SOLICITATION NOTICE
65 -- Notice of Intent to Sole Source Modular Hemodynamic Monitoring Platform
- Notice Date
- 5/6/2021 8:31:34 AM
- Notice Type
- Presolicitation
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- W4PZ USA MED RSCH ACQUIS ACT FORT DETRICK MD 21702-5014 USA
- ZIP Code
- 21702-5014
- Solicitation Number
- JA04-00297
- Response Due
- 5/21/2021 10:00:00 AM
- Archive Date
- 06/05/2021
- Point of Contact
- Kasey Carroll
- E-Mail Address
-
kasey.l.carroll.civ@mail.mil
(kasey.l.carroll.civ@mail.mil)
- Description
- THIS IS A NOTICE OF INTENT TO AWARD A SOLE-SOURCE CONTRACT AND IS NOT A REQUEST FOR COMPETITIVE PROPOSALS. The United Stated Army Medical Research Acquisition Activity (USAMRAA) intends to negotiate on a sole source basis, IAW FAR 13.106, with Edward Lifesciences One Edwards Way, Irvine CA 92614, USA, as the only responsible source that can provide the Modular Hemodynamic Monitoring Platform.� This acquisition is being conducted under FAR Part 12 Acquisition of Commercial Items. Provisions and clauses in effect through Federal Acquisition Circular 2021-04 are incorporated. The Walter Reed Army Institute Research � Center for Military Psychiatry and Neuroscience (WRAIR - CMPN) intends to procure a firm-fixed-price contract. The contractor shall be able to meet the following Minimum Essential Characteristics: REQUIREMENTS: Measuring System Parameters Monitor:For all monitoring modes and parameters No Interruption of current mode, unexpected reboots, halting of operations, or spontaneous triggering of events that require user interaction to initiate. Patient connections provide defibrillator protection. System returns to operational state within 10 seconds of defibrillator event or transient electromagnetic phenomena. Following transient electromagnetic phenomena, any stored data will not be lost. Swan-Ganz Module: Continuous Cardiac Output (CO) Intermittent Cardiac Output (iCO) Blood Temperature (BT) Injectate Temperature (IT) Continuous Right Ventricular Ejection Fraction (RVEF) Average Heart Rate for EDV/RVEF Determination (HRAvg) Pressure Cable: Cardiac Output (CO) IEC 60601-2-34 compliant Blood Pressure display Live pressure MAP/DIA/SYS CVP� MPAP Pulse Rate (PR) Oximetry Cable: ScvO2/SvO2 Oximetry (oxygen saturation) Tissue Oximetry Module: Cerebral StO2 (tissue oxygen saturation) Non-cerebral StO2 (tissue oxygen saturation) Hardware Touch screen, serial port, USB ports, Ethernet port, HDMI port, Analog inputs, pressure output, ECG monitor input. Swan-Ganz Module Pressure Cable Oximetry Cable Tissue Oximetry Module Calibration Automatic option Manual option Temperature 10-32 degrees C / 50-90 degrees F Power Voltage: 100 � 240 VAC, 50 � 60 Hz Input: 1.5 to 2.0 Amps Fuses: T2.5AH, 250V; High breaking capacity; Ceramic Dimensions 10 � 28 L x 20 � 18W� x�� 10 � 18H (inches) Weight 10 - 20 lbs The intended procurement will be classified under North American Industry Classification System (NAICS) 339112 with a Small Business Size Standard of 1000 employees. This notice of intent is not a request for competitive proposals and no solicitation document will be posted for this requirement. However, parties interested in responding to this notice shall submit technical data, including cost, sufficient to determine capability in providing the same product. All capability statements received by closing of this notification of this synopsis will be considered by the Government. A determination by the Government not to compete based on responses to this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. Submit email capabilities statements (using PDF, MS Word, Excel attachments) to Kasey Carroll at kasey.l.carroll.civ@mail.mil. Statements are due no later than 1:00 P.M. EST on 21 May 2021. Late responses will not be reviewed. ��
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/d5c5c232179945b099769e0111d3bcf3/view)
- Place of Performance
- Address: USA
- Country: USA
- Country: USA
- Record
- SN05994359-F 20210508/210506230118 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |