SOURCES SOUGHT
65 -- TRIAGE CHAIRS
- Notice Date
- 5/6/2021 12:28:01 PM
- Notice Type
- Sources Sought
- NAICS
- 339114
— Dental Equipment and Supplies Manufacturing
- Contracting Office
- 250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
- ZIP Code
- 45428
- Solicitation Number
- 36C25021Q0665
- Response Due
- 5/10/2021 7:00:00 AM
- Archive Date
- 05/25/2021
- Point of Contact
- Percy E Johnson, Phone: 6142575534
- E-Mail Address
-
percy.johnson2@va.gov
(percy.johnson2@va.gov)
- Description
- Please note that this is not a request for quotes or proposals. The government is seeking information for market research purposes only. The Detroit VA Medical Center is currently conducting a market survey for qualified vendors capable of providing A-Dec Dental Chairs. The North American Industry Classification System (NAICS) code is 339114. Responses to this notice must be submitted via email no later than May 10, 2021, 10:00am. Email: percy.johnson2@va.gov Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, DUNS number and address, point of contact and social-economic. STATEMENT OF WORK (SOW) Triage Chairs Detroit VA Medical Center 4646 John R St, Detroit MI 48201 Scope The six EERs are a combination of required equipment replacements and services that will make up a partial service upgrade to renovate the Detroit VAMC Dental Suite. There are no �new� additions of equipment to what�s already in place. More specifically this task is to replace End of Life Cycle equipment in this service. EERs 124850 and 124851 are exclusive to the 19 exam and/or surgical chairs and the remaining 4 EERs (125962, 125982, 125983 and 125984) are precisely for the 25 designated exam rooms in this service which are C2426-C2429, C2433, C2437-C2439, C2440-C2441, C2443-CC2447, C2449, C2451-C2455, C2466, C2470, C2473, C2475, and C2477-C2478; consisting of X-Ray units (arms) and computers that work simultaneously for daily use. Therefore, the 23 replaced items MUST interconnect with � and � seamlessly function with the non-replaced equipment. ROOM TYPE Phase 1 Phase 2 Phase 3 PROJECT TOTAL DOCTOR 5 1 12 18 HYGIENE 0 3 0 3 TRIAGE 0 2 0 2 TOTAL/PHASE 5 6 12 23 The contractor shall provide all equipment in the stated quantities as referenced on each quote per EER. -The equipment will not be opened or received without the contractor�s presence to account for all purchased equipment. -Immediately following accountability and inspection of equipment, the service and contractor will coordinate installation. -Upon full installation and training the service shall inform the warehouse to completely receive each PO so that the vendor will get paid in a timely manner. Page 3 of 3 Technical Requirements Since there is still standing equipment in other areas of this service that is not being replaced at this time it is imperative that the contractor have qualified personnel, supervision, and equipment to accomplish work on schedule and to the satisfaction of the CO. Specifically, be able to identify, connect or resolve issues with the replaced equipment to the standing equipment for a seamless transition. Safety Requirements In the performance of this contract, the contractor shall take such safety precautions as may be determined to be reasonably necessary to protect the lives and health all staff and patients. Period of Performance Monitoring shall commence upon delivery and shall extend through installation and the conclusion of training.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/da344b35dece443083f93e5800d7e2bb/view)
- Place of Performance
- Address: Detroit, MI 48201, USA
- Zip Code: 48201
- Country: USA
- Zip Code: 48201
- Record
- SN05994643-F 20210508/210506230120 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |