Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 23, 2020 SAM #6964
SOLICITATION NOTICE

J -- Building Automation Services

Notice Date
12/21/2020 10:23:26 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
248-NETWORK CONTRACT OFFICE 8 (36C248) TAMPA FL 33637 USA
 
ZIP Code
33637
 
Solicitation Number
36C24821Q0119
 
Response Due
12/26/2020 7:00:00 AM
 
Archive Date
01/25/2021
 
Point of Contact
Rafael Rodriguez, Contract Specialist, Phone: 787-781-8700
 
E-Mail Address
Rafael.Rodriguez2@va.gov
(Rafael.Rodriguez2@va.gov)
 
Awardee
null
 
Description
5. PROJECT NUMBER (if applicable) CODE 7. ADMINISTERED BY 2. AMENDMENT/MODIFICATION NUMBER CODE 6. ISSUED BY 8. NAME AND ADDRESS OF CONTRACTOR 4. REQUISITION/PURCHASE REQ. NUMBER 3. EFFECTIVE DATE 9A. AMENDMENT OF SOLICITATION NUMBER 9B. DATED PAGE OF PAGES 10A. MODIFICATION OF CONTRACT/ORDER NUMBER 10B. DATED BPA NO. 1. CONTRACT ID CODE FACILITY CODE CODE Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods: The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers E. IMPORTANT: is extended, (a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended. 12. ACCOUNTING AND APPROPRIATION DATA (REV. 11/2016) is required to sign this document and return ___________ copies to the issuing office. is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A. 15C. DATE SIGNED B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b). RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified. C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF: D. OTHER Contractor 16C. DATE SIGNED 14. DESCRIPTION OF AMENDMENT/MODIFICATION 16B. UNITED STATES OF AMERICA Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect. 15A. NAME AND TITLE OF SIGNER 16A. NAME AND TITLE OF CONTRACTING OFFICER 15B. CONTRACTOR/OFFEROR STANDARD FORM 30 PREVIOUS EDITION NOT USABLE Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.) (Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.) (If required) (SEE ITEM 11) (SEE ITEM 13) (X) CHECK ONE 13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS, IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14. 11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT (Signature of person authorized to sign) (Signature of Contracting Officer) 0001 12/21/2020 None 36C248 Department of Veterans Affairs Network Contracting Office 8 (NCO 8) VA Caribbean HCS (Admin Bldg) #10 Calle Casia Suite #4M440 San Juan PR 00921-3201 36C248 Department of Veterans Affairs Network Contracting Office 8 (NCO 8) VA Caribbean HCS (Admin Bldg) #10 Calle Casia Suite #4M440 San Juan PR 00921-3201 To all Offerors/Bidders 36C24821Q0119 12-21-2020 X x 1 Title; PM Building Automation System 1) Please refer to page number two (2) for answers from questions submitted by interested Contractors. Rafael Rodriguez Contracting Officer VA-VHA-2019-3C9E1171 Page 8 of 8 Please provide the quantity of existing VFD s to be included in the contract along with their brand and size in Horse Power Answer to question 1: Variable Frequency Drive Inventory Table Item Unit Location Size Brand Serial no. 8 1 AHU 1 Return Fan SBT Machinery Room 7.5 Johnson Controls 12797518 INPUT: 480V 3 Phase 50/60HZ 11 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 11 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 2 AHU 1 Supply Fan SBT Machinery Room 40 Johnson Controls 12797514 INPUT: 480V 3 PHASE 50/60HZ 52 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 52 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 3 AHU 2 Supply Fan SBT Machinery Room 40 Johnson Controls 12797506 INPUT: 480V 3 PHASE 50/60HZ 52 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 52 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 4 AHU 2 Return Fan SBT Machinery Room 7.5 Johnson Controls 12797376 INPUT: 480V 3 PHASE 50/60HZ 11 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 11 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 5 AHU 3 Supply Fan SBT Machinery Room 40 Johnson Controls 12797512 INPUT: 480V 3 PHASE 50/60HZ 52 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 52 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 6 AHU 3 Return Fan SBT Machinery Room 7.5 Johnson Controls 12807344 INPUT: 480V 3 PHASE 50/60HZ 11 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 11 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 7 AHU 4 Supply Fan SBT Machinery Room 40 Johnson Controls 12797511 INPUT: 480V 3 PHASE 50/60HZ 52 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 52 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 8 AHU 4 Return Fan SBT Machinery Room 7.5 Johnson Controls 12797387 INPUT: 480V 3 PHASE 50/60HZ 11 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 11 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 9 AHU 5 Supply Fan SBT Machinery Room 40 Johnson Controls 12797507 INPUT: 480V 3 PHASE 50/60HZ 52 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 52 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 10 AHU 5 Return Fan SBT Machinery Room 10 Johnson Controls 12797193 INPUT: 480V 3 PHASE 50/60HZ 14 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 14 A RMS MAX AMBIENT : 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 11 AHU 6 Supply Fan SBT Machinery Room 50 Johnson Controls 12797173 INPUT: 480V 3 PHASE 50/60HZ 65 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 65 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 12 AHU 6 Return Fan SBT Machinery Room 7.5 Johnson Controls 12797436 INPUT: 480V 3 PHASE 50/60HZ 11 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 11 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 13 AHU 7 Supply Fan SBT Machinery Room 40 Johnson Controls 12797503 INPUT: 480V 3 PHASE 50/60HZ 52 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 52 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 14 AHU 7 Return Fan SBT Machinery Room 10 Johnson Controls 12797192 INPUT: 480V 3 PHASE 50/60HZ 14 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 14 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 15 AHU 8 Supply Fan SBT Machinery Room 40 Johnson Controls 12797501 INPUT: 480V 3 PHASE 50/60HZ 52 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 52 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 16 AHU 8 Return Fan SBT Machinery Room 5 Johnson Controls 12797194 INPUT: 480V 3 PHASE 50/60HZ 7.6 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 7.6 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 17 AHU 9 Supply Fan SBT Machinery Room 40 Johnson Controls 12797515 INPUT: 480V 3 PHASE 50/60HZ 52 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 52 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 18 AHU 9 Return Fan SBT Machinery Room 7.5 Johnson Controls 12797517 INPUT: 480V 3 PHASE 50/60HZ 11 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 11 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 19 AHU 10 Supply Fan SBT Machinery Room 40 Johnson Controls 12797509 INPUT: 480V 3 PHASE 50/60HZ 52 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 52 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 20 AHU 10 Return Fan SBT Machinery Room 7.5 Johnson Controls 12797504 INPUT: 480V 3 PHASE 50/60HZ 11 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 11 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 21 AHU 11 Supply Fan SBT Machinery Room 40 Johnson Controls 12797510 INPUT: 480V 3 PHASE 50/60HZ 52 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 52 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 22 AHU 11 Return Fan SBT Machinery Room 7.5 Johnson Controls 12797370 INPUT: 480V 3 PHASE 50/60HZ 11 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 11 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 23 AHU 12 Supply Fan SBT Machinery Room 40 Johnson Controls 12797505 INPUT: 480V 3 PHASE 50/60HZ 52 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 52 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 24 AHU 12 Return Fan SBT Machinery Room 7.5 Johnson Controls 12797390 INPUT: 480V 3 PHASE 50/60HZ 11 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 11 A RMS MAX AMBIENT : 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 25 Cooling Tower #2 SBT Machinery Room 50 Johnson Controls 12796894 INPUT: 480V 3 PHASE 50/60HZ 65 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 65 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 26 Cooling Tower #1 SBT Machinery Room 50 Johnson Controls 12796906 INPUT: 480V 3 PHASE 50/60HZ 65 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 65 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 27 IEF - 6 SBT Machinery Room 7.5 Johnson Controls 12797166 INPUT: 480V 3 PHASE 50/60HZ 11 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 11 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 28 IEF - 5 SBT Machinery Room 7.5 Johnson Controls 12797179 INPUT: 480V 3 PHASE 50/60HZ 11 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 11 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 29 IEF - 4 SBT Machinery Room 3 Johnson Controls 12797196 INPUT: 480V 3 PHASE 50/60HZ 4.8 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 4.8 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 30 IEF - 3 SBT Machinery Room 7.5 Johnson Controls 12797198 INPUT: 480V 3 PHASE 50/60HZ 11 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 11 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 31 IEF - 2 SBT Machinery Room 10 Johnson Controls 12797185 INPUT: 480V 3 PHASE 50/60HZ 14 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 14 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 32 IEF - 1 SBT Machinery Room 7.5 Johnson Controls 12797195 INPUT: 480V 3 PHASE 50/60HZ 11 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 11 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 33 EF Outside Air SBT Machinery Room 15 EMERSON B4015-21300 FREQUENCY IN/OUT 21 AFLC, VOLTS IN/OUT 460 VAC 34 Hot Water Pump - 1 SBT Machinery Room 20 Johnson Controls 12797213 INPUT: 480V 3 PHASE 50/60HZ 27 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 27 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 35 Hot Water Pump - 2 SBT Machinery Room 20 Johnson Controls 12890581 INTELLIPASS OPTIONS: 3, INPUT: 480VAC 50/60HZ 27A 3PH, OUTPUT: 0-480VAC 0-320HZ 27A 3PH, MAX HP: 20HP @ 480VAC 27A, CONTROL: 24VDC, MAX AMBIENT TEMP: 40 C, ENCLOSURE TYPE: 12, SHORT CIRCUIT RATINGS: 65KA @ 480Y/277VAC, SCHEMATIC: 285447-1004 36 Cooling Tower Pump - 1 SBT Machinery Room 50 DANFOSS 293702Y407 INPUT: 3, 460 VAC, 60HZ, 65 A, OUTPUT: 3, 0-460 VAC, 0-60HZ, 65A, POWER 50 HP, 37 KW, SHORT CIRCUIT RASTING: 5KA RMS SYM. AT RATED INPUT V MAX., MAX. AMBIENT: 40 C/ 104 F, MIN AMBIENT: -10C / 14F 37 Cooling Tower Pump - 2 SBT Machinery Room 50 DANFOSS 293502Y407 INPUT: 3, 460 VAC, 60HZ, 65 A, OUTPUT: 3, 0-460 VAC, 0-60HZ, 65A, POWER 50 HP, 37 KW, SHORT CIRCUIT RASTING: 5KA RMS SYM. AT RATED INPUT V MAX., MAX. AMBIENT: 40 C/ 104 F, MIN AMBIENT: -10C / 14F 38 Cooling Tower Pump -3 SBT Machinery Room 10 DANFOSS 315804Y407 INPUT POWER: 480 VAC, 14.3 A, 3, 60HZ, MOTOR: 460 VAC, 10 HP, 14.0 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 39 Chill Water Pump - 1 SBT Machinery Room 60 Johnson Controls 12797090 INPUT: 480V 3 PHASE 50/60HZ 77 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 77 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 40 Chill Water Pump - 2 SBT Machinery Room 60 Johnson Controls 12797112 INPUT: 480V 3 PHASE 50/60HZ 77 A RMS OUTPUT: 0 TO 480V 3 PHASE 1 TO 320 HZ 77 A RMS MAX AMBIENT: 40 DEG. C OVERLOAD: 1.10 ENCLOSURE: NEMA TYPE 12W / INTELLIPASS MANUFACTURE BY EATON ELECTRICAL 41 AHU 12 Supply Fan OPA PH Machinery Room 50 TRANE 755404Y262 INPUT POWER: 480 VAC, 65.6 A, 3, 60HZ, MOTOR: 460 VAC, 50.00 HP, 65.0 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 42 AHU 12 Return Fan OPA PH Machinery Room 15 TRANE 757804Y263 INPUT POWER: 480 VAC, 21.3 A, 3, 60HZ, MOTOR: 460 VAC, 15.00 HP, 21.0 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 43 AHU 03 Supply Fan OPA PH Machinery Room 50 TRANE 755304Y262 INPUT POWER: 480 VAC, 65.6 A, 3, 60HZ, MOTOR: 460 VAC, 50.00 HP, 65.0 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 44 AHU 03 Return Fan OPA PH Machinery Room 15 TRANE 757704Y262 INPUT POWER: 480 VAC, 21.3 A, 3, 60HZ, MOTOR: 460 VAC, 15.00 HP, 21.0 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 45 AHU 04 Supply Fan OPA PH Machinery Room 40 TRANE 750204Y262 INPUT POWER: 480 VAC, 52.6 A, 3, 60HZ, MOTOR: 460 VAC, 40.00 HP, 52.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 46 AHU 04 Return Fan OPA PH Machinery Room 15 TRANE 757904Y262 INPUT POWER: 480 VAC, 21.3 A, 3, 60HZ, MOTOR: 460 VAC, 15.00 HP, 21.0 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 47 AHU - 100 OPA PH Machinery Room 5 TRANE 751404Y262 INPUT POWER: 480 VAC, 7.9 A, 3, 60HZ, MOTOR: 460 VAC, 5.00 HP, 7.9 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 48 AHU 14 Supply  Fan OPA PH Machinery Room 20 TRANE 757204Y262 INPUT POWER: 480 VAC, 27.3 A, 3, 60HZ, MOTOR: 460 VAC, 20.00 HP, 27.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 49 AHU 14 Return Fan OPA PH Machinery Room 7.5 TRANE 750804Y262 INPUT POWER: 480 VAC, 11.3 A, 3, 60HZ, MOTOR: 460 VAC, 7.5.00 HP, 11.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 50 AHU - 4A OPA PH Machinery Room 3 TRANE 751604Y262 INPUT POWER: 480 VAC, 5.1 A, 3, 60HZ, MOTOR: 460 VAC, 20.00 HP, 5.1 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 51 AHU 16 Supply Fan OPA PH Machinery Room 50 TRANE 755204Y262 INPUT POWER: 480 VAC, 65.6 A, 3, 60HZ, MOTOR: 460 VAC, 50.00 HP, 65.0 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 52 AHU 16 Return Fan OPA PH Machinery Room 15 TRANE 757604Y262 INPUT POWER: 480 VAC, 21.3 A, 3, 60HZ, MOTOR: 460 VAC, 15.00 HP, 21.0 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 53 AHU 15 Supply Fan OPA PH Machinery Room 20 TRANE 757104Y262 INPUT POWER: 480 VAC, 27.3 A, 3, 60HZ, MOTOR: 460 VAC, 20.00 HP, 27.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 54 AHU 15 Return Fan OPA PH Machinery Room 5 TRANE 751504Y262 INPUT POWER: 480 VAC, 7.9 A, 3, 60HZ, MOTOR: 460 VAC, 5.00 HP, 7.9 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 55 AHU 1 Supply Fan OPA PH Machinery Room 50 TRANE 755104Y262 INPUT POWER: 480 VAC, 65.6 A, 3, 60HZ, MOTOR: 460 VAC, 50.00 HP, 65.0 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 56 AHU 1 Return Fan OPA PH Machinery Room 20 TRANE 757304Y262 INPUT POWER: 480 VAC, 27.3 A, 3, 60HZ, MOTOR: 460 VAC, 20.00 HP, 27.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 57 AHU 2 Supply Fan OPA PH Machinery Room 25 TRANE 756304Y262 INPUT POWER: 480 VAC, 34.3 A, 3, 60HZ, MOTOR: 460 VAC, 25.00 HP, 34.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 58 AHU 2 Return Fan OPA PH Machinery Room 10 TRANE 751204Y262 INPUT POWER: 480 VAC, 14.3 A, 3, 60HZ, MOTOR: 460 VAC, 10.00 HP, 14.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 59 AHU 6 Supply Fan OPA PH Machinery Room 40 TRANE 554604Y232 INPUT POWER: 480 VAC, 52.6 A, 3, 60HZ, MOTOR: 460 VAC, 40.00 HP, 52.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 60 AHU 6 Return Fan OPA PH Machinery Room 25 TRANE 552104Y232 INPUT POWER: 480 VAC, 34.3 A, 3, 60HZ, MOTOR: 460 VAC, 25.00 HP, 34.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 61 AHU 5 Supply Fan OPA PH Machinery Room 60 TRANE 534904Y232 INPUT POWER: 480 VAC, 77.6 A, 3, 60HZ, MOTOR: 460 VAC, 60.00 HP, 77.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 62 AHU 5 Return Fan OPA PH Machinery Room 30 TRANE 542904Y232 INPUT POWER: 480 VAC, 40.6 A, 3, 60HZ, MOTOR: 460 VAC, 30.00 HP, 40.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 63 AHU 18 Supply Fan OPA PH Machinery Room 25 TRANE 756504Y262 INPUT POWER: 480 VAC, 34.3 A, 3, 60HZ, MOTOR: 460 VAC, 25.00 HP, 34.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 64 AHU 18 Return Fan OPA PH Machinery Room 7.5 TRANE 751004Y262 INPUT POWER: 480 VAC, 11.3 A, 3, 60HZ, MOTOR: 460 VAC, 7.5.00 HP, 11.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 65 AHU 17 Supply Fan OPA PH Machinery Room 50 TRANE 755504Y262 INPUT POWER: 480 VAC, 65.6 A, 3, 60HZ, MOTOR: 460 VAC, 50.00 HP, 65.0 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 66 AHU 17 Return Fan OPA PH Machinery Room 15 TRANE 757504Y262 INPUT POWER: 480 VAC, 21.3 A, 3, 60HZ, MOTOR: 460 VAC, 15.00 HP, 21.0 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 67 AHU 7 Supply Fan OPA PH Machinery Room 60 TRANE 758404Y262 INPUT POWER: 480 VAC, 77.6 A, 3, 60HZ, MOTOR: 460 VAC, 60.00 HP, 77.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 68 AHU 7 Return Fan OPA PH Machinery Room 25 TRANE 756404Y262 INPUT POWER: 480 VAC, 34.3 A, 3, 60HZ, MOTOR: 460 VAC, 25.00 HP, 34.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 69 AHU 52 Supply Fan OPA PH Machinery Room 25 TRANE 756704Y262 INPUT POWER: 480 VAC, 34.3 A, 3, 60HZ, MOTOR: 460 VAC, 25.00 HP, 34.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 70 AHU 19 Supply Fan OPA PH Machinery Room 25 TRANE 756204Y262 INPUT POWER: 480 VAC, 34.3 A, 3, 60HZ, MOTOR: 460 VAC, 25.00 HP, 34.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5 KA RMS SYM. AT RATED INPUT V MAX. 71 AHU 19 Return Fan OPA PH Machinery Room 10 TRANE 751104Y262 INPUT POWER: 480 VAC, 14.3 A, 3, 60HZ, MOTOR: 460 VAC, 10.00 HP, 14.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 72 AHU - 101 OPA PH Machinery Room 3 TRANE 751704Y262 INPUT POWER: 480 VAC, 5.1 A, 3, 60HZ, MOTOR: 460 VAC, 3.00 HP, 5.1 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 73 AHU 8 Supply Fan OPA PH Machinery Room 60 TRANE 758504Y262 INPUT POWER: 480 VAC, 77.6 A, 3, 60HZ, MOTOR: 460 VAC, 60.00 HP, 77.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 74 AHU 8 Return Fan OPA PH Machinery Room 25 TRANE 756604Y262 INPUT POWER: 480 VAC, 34.3 A, 3, 60HZ, MOTOR: 460 VAC, 25.00 HP, 34.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 75 AHU 21 Supply Fan OPA PH Machinery Room 25 TRANE 003207H422 INPUT: 3, 460 VAC, 60HZ, 34.0A FLA, OUTPUT: 3, 3-460 VAC, 0-60 HZ, 34.0A FLA, POWER: 25HP, 18.5 KW 76 AHU 21 Return Fan OPA PH Machinery Room 7.5 TRANE 750904Y262 INPUT POWER: 480 VAC, 11.3 A, 3, 60HZ, MOTOR: 460 VAC, 7.5.00 HP, 11.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 77 AHU 20 Supply Fan OPA PH Machinery Room 25 TRANE 756804Y262 INPUT POWER: 480 VAC, 34.3 A, 3, 60HZ, MOTOR: 460 VAC, 25.00 HP, 34.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 78 AHU 20 Return Fan OPA PH Machinery Room 5 TRANE 751304Y262 INPUT POWER: 480 VAC, 7.9 A, 3, 60HZ, MOTOR: 460 VAC, 5.00 HP, 7.9 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 79 Cooling Tower #1 OPA PH Machinery Room 30 TRANE 542604Y232 INPUT POWER: 480 VAC, 40.6 A, 3, 60HZ, MOTOR: 460 VAC, 30.00 HP, 40.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 80 Cooling Tower #2 OPA PH Machinery Room 30 TRANE 543004Y233 INPUT POWER: 480 VAC, 40.6 A, 3, 60HZ, MOTOR: 460 VAC, 30.00 HP, 40.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5 KA RMS SYM. AT RATED INPUT V MAX. 81 Cooling Tower #3 OPA PH Machinery Room 30 TRANE 542804Y232 INPUT POWER: 480 VAC, 40.6 A, 3, 60HZ, MOTOR: 460 VAC, 30.00 HP, 40.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 82 Cooling Tower #4 OPA PH Machinery Room 30 TRANE 542704Y232 INPUT POWER: 480 VAC, 40.6 A, 3, 60HZ, MOTOR: 460 VAC, 30.00 HP, 40.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 83 Pump - 11 OPA Basement Machinery Room 50 TRANE 562004Y082 INPUT POWER: 480 VAC, 65.6 A, 3, 60HZ, MOTOR: 460 VAC, 50.00 HP, 65.0 A, 3, 60HZ, SHORT CIRCUIT RATING: 5 KA RMS SYM. AT RATED INPUT V MAX. 84 AHU 13 Supply Fan OPA Basement Machinery Room 10 TRANE 499704Y072 INPUT POWER: 480 VAC, 14.3 A, 3, 60HZ, MOTOR: 460 VAC, 10.00 HP, 14.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 85 Pump - 7 OPA Basement Machinery Room 60 TRANE 562204Y082 INPUT POWER: 480 VAC, 77.6 A, 3, 60HZ, MOTOR: 460 VAC, 60.00 HP, 77.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 86 Pump - 8 OPA Basement Machinery Room 60 TRANE 562104Y082 INPUT POWER: 480 VAC, 77.6 A, 3, 60HZ, MOTOR: 460 VAC, 60.00 HP, 77.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 87 Pump - 9 OPA Basement Machinery Room 20 TRANE 559504Y082 INPUT POWER: 480 VAC, 27.3 A, 3, 60HZ, MOTOR: 460 VAC, 20.00 HP, 27.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 88 Pump - 10 OPA Basement Machinery Room 20 TRANE 559404Y082 INPUT POWER: 480 VAC, 27.3 A, 3, 60HZ, MOTOR: 460 VAC, 20.00 HP, 27.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 89 Pump - 18 OPA Basement Machinery Room 15 TRANE 004007H442 INPUT: 3, 460 VAC, 60HZ, 21.0A FLA, OUTPUT: 3, 3-460 VAC, 0-60 HZ, 21.0A FLA, POWER: 15HP, 18.5 KW 90 Pump - 17 OPA Basement Machinery Room 15 TRANE 003907H442 INPUT: 3, 460 VAC, 60HZ, 21.0A FLA, OUTPUT: 3, 3-460 VAC, 0-60 HZ, 21.0A FLA, POWER: 15HP, 18.5 KW 91 Pump - 16 OPA Basement Machinery Room 40 TRANE 548804Y072 INPUT POWER: 480 VAC, 52.6 A, 3, 60HZ, MOTOR: 460 VAC, 40.00 HP, 52.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 92 AHU 5 Supply Fan Admin Bldg. PH Machinery Room 30 Johnson Controls 2103303731 45 A, 30HP, VOLT 480 VAC 93 AHU 5 Return Fan Admin Bldg. PH Machinery Room 10 Johnson Controls 2110102946 15.4 A, 10 HP, VOLT 480 VAC 94 AHU 4 Supply Fan Admin Bldg. PH Machinery Room 40 Johnson Controls 2110100765 INPUT: 3PH 48 63 HZ, VOLTAGE(U1) 380 480 VAC, CURRENT(L1N) 58A 95 AHU 4 Return Fan Admin Bldg. PH Machinery Room 10 Johnson Controls 2122400934 15 A, 10 HP, VOLT 480 VAC 96 AHU 3 Supply Fan Admin Bldg. PH Machinery Room 40 Johnson Controls 2104002131 INPUT: 3PH 48 63 HZ, VOLTAGE(U1) 380 480 VAC, CURRENT(L1N) 58A 97 AHU 3 Return Fan Admin Bldg. PH Machinery Room 15 Johnson Controls 2105003602 15 A, 10 HP, VOLT 480 VAC 98 AHU 2 Supply Fan Admin Bldg. PH Machinery Room 40 Johnson Controls 2106200645 50 A, 40 HP, VOLT 480 VAC 99 AHU 2 Return Fan Admin Bldg. PH Machinery Room 10 Johnson Controls S/N IS NOT CLEAR VOLT: 460, AMP: 12.5, 60HZ, PHASE 3 100 AHU 1 Supply Fan Admin Bldg. Basement Machinery Room 40 Johnson Controls 2105200639 INPUT: 3PH 48 63 HZ, VOLTAGE(U1) 380 480 VAC, CURRENT(L1N) 58A 101 AHU 1 Return Fan Admin Bldg. Basement Machinery Room 10 Johnson Controls   INPUT: 3PH 48 63 HZ, VOLTAGE(U1) 380 480 VAC, CURRENT(L1N) 15.4A 102 Supply Fan 8 Admin Bldg. Basement Machinery Room 7.5 ABB   INPUT: 3PH 48 63 HZ, VOLTAGE(U1) 380 480 VAC, CURRENT(L1N) 11.9A 103 AHU - Breezeway Bldg. 1 Roof 5 TRANE 569902G283 4.0KW(400V), 5.0HP(460), IN: 3X380-480V 50/60HZ 9.1/8.3A, OUT: 3X0-VIN 0-1000HZ 10/8.2A 104 EF - 88 Bldg. 1 Roof 15 DANFOSS 009833H397 11KW / 15HP, IN: 3X380-480V 50/60HZ 22/19A, OUT: 3X0-VIN 0-590HZ 24/21A 105 AHU - S2R Bldg. 1 Roof 30 TRANE 658304Y144 INPUT POWER: 480 VAC, 40.6 A, 3, 60HZ, MOTOR: 460 VAC, 30.00 HP, 40.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 106 AHU Lineal Accelerator A 1 CT Scan Bldg. Roof 7.5 TRANE 861000Y085 INPUT POWER: 480 VAC, 10.6 A, 3, 60HZ, MOTOR: 460 VAC, 7.5.00 HP, 10.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 107 AHU Lineal Accelerator A 1A CT Scan Bldg. Roof 7.5 TRANE 789400Y075 INPUT POWER: 480 VAC, 10.6 A, 3, 60HZ, MOTOR: 460 VAC, 7.5.00 HP, 10.6 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 108 SF - 3 Bldg. 1 2nd Floor Roof 25 Johnson Controls 2093202587 VOLT: 460, AMPS: 30, 25HP, 60HZ 109 SF - 6 Bldg. 1 2nd Floor Roof 25 Johnson Controls 2093000437 VOLT: 460, AMPS: 30, 25HP, 60HZ 110 AHU - 10 Bldg. 1 2nd Floor Roof   ABB 2154201314 VOLT: 277/480, 3 PHASE, 11.9A, 63HZ 111 SF - 4 Bldg. 1 2nd Floor Roof 25 Johnson Controls 2093000418 VOLT: 460, AMPS: 30, 25HP, 60HZ 112 SF - 5 Bldg. 1 2nd Floor Roof 25 Johnson Controls 2092800522 VOLT: 460, AMPS: 30, 25HP, 60HZ 113 AHU - 1 CLC 1st Floor Machinery Room 15 TRANE 001329H215 IN: 3X200-240V 50/60HZ, 48.3A, OUT: 3X0-VIN 0.1-1000HZ, 48.3A, 11KW / 15HP 114 AHU - 2 CLC 2nd Floor Machinery Room 25 TRANE 000529H205 IN: 3X200-240V 50/60HZ, 78.2A, OUT: 3X0-VIN 0.1-1000HZ, 78.2A, 18.5KW / 15HP 115 AHU - 3 CLC 1st Floor Machinery Room 10 TRANE 000529H215 IN: 3X200-240V 50/60HZ, 32.2A, OUT: 3X0-VIN 0.1-1000HZ, 33A, 7.5KW / 10HP 116 AHU - 4 CLC 1st Floor Machinery Room 5 TRANE 000429H205 IN: 3X200-240V 50/60HZ, 16.8A, OUT: 3X0-VIN 0.1-1000HZ, 17.6A, 3.7KW / 5HP 117 AHU- Ambulatory Surgery Bldg.1 1st Floor Roof 10 ABB 51737C0330 3-380 480V, 31A, 48 63HZ,10HP 118 Pump 10 Potable Water Pump Room 25 TRANE 803204Y415 INPUT POWER: 480 VAC, 34.3 A, 3, 60HZ, MOTOR: 460 VAC, 25.00 HP, 34.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 119 Pump 9 Potable Water Pump Room 25 TRANE   INPUT POWER: 480 VAC, 34.3 A, 3, 60HZ, MOTOR: 460 VAC, 25.00 HP, 34.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 120 Pump 8 Potable Water Pump Room 25 TRANE   INPUT POWER: 480 VAC, 34.3 A, 3, 60HZ, MOTOR: 460 VAC, 25.00 HP, 34.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 121 Pump 7 Potable Water Pump Room 25 TRANE 803104Y415 INPUT POWER: 480 VAC, 34.3 A, 3, 60HZ, MOTOR: 460 VAC, 25.00 HP, 34.3 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 122 Cooling Tower 1 Main Chiller Plant 75 TRANE 614004Y111 INPUT POWER: 480 VAC, 96.8 A, 3, 60HZ, MOTOR: 460 VAC, 75.00 HP, 96.8 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 123 Cooling Tower 2 Main Chiller Plant 75 TRANE 613904Y111 INPUT POWER: 480 VAC, 96.8 A, 3, 60HZ, MOTOR: 460 VAC, 75.00 HP, 96.8 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 124 Cooling Tower 3 Main Chiller Plant 75 TRANE 613804Y111 INPUT POWER: 480 VAC, 96.8 A, 3, 60HZ, MOTOR: 460 VAC, 75.00 HP, 96.8 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 125 Cooling Tower 4 Main Chiller Plant 75 TRANE 614104Y111 INPUT POWER: 480 VAC, 96.8 A, 3, 60HZ, MOTOR: 460 VAC, 75.00 HP, 96.8 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 126 Cooling Tower 5 Main Chiller Plant 75 TRANE 613704Y111 INPUT POWER: 480 VAC, 96.8 A, 3, 60HZ, MOTOR: 460 VAC, 75.00 HP, 96.8 A, 3, 60HZ, SHORT CIRCUIT RATING: 5KA RMS SYM. AT RATED INPUT V MAX. 127 PUMP 1R Main Chiller Plant 20 DANFOSS 007833H387 15KW/20HP, 50/60HZ, 29/25A 128 PUMP 2R Main Chiller Plant 20 DANFOSS 295404Y407 15KW/20HP, 50/60HZ, 29/25A 129 PUMP 3R Main Chiller Plant 20 DANFOSS 295604Y407 15KW/20HP, 50/60HZ, 29/25A 130 PUMP 4R Main Chiller Plant 20 DANFOSS 295704Y407 15KW/20HP, 50/60HZ, 29/25A 131 PUMP 12R Main Chiller Plant 150 TRANE 001203H255 110KW/150HP, 50/60HZ,204/183A 132 PUMP 10R Main Chiller Plant 150 TRANE 001103H255 110KW/150HP, 50/60HZ,204/183A 133 PUMP 11R Main Chiller Plant 150 TRANE 001003H255 110KW/150HP, 50/60HZ,204/183A Are any of the VFDs damaged and what s their brand and capacity? Answer to question 2: OPA Building AHU 15 Supply Fan 20 HP Out of service AHU 53 Supply Fan 10 HP Out of Service AHU 4 Return Fan 15 HP Out of service AHU 17 Return Fan 15 HP Out of service SBT Building AHU 5 Supply Fan 30 HP Out of service AHU 10 Supply Fan 40 HP Out of service AHU 3 Return Fan 7.5 HP Out of service AHU 1 Return Fan 7.5 HP Out of service Hot Water Pump 2 15 HP Out of service Main Building Pump 7 Millionaires Tanks 25 HP Out of service Pump 8 Millionaires Tanks 25 HP Out of service Pump 9 Millionaires Tanks 25 HP Out of service Pump 10 Millionaires Tanks 25 HP Out of service Administration Building AHU 1 Return Fan Out of service Please provide the quantity of BCUs, UPCMs, MPs, FECs, NAEs, JACEs and Distech Controllers. Answer to question 3: Five Network Automation Engines or NAE. Twenty three Field Equipment Controllers of FEC. Forty nine FEC expansion cards. One Java Application Control Engine or JACE. Eleven Distech controllers 11. Twenty nine Building Control Units or BCU. Fifty four Universal Programable Control Modules or UPCMs. One hundred and ninety-seven Multi-Purpose controllers or MP. Three hundred and fifty five  MP expansion cards. Please indicate if there are any of the above-mentioned controllers that are non-operational. Answer to question 4: One UPCM is out of service. Please indicate if there are any of the above-mentioned controllers that are non-operational. Answer to question 5:            Yes, the contractor is responsible for any part that need replacement during the contract period. Please indicate if calibrations will be allowed during normal working hours on all areas of the facilities or if the contractor will have to perform calibrations of sensitive areas during non-normal working hours. Answer to question 6:           Contractor will perform all recurring maintenance on scheduled with final customer systematically.  Recurring mainten...
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/23b347e047ce4c8eb8078116d38846d5/view)
 
Place of Performance
Address: 10 Casia Street, San Juan 00921
Zip Code: 00921
 
Record
SN05878547-F 20201223/201221230109 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.