Condensing Boilers Inspection- Roseburg VAHC

Notice Date
2/15/2022 10:17:35 AM
 
Notice Type
Sources Sought
 
NAICS
541350 — Building Inspection Services
 
Contracting Office
260-NETWORK CONTRACT OFFICE 20 (36C260) VANCOUVER WA 98662 USA
 
ZIP Code
98662
 
Solicitation Number
36C26022Q0258
 
Response Due
3/1/2022 9:00:00 AM
 
Archive Date
04/30/2022
 
Point of Contact
Jeffrey Hansen, Contract Specialist, Phone: 253-888-4934
 
E-Mail Address
jeffrey.hansen2@va.gov
(jeffrey.hansen2@va.gov)
 
Awardee
null
 
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services: Eight (8) Boiler Inspections in support of the Roseburg, OR VAMC. Perform annual maintenance and inspections, on two hydronic heating condensing boilers. This is a multi-cell chambered type boiler. Purchase one, two-year annual kits for use for opening both boilers on the fire side. Open inspect & clean the first stage chamber only to determine condition of remaining cells. Clean the first stage burner. Open, inspect & flush the water side clean condensate trap, float and lines. Clean drain line, Neutralizer canister and replace neutralizer Rock Media. Cycle limits, safeties, and operating controls. Check combustion Analysis & Return to factory specifications. Perform annual maintenance and inspections on two hydronic heating condensing boilers. This is a multi-cell chambered type boiler. Purchase one, two-year annual kits to use for opening up both the boilers on the fire side. Open, inspect and clean first stage chamber only to determine condition of remaining cells. Clean first stage burner. Open inspect & flush water side, clean condensate trap, float, and lines. Clean drain line, neutralizer canister and replace neutralizer rock media. Cycle limits, safeties, and operating controls. Check combustion analysis and return to factory specifications. Perform annual maintenance and inspections on two hydronic heating condensing boilers. Open & inspect and clean fire side burner, Open & inspect and flush water side. Clean condensate trap, float and lines. Clean neutralizer canister and replace neutralizer rock media cycle limits, safeties, operating controls, check combustion analysis and return to factory specifications. Perform annual maintenance and inspections on two copper fin tube boilers. Inspect the interior of the boilers, clean & vacuum if necessary. Check for leaks in the water, gas flue and condensate lines. Examine venting system for any obstructions. Check the system water pressure/system piping and expansion tank. Check the fill water meter, test boiler water, check control settings and ignitor. Check wiring & connections. Check the flue gas passageways. Inspect the flame. Inspect & clean the burner. Check the manifold gas pressure. Perform start-up checklist. Replace combustion air filters. Check the relief valve, test low water cutoff operates the relief valve every six months. Perform combustion analysis. Potential candidates having the capabilities necessary to provide the above stated services are invited to respond to this Sources Sought Notice via e-mail to Jeffrey Hansen at jeffrey.hansen2@va.gov no later than March 1st NLT 9AM PST. No telephone inquiries will be accepted. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: company name, address, and business size; point of contact name, phone number, and e-mail address; capability statement and if the services are available on a current GSA Federal Supply Schedule contract. NAICS Code 541350 is applicable to determine business size standard. Any questions or concerns may also be directed to Jeffrey Hansen via e-mail. Disclaimer and Important Notes: This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies. Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time.
 
Web Link
SAM.gov Permalink
(https://sam.gov/opp/8d0a1bc96c084112bb27b780c13aff9e/view)
 
Place of Performance
Address: 913 NW Garden Valley Blvd, Roseburg 97471
Zip Code: 97471
 
Record
SN06243663-F 20220217/220215230117 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.