SOLICITATION NOTICE
48 -- 48--VALVE,REGULATING,FL, IN REPAIR/MODIFICATION OF
- Notice Date
- 4/8/2021 3:14:48 AM
- Notice Type
- Solicitation
- NAICS
- 333999
— All Other Miscellaneous General Purpose Machinery Manufacturing
- Contracting Office
- NAVSUP WEAPON SYSTEMS SUPPORT PHILADELPHIA PA 19111-5098 USA
- ZIP Code
- 19111-5098
- Solicitation Number
- N0038321RH308
- Response Due
- 5/10/2021 12:00:00 AM
- Archive Date
- 05/25/2021
- Point of Contact
- Telephone: 2156979780
- E-Mail Address
-
OLEG.MAKSIMCHUK@NAVY.MIL
(OLEG.MAKSIMCHUK@NAVY.MIL)
- Description
- ITEM UNIQUE IDENTIFICATION AND VALUATION (MAR 2016)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT|8||||||||| TIME OF DELIVERY (JUNE 1997)|20||||||||||||||||||||| STOP-WORK ORDER (AUG 1989)|1|| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (DEC 2018)|16|TBD||TBD|N00383|TBD|TBD|TBD|TBD||||||||| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|| EQUAL OPPORTUNITY (SEP 2016)|2||| SMALL BUSINESS SUBCONTRACTING PLAN (DOD CONTRACTS)- BASIC (DEC 2019)|2||| EQUAL OPPORTUNITY FOR VETERANS (JUN 2020)|4||||| WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUN 2003)|6|365 DAYS |45 days of the last delivery under this contract||||| SMALL BUSINESS SUBCONTRACTING PLAN (JUN 2020)|4||||| SAFEGUARDING SENSITIVE CONVENTIONAL ARMS, AMMUNITION, AND EXPLOSIVES (SEP 1999)|9|||||||||| EQUAL OPPORTUITY FOR WORKERS WITH DISABILITIES (JUN 2020)|2||| TRANSPORTATION OF SUPPLIES BY SEA (FEB 2019)|2||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM - BASIC(DEVIATION 2020-O0019) (JUL 2020))|3|||| LIMITATIONS ON PASS-THROUGH CHARGES (JUN 2020)|1|| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (NOV 2020)|13|||||||||||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE (DEVIATION 2020-O0019) (JUL 2020))|3|||| BUY AMERICAN--BALANCE OF PAYMENTS PROGRAM (NOV 2014)|1|| ROYALTY INFORMATION (APR 1984)|1|| ANNUAL REPRESENTATIONS AND CERTIFICATIONS (MAR 2020)|13|332919|750|||||||||||| TYPE OF CONTRACT (APR 1984)|1|| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PREPAREDNESS, ANDENERGY PROGRAM USE (APR 2008))|2||A1A| 1. SCOPE FOR PURPOSES UNDERSTOOD BY ALL APPROVED SOURCES, THIS ITEM IS TO BE OVERHAULED AND NOT REPAIRED. ANY INDICATION OF THE TERM REPAIR IS NOW REPLACED BY THE TERM OVERHAUL. THIS ITEM MUST BE OVERHAULED IAW: TECHNICAL MANUAL A1-555AC-410-020 1 September 2015 DEPOT MAINTENANCE WITH ILLUSTRATED PARTS BREAKDOWN SECONDARY BLEED AIR PRESSURE REGULATINGAND SHUTOFF VALVE PART NUMBERS 2770073-113 2770073-114 This manual provides depot level maintenance and Illustrated Parts Breakdown (IPB) information for the Secondary Bleed Air Pressure Regulating and Shutoff Valve, part numbers 2770073-113 and 2770073-114. 1.1 Articles to be furnished hereunder shall be repaired, tested andinspected in accordance with the terms and conditions specified in theRequirements Section of this document. 1.2 Unless expressly provided for elsewhere in this clause, equipment suchas fixtures, jigs, dies, patterns, mylars, special tooling, test equipment, orany other manufacturing aid required for the manufacture and/or testing of the subject item(s) will not be provided by the Government or any other source and is the sole responsibility of the contractor. The foregoing applies notwithstanding any reference to such equipment or the furnishing thereof that may be contained in any drawing or referenced specification. 