SOLICITATION NOTICE
66 -- Acquisition of a JPK NanoWizard� 4 XP Nano Science Atomic Force Microscope (AFM) System
- Notice Date
- 8/10/2021 10:59:47 AM
- Notice Type
- Presolicitation
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- NATIONAL INSTITUTES OF HEALTH NICHD BETHESDA MD 20817 USA
- ZIP Code
- 20817
- Solicitation Number
- NICHD-21-138
- Response Due
- 8/16/2021 6:00:00 AM
- Archive Date
- 08/31/2021
- Point of Contact
- Amber Harris, Fax: 3014803278
- E-Mail Address
-
amber.harris@nih.gov
(amber.harris@nih.gov)
- Description
- �� � �� �COMBINED SYNOPSIS / SOLICITATION WORKFORM (1)�� �Action Code: �Combined Synopsis/Solicitation (2)�� �Date: 8/10/2021 (3)�� �Year: 2021 (4)�� �Contracting Office Zip Code: 20892 (5)�� �Project Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES (6)�� �Contracting Office Address: 6710B Rockledge Drive Bethesda, MD 20892 (7)�� �Subject/Title: Acquisition of a JPK NanoWizard� 4 XP Nano Science Atomic Force Microscope (AFM) System (8)�� �Proposed Solicitation Number: NICHD-21-138 (9)�� �Closing Response Date: 8/16/2021 (10)�� �Contact Point: Amber Harris (11)�� �Contract Award and Solicitation Number: TBD (12)�� �Contract Award Dollar Amount: TBD (13)�� �Contract Line Item Number(s): TBD (14)�� �Contractor Award Date: TBD (15)�� �Contractor Name: TBD (16)�� �Description: (Background) (i)�� ��This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6 as supplemented with additional information included in this notice. �This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.�� (ii)�� �The solicitation number is NICHD-21-138 and the solicitation is issued as a request for quote (RFQ). (iii)�� �The solicitation document, the incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2021-06 Effective July 12, 2021. (iv)�� �The associated NAICS code is 334516, Analytical Laboratory Instrument Manufacturing, and the small business size standard is 1,000. �The acquisition is being conducted in accordance with the procedures of FAR Part 12 and FAR Part 13.� (v)�� �The Contractor Requirements are listed below: 1.0�� �PURCHASE ORDER TITLE Acquisition of a JPK NanoWizard� 4 XP Nano Science Atomic Force Microscope (AFM) System) �� ��� � 2.0�� �BACKGROUND The mission of the National Institutes of Health (NIH) is to seek fundamental knowledge about the nature and behavior of living systems and to apply that knowledge to enhance health, lengthen life, and reduce illness and disability. � As part of the NIH, the National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) Intramural Research Program (IRP) conducts biomedical research and training related to diabetes mellitus; endocrine, bone, and metabolic diseases; digestive diseases, including liver diseases and nutritional disorders; and kidney, urologic, and hematologic diseases. Intramural research is conducted in the Institute's laboratories and clinical facilities in Bethesda, Maryland and in Phoenix, Arizona. � Miroshnikova lab and the Section on Nuclear Mechanotransduction and Cell Fate Dynamics is part of Laboratory of Molecular Biology (LMB), which is one of NIDDK IRP 17 Laboratories and Branches. �Miroshnikova lab�s work requires, on an ongoing basis, advanced mechanical characterization methods to qualitatively complement other assays, as well as quantitate the major experimental conditions of the section in living cells and organisms. JPK�s atomic force microscope is leading, high-resolution system combing atomic resolution and fast scanning with rates of up to 150 lines/sec and a large scan range of 100�m in one system allowing cell-cell force quantification in addition to mechanical properties of cells, organelles and tissues. It is designed to provide highest mechanical and thermal stability on inverted optical microscopes during long term experiments on samples ranging from single molecules to living cells and tissues. Thus, it is ideal for live cell and tissue/organism imaging and quantitation, which is at the core of Miroshnikova lab operations. 3.0�� �OBJECTIVE The objective of this requirement is to purchase a new live-sample microscope system with DirectOverlay� 2 software compatibility for perfect integration and data correlation with advanced fluorescence microscopy platforms; meaning that the system must allow calibration of optical images and precisely overlay both the optical and the AFM images. This system must conduct mechanical characterization and cell-cell adhesion measurements due to 100micron z scan size, as well as side visualization of the sample. 4.0 �� �SALIENT / REQUIRED FEATURES AND SPECIFICATIONS The new equipment must include the below features necessary to satisfy day to day Miroshnikova lab operations. Atomic Force Microscope (AFM) System AFM Head� ��� �Multi-purpose stand-alone tip-scanning design� ��� �Closed-loop atomic lattice resolution (mica in buffered solution) on inverted microscope under suitable environmental conditions� ��� �Drift minimized concentric design� ��� �Available sample size �140mm x18mm; unlimited for large samples due to tip-scanning design� ��� �Head completely sealed against vapor and liquids� ��� �High Resolution Mode (HRM) delivers atomic resolution (mica lattice in air or buffered solution) on inverted microscope under suitable environmental conditions (active vibration isolation and acoustic enclosure)� ��� �Lowest cantilever deflection noise of any commercial AFM (20mm x 20 mm� ��� �Step size (Resolution): ?1 ?m� ��� �Repeatability (unidirectional): ?2 ?m� ��� �Maximum velocity: 1mm/s� ��� �Compatible with all JPK sample carriers e.g., for glass slides, Petri dishes, coverslips, metal discs, etc.� ��� �Please specify the microscope model when ordering� Fluid Cells and Temperature Control ��� �Insert for Life Science stage� ��� �Temperature range: Room temperature up to 60�� ��� �Compatible with 35x10mm Petri dishes from WPI and TPP (plastic or plastic with glass bottom)� ��� �Adaptors for other suppliers such as Matek, Willco, IWAKI, Ibidi, and BC upon request� ��� �Ports for perfusion tubes and gas supply (only available for certain types of Petri dishes)� ��� �Silicone anti-evaporation seal� ��� �Software control� ��� �Temperature stability 0.1 K� ��� �Please specify the inverted microscope model when ordering� Systems and Configurations for all systems� JPK TopView Optical module to view tip and sample ��� �Integrated camera with images captured directly into the AFM software� ��� �Can be mounted on the AFM head while the head is mounted on the inverted fluorescence microscope as well as standalone� ��� �Top down view perpendicular to sample plane� ��� �Magnification 10x� ��� �Up to 5MP, frame rate max 9 FPS� ��� �Camera connection type USB 2.0� ��� �Please specify the Head (H-XX-XX) JPK SideView� cantilever holder - Side View ��� �Super cut, fixed spring, length: 15.5 mm� ��� �Cantilever holder with precise mounted mirror� ��� �Allows both view from below and front of cantilever� ��� �Visual observation of tip-sample region e.g. for cell pick-up� ��� �Compatible with aqueous solutions and epi-illumination� ��� �Available numerical aperture: 0.3 *Objectives with minimum 4mm working distance required (20x recommended). Sideview and Hybrid stage Nikon are compatible.� Microscopy Kits� JPK Optical System Data Communication Kit ��� �Ubuntu file transfer between JPK SPM and another optical image system for data transfer for DirectOverlay�� ��� �With hardware (network switch, network cables and TTL-cable with BNCconnection)� c-mount 1.0x camera adapter SlimFocus objective lens z-Scanner ��� �SlimFocus z tracking with position sensor for microscope objectives� ��� �Digital controller� ��� �1.5m cable� ��� �Objective lens adapter� ��� �SlimFocus z tracking software� ��� �Range (open loop/closed loop): 180?m/150?m� ��� �Resolution (open loop/closed loop): 1.5nm� ��� �2 BNC cable 2 m length� Vibration and Acoustic Isolation Benchtop Active Vibration Isolation System� ��� �Approved for use with JPK NanoWizard� AFM� ��� �Active bandwidth 0.6 Hz � 200 Hz� ��� �Isolation: 40 dB above10 Hz� ��� �Dimensions: 400 x 500 x 85 mm�� ��� �Weight: 20kg� ��� �External power supply �� � Independently, and not as an agent of the Government, the contractor shall provide equipment and delivery services for Miroshnikova Lab Specifically, the NIDDK requires completion of the following tasks: Task Area 1 � Delivery shall be within 3 months from when Purchase Order was sent to the vendor. Task Area 2 � Shipping will be provided by the vendor to Building 5, Rm 316I, 9000 Rockville Pike, Maryland 20892, which is Miroshnikova�s lab microscopy space.� Task Area 3 � Installation will be provided by factory-trained service engineers of the manufacturer, no later than 2 weeks after delivery, unless postponed by request of the government. Task Area 4 � Warranty will be provided by the manufacturer and serviced by their local service engineer(s) will be no less than 1 year from completion of installation, covering all deliverables, labor, labor and travel, minus consumables. Task Area 5 � Training will be provided within 1 week after installation by applications specialist(s) from the manufacturer.. 5.0�� �PURCHASE ORDER TYPE This Purchase Order is to be a firm fixed price.� 6.0�� �INSPECTION AND ACCEPTANCE Inspection and acceptance will be performed at the place of installation - National Institutes of Health, NIDDK, 9000 Rockville Pike, Maryland 20892. (i)�� �This is a competitive requirement being pursued through the authority granted in FAR 52.211-6, Brand Name or Equal. This is a requirement for a BRUKER NANO, INC. JPK NanoWizard� 4 XP Nano Science Atomic Force Microscope (AFM) System. � (ii)�� �Period of Performance: �Date of Award through the Date/Time of Inspection and Acceptance of the delivered and installed equipment. (viii)�� �The provision at FAR clause 52.212-1, Instructions to Offerors � Commercial Items, applies to this acquisition. (iii)�� �The provision at FAR clause 52.212-2, Evaluation � Commercial Items, is applicable. �Award will be made to the contractor providing the most advantageous quote to the Government. �Technical factors and price considered with technical factors outweighing price. � Specifically, the following technical factors will be evaluated: i.�� �The vendor will be evaluated on their quoted product meeting the specifications under section 16.v 4.0 SALIENT / REQUIRED FEATURES AND SPECIFICATIONS (x)�� �FAR clause 52.212-3, Offeror Representations and Certifications � Commercial Items, is applicable. �An offeror shall complete only paragraphs (b) of this provision if the offeror has completed the annual representations and certificates electronically via http://www.acquisition.gov If an offeror has not completed the annual representations and certifications electronically at the System for Award Management (SAM) website, the offeror shall complete only paragraphs (c) through (p) of this provision. � (xi)�� �FAR clause at 52.212-4, Contract Terms and Conditions � Commercial Items, applies to this acquisition. (xii)�� �FAR clause at 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders � Commercial Items, applies to this acquisition. �Including the following clauses and Prohibitions: i.�� �52.204-25 - Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment. (AUG 2020). ii.�� �52.209-9, Updates of Publicly Available Information Regarding Responsibility Matters (Jul 2013) (41 U.S.C. 2313) iii.�� �52.219-8, Utilization of Small Business Concerns (Oct 2014) (15 U.S.C. 637(d)(2) and (3)) iv.�� �52.219-28, Post Award Small Business Program Representation v.�� �52.222-19, Child Labor�Cooperation with Authorities and Remedies (Jan 2014) (E.O. 13126). vi.�� �52.222-21, Prohibition of Segregated Facilities vii.�� �52.222-26, Equal Opportunity viii.�� �52.222-35, Equal Opportunity for Veterans (Jul 2014) (38 U.S.C. 4212) ix.�� �52.222-36, Equal Opportunity for Workers with Disabilities x.�� �52.222-37, Employment Reports on Veterans (Jul 2014) (38 U.S.C. 4212) xi.�� �52.222-40, Notification of Employee Rights Under the National Labor Relations Act (Dec 2010) (E.O. 13496) xii.�� �52.222-50 Combating Trafficking in Persons xiii.�� �52.223-18, Encouraging Contractor Policies to Ban Text Messaging while Driving� xiv.�� �52.225-1, Buy American--Supplies (May 2014) (41 U.S.C. chapter 83) xv.�� �52.225-13, Restrictions on Certain Foreign Purchases Additional Clauses: i.�� �52.232-33, Payment by Electronic Funds Transfer� System for Award Management (Jul 2013) (31 U.S.C. 3332) ii.�� �FAR 52.211-6, Brand Name or Equal (xiii)�� �Additional Contract Requirements: None (xiv)�� �The Defense Priorities and Allocations System (DPAS) and assigned rating are not applicable.� (xv)�� �Offers shall be submitted via email to amber.harris@nih.gov (17)�� �Place of Contract Performance:� National Institute of Health, NIDDK 5 Memorial Drive Bethesda, MD 20892 (18)�� �Set-aside Status: This is not applicable to this requirement. �
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/f9028902d562485594660ca2dee74ca5/view)
- Place of Performance
- Address: Bethesda, MD 20892, USA
- Zip Code: 20892
- Country: USA
- Zip Code: 20892
- Record
- SN06092294-F 20210812/210811201713 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)