Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF MAY 29, 2021 SAM #7119
AWARD

Z -- Buidling 922 Comm at Kirtland AFB

Notice Date
5/27/2021 3:21:43 PM
 
Notice Type
Award Notice
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
W075 ENDIST ALBUQUERQUE ALBUQUERQUE NM 87109-3435 USA
 
ZIP Code
87109-3435
 
Solicitation Number
W912PP21Q0033
 
Archive Date
06/11/2021
 
Point of Contact
Glenda D. Kohlieber, Phone: 5756524135
 
E-Mail Address
glenda.d.kohlieber@usace.army.mil
(glenda.d.kohlieber@usace.army.mil)
 
Small Business Set-Aside
8AN 8(a) Sole Source (FAR 19.8)
 
Award Number
W912PP21P0014
 
Award Date
05/27/2021
 
Awardee
Four Winds Mechanical HTC/AC Inc. Albuquerque
 
Award Amount
249964.43
 
Description
This action was awarded as an 8(a) Sole Source Set-Aside under the authority of section 8(a) of the Small Business Act.. The contractor shall furnish all parts, material, labor, equipment and supervision necessary to complete the work for Building 922 - COMM.� The work shall include the following requirements listed in the specific requirements.����� � 2. SPECIFIC REQUIREMENTS: � Demolition Contractor shall cut open the road for boring as indicated on drawings. Contractor shall protect and leave in place existing data rack, patch panels, horizontal wire managers, and data cables as indicated on drawings. � Construction Inside Building � 2nd floor Trace wires in each room and re-label face plates to correctly identify them in the patch panel. No additional drops on second floor. No change in face plates ports other than adding correct labels. 1st Floor Student Computer Access Rooms � Add one plate in most convenient spot with two new LMS drops. (12 rooms, 2 LMS drops per room, 24 LMS drops total) Lounge � There are currently two NIPR connections in this room. The plans call for two NIPR and one LMS. Will add one additional plate with one LMS drop. (1 room, 1 LMS drop total) Doorways (2) � Add one NIPR port by each door for access control system. (2 rooms, 1 NIPR drop per room, 2 NIPR drops total) HPLC � Add one phone line on convenient wall (1 room, 1 phone drop total) Val/Pubs � Needs one phone, one LMS/NIPR combination plate, and one NIPR port for printers. There are no ports in this room; will add four additional drops on a single plate in most convenient spot. (1 face plate with four ports � 1 phone, 1 LMS, 2 NIPR) TJ/Wayne Office � Needs two LMS/NIPR combination ports and 1 NIPR port for printer. There are two NIPR connections existing. Will add three additional drops on a single plate in most convenient spot. (1 face plate with three ports � 2 LMS and 1 NIPR) Trace existing wires in each room and re-label face plates to correctly identify them in the patch panel. Face plates and ports on existing NIPR lines and phone lines will not be changed, only re-labeled. Add additional, lockable data rack to separate and terminate NIPR and LMS cables into individual cabinets. Contractor shall provide and install 4 each 66 type block/bracket for new 100pr copper. Contractor will need to terminate directly into 66 type blocks all cat5 and phone cables. Contractor shall be responsible for testing of end devices to assure the fiber is in working order and all receptacles are in working order. Install VRF inside server room of building 922. No building access control system. No equipment to be left on site for lodging. Contractor shall provide new 9.5 in stainless steel vault closure with fire retardant end plates in building 1004 for 100 pair copper The Block at building 922 for the new 100 Pair cable will need to be a grounded, fuse protected BET. Contractor will provide the NIPR Switch. C4 Team will configure and install. NIPR switch model: C9300-48P-1A TAA Contractor will provide and install the LMS Switch. LMS switch model: C9300L-48T-4G-E� Contractor will provide (2) 3 meter and (1) 10 meter fiber jumper cable will be provided. Contractor will provide patch cables � White for phone and gray for NIPR �������� c.� Construction Outside of Building Contractor shall provide and install new 100pr copper in existing conduit as indicate on drawings. Contractor shall also install two new copper protectors at both ends of the conduit run.� Building 922 � user would prefer a BET with 66 type blocks in the comm room. Building 1004 � user will require central Office type wire wrap termination block. Contractor shall provide and install new 4� HDPE as indicated on drawings along with new pull rope. Contractor shall provide and install new 4� HDPE and pull 12 count single mode fiber optic cable Contractor shall provide and install new FDP panels on each end of the cable as indicated on drawings.� New pull rope will also need to be installed.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/97fe0c1daaf9478ebb550477b2a3588d/view)
 
Place of Performance
Address: Kirtland AFB, NM 87117, USA
Zip Code: 87117
Country: USA
 
Record
SN06014398-F 20210529/210527230105 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.