1.3 The use of MIL-W-81381 wire in any item to be delivered under this procurement is prohibited. The foregoing prohibition applies notwithstanding any reference to MIL-W-81381 wire that may be made in any of the drawings or specifications for this procurement. SAE-AS22759 series wire shall be used in lieu of MIL-W-81381 wire, in any place where MIL-W-81381 wire is cited in this procurement. Any questions concerning this requirement should be directed to the Procuring Contracting Officer. 1.4 If MIL-STD-454 is referenced in the drawings or in the specification,the contractor is expected to show compliance with IPC/EIAJ-STD-001C Personnel performing tasks in accordance with IPC/EIAJ-STD-001C shall be trained and certified as requried by IPC/EIAJ-STD-001C paragraph 5.1.4. ITEM MUST BE OVERHAULED IAW STATEMENT OF WORK DATED 29 OCTOBER 2020. THIS IS A HARDCOPY AND CAN BE OBTAINED FROM R.HUGHES CODE N23.1 THE DD-1423 IS ALSO HARDCOPY 2. APPLICABLE DOCUMENTS DOCUMENT REF DATA=A1-555AC-410-020 | | | | |C| | | 3. REQUIREMENTS FOR PURPOSES UNDERSTOOD BY ALL APPROVED SOURCES, THIS ITEM IS TO BE OVERHAULED AND NOT REPAIRED. ANY INDICATION OF THE TERM REPAIR IS NOW REPLACED BY THE TERM OVERHAUL. THIS ITEM MUST BE OVERHAULED IAW: TECHNICAL MANUAL A1-555AC-410-020 1 September 2015 DEPOT MAINTENANCE WITH ILLUSTRATED PARTS BREAKDOWN SECONDARY BLEED AIR PRESSURE REGULATINGAND SHUTOFF VALVE PART NUMBERS 2770073-113 2770073-114 This manual provides depot level maintenance and Illustrated Parts Breakdown (IPB) information for the Secondary Bleed Air Pressure Regulating and Shutoff Valve, part numbers 2770073-113 and 2770073-114. ITEM MUST BE OVERHAULED IAW STATEMENT OF WORK DATED 29 OCTOBER 2020. THIS IS A HARDCOPY AND CAN BE OBTAINED FROM R.HUGHES CODE N23.1 THE DD-1423 IS ALSO HARDCOPY 4. QUALITY ASSURANCE FOR PURPOSES UNDERSTOOD BY ALL APPROVED SOURCES, THIS ITEM IS TO BE OVERHAULED AND NOT REPAIRED. ANY INDICATION OF THE TERM REPAIR IS NOW REPLACED BY THE TERM OVERHAUL. THIS ITEM MUST BE OVERHAULED IAW: TECHNICAL MANUAL A1-555AC-410-020 1 September 2015 DEPOT MAINTENANCE WITH ILLUSTRATED PARTS BREAKDOWN SECONDARY BLEED AIR PRESSURE REGULATINGAND SHUTOFF VALVE PART NUMBERS 2770073-113 2770073-114 This manual provides depot level maintenance and Illustrated Parts Breakdown (IPB) information for the Secondary Bleed Air Pressure Regulating and Shutoff Valve, part numbers 2770073-113 and 2770073-114. ITEM MUST BE OVERHAULED IAW STATEMENT OF WORK DATED 29 OCTOBER 2020. THIS IS A HARDCOPY AND CAN BE OBTAINED FROM R.HUGHES CODE N23.1 THE DD-1423 IS ALSO HARDCOPY THE FAT WILL BE PERFORMED AT THE CONTRACTORS FACILITY. 5. PACKAGING- MIL-STD 2073 PACKAGING APPLIES AS FOUND ELSEWHERE IN THE SCHEDULE 6. NOTES - NOT APPLICABLE DATE OF FIRST SUBMISSION=ASREQ DATE OF SUBSEQUENT SUBMISSION=ASREQ A REQUEST FOR VARIANCE IS REQUIRED FOR ANY DEVIATION OR WAIVER ENCOUNTERED DURING ANY PORTION OF MANUFACTURE. THIS MUST BE ROUTED TO THE ACO AND DCMA-OFFICE. THE FORM IS DD-1694 AND THE DCMA SHALL PROVIDE A FORM DD-1698.THE RFV MUST GO TO THE CONTRACTING OFFICER AT NAVSUP WSS FOR REVIEW AND THEN FORWARDED TO THE BASIC DESIGN ENGINEER FOR REVIEW AND DETERMINATION.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/e85d312c625147a6bd6c117302d186f2/view)
- Record
- SN05966667-F 20210410/210408230110 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |