SOURCES SOUGHT
66 -- Metabolic Cart with Monitor & ancillary items for Bronx VAMC
- Notice Date
- 1/27/2022 8:55:05 AM
- Notice Type
- Sources Sought
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- 242-NETWORK CONTRACT OFFICE 02 (36C242) ALBANY NY 12208 USA
- ZIP Code
- 12208
- Solicitation Number
- 36C24222Q0360
- Response Due
- 2/1/2022 10:00:00 AM
- Archive Date
- 02/11/2022
- Point of Contact
- Jonatan Rondon, Contracting Specialist, Phone: 212-686-7500 Ex. 6490
- E-Mail Address
-
jonatan.rondon@va.gov
(jonatan.rondon@va.gov)
- Awardee
- null
- Description
- TITLE: 38-Sources Sought Notice SOL: 36C24222Q0360 DUE: 02/1/2022 at 13:00 EST NAICS: 334516 AGENCY: Department of Veterans Affairs, James J. Peters, VA Medical Center, 130 West Kingsbridge Road, Bronx, NY 10468 POC: Jonatan Rondon Email all responses only to: Jonatan.rondon@va.gov DESCRIPTION: This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential qualifications of all businesses relative to the North American Industry Classification Code (NAICS) 334516. The Department of Veteran s Affairs is seeking all qualified business manufacturer or distributors of small business manufacturers, of functionally equivalent equipment to all the following specifications: Requirement: The Bronx VAMC is seeking brand name or functionally equivalent equipment to the following Cosmed products, to measure indirect calorimetry on our acute care floors, outpatient clinics, and Community Living Center (CLC). 1 ea. Product code # CO9092-12-99 Q-NRG+ metabolic monitor 1 ea. Product code # A-258-900-002 QNRG/NRG+ cart with cylinder holder without clamp 1 ea. Product code # C04756-01-10 QNRG/NRG+ clamp for pole/rail with VESA mounting plate 1 ea. Product code # 00600-02-11 Calibration syringe 3 L for resting/low flows 1 ea. Product code # A870-155-001 Regulator MET Mix (w/ ISO5359 hose assembly) 1 ea. Product code # C03179-01-11 Canopy hood kit, large 5 boxes Product code #A66225003 Flow-REE disposable flow sensor 1 box Product code # A820173002 Q-NRG+ adapter, FiO2 to ventilator 1 box Product code # A182300006 Vent HME anti-bacterial filter 1 box Product code # A182300007 Vent anti-bacterial filter 1 box Product code # A-182-300-004 Anti-Bacterial Filter 1 box Product code # C04690-01-10 Veils Disposable for large canopy hood 1 ea. Annual Repair/Preventative Maintenance Highlighted features of the QNRG+ Metabolic Cart are as follows: Uses single-test kits with disposables for better infection control Small footprint: 4.65 kg (10.3lb), dimensions 31 x 21 x 27cm (12.2x8.3x10.6in) Time saving: Only requires monthly syringe calibration Tests can be performed within 10-15 minutes or less (including warm-up time) Requires only a 5-minute warm-up to start and 0-minute warm-up when used between patients System can be powered by AC battery (with 3 hours autonomy) or by Li-ion battery or if there is loss of electrical power For mechanically ventilated patients: Validated and accurate readings of resting energy expenditure (REE) within +/- 5% or 36 kcal/day REE can calculate 0-7200 kcal/day Ability to be used on spontaneously breathing and mechanically ventilated patients Uses mixing chamber technology Can be used on patients with fraction of inhaled oxygen (FiO2) range of up to 70% (most of our patients require FiO2 >60%) Measures VO2 10-1000 mL/min ±3% or 5mL/min Measures VCO2 10-1000 mL/min ±3% or 5mL/min Measures respiratory quotient 0-2.00 ±5% or 0.04 For spontaneously breathing patients using canopy/hood: Validated and accurate readings of REE within <2% THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement. The applicable North American Classification System (NAICS) Code for this requirement is 334516 (Analytical Laboratory Instrument Manufacturing). Response Email should contain the following information: Name of firm, Socio-Economic category of the firm, complete address, phone & fax number of contacts.
- Web Link
-
SAM.gov Permalink
(https://sam.gov/opp/a9343e6201f24e559114a55a7f3e3b39/view)
- Place of Performance
- Address: Department of Veterans Affairs James J. Peters VA Medical Center 130 West Kingsbridge Road, Bronx, NY 10468, USA
- Zip Code: 10468
- Country: USA
- Zip Code: 10468
- Record
- SN06226933-F 20220129/220127230116 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |