Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF DECEMBER 18, 2020 SAM #6959
SOURCES SOUGHT

99 -- Cullum Hall Repair Building 605

Notice Date
12/16/2020 6:15:21 AM
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
New York New York NY 10278-0090
 
ZIP Code
10278-0090
 
Solicitation Number
W912DS21S0013
 
Response Due
1/31/2021 11:00:00 AM
 
Archive Date
02/15/2021
 
Point of Contact
Nicole C. Fauntleroy, Phone: 9177906139, Nicholas P. Emanuel, Phone: 9177908069
 
E-Mail Address
nicole.fauntleroy@usace.army.mil, Nicholas.P.Emanuel@usace.army.mil
(nicole.fauntleroy@usace.army.mil, Nicholas.P.Emanuel@usace.army.mil)
 
Description
The U.S. Army Corps of Engineers, New York District is issuing this Sources Sought Notice to determine if there is an adequate number of small business firms (e.g. 8(a), HUBZone SB, SDVOSB, WOSB/EDWOSB) having the capability and bonding capacity for the following effort. The procurement method for this solicitation will be an invitation for bids. �Project magnitude is between $25 million and $100 million. SCOPE OF WORK: Repair Cullum Hall, building number 605. Cullum Hall was built in 1898 and is 41,344 square feet in size. This project is needed for the United States Military Academy (USMA) Library, Special Collections and Archives Division (Archives), United States Army Garrison (USAG) West Point. Cullum Hall is failing and is unable to meet Archives' specific academic and technical operational mission requirements. Usable, specialized facility functional areas and serviceable infrastructure support are essential to preserve, store, catalog, maintain, exhibit and manufacture digital records of special collections and historical records; Repair and restore major building systems and components that include structural, mechanical, plumbing, electrical, fire protection, communications, physical security and force protection. Perform building demolition of failed structural systems, installed equipment and utility components and systems. Remove Asbestos Containing Material (ACM) to include floor tiles and fire rated doors. Repair structural and non-structural floors, walls, doorways, egress routes, accessibility and stairs. Repair building superstructure, masonry and concrete structural floor systems. Conduct seismic remediation and structural upgrades/repairs of the building including footing, floor slab, and structural framing replacement. Repair electric service main and primary equipment, electrical primary underground duct banks and conductors, manholes, non-load break primary taps, entrance switchgear with primary transformer, stacked step-down transformers and the main electrical service entrance distribution panels. A backup electric generator will be placed for essential mission functions. Repair primary utility lines and piping for potable water, non-potable water, sanitary waste-water lines and vent piping, storm-water roof drains, natural gas and steam lines. Restore lines and chases for information technology system backbone. Repair and restore the roof, integrated gutter and internal downpipe drain system. Repair exterior building mortar joints, railings, door and window weather seals, damaged granite surfaces. Responses to this Sources Sought will be used by the Government for market analysis only, as an aid in its making of the appropriate acquisition decision(s); such as, use of a small business set-aside or full and open competition. This project is planned for advertisement in February 2021 and award on or about 10 May 2021.� If qualified firms do not respond to this Sources Sought Notice, the project may be acquired under full and open competition. Contract duration is estimated at approximately 730 calendar days. �The North American Industry Classification System (NAICS) code is 236220 for Commercial & Institutional Facilities. � All interested businesses should notify this office in writing by e-mail and provide a response to the questions below: Prior Construction/Renovation Performance � Submit a brief description of two (2) past performed projects, completed in the last seven (7) years (turned over to the customer), for a scope as follows (similar archives storage facility, academic building, administrative building, museum, memorial building, or other buildings with similar usage/occupancy): the Construction/Renovation of a 44,000 square foot structure that consists of unreinforced multi-wythe brick and stone bearing walls supporting steel beam and structural flat clay tile arch construction, with steel roof trusses-. The facility requires structural, HVAC, fire suppression, architectural, and electrical upgrades and/or replacement. Please state whether the company is a certified Small Business (SB), such as an 8(a) SB, HUBZone SB, Service Disabled Veteran-Owned SB (SDVOSB), or Women-Owned/Economically Disadvantaged Women-Owned SB (WOSB/EDWOSB), for NAICS Code 236220. Provide CAGE Code and DUNS Number. The interested contractor must indicate their capability of obtaining performance and payment bonds for a project in the dollar amount (price or range) listed above (indicate contract bonding capability and socio-economic status, e.g., SB, 8(a), HUBZone SB, SDVOSB, or WOSB/EDWOSB). All interested businesses should submit their responses by e-mail to the following: Nicole Fauntleroy, Contract Specialist E-MAIL: Nicole.C.Fauntleroy@usace.army.mil This is NOT a commitment on the part of the Government to award a contract as a result of this notice or to pay for any information received. This synopsis neither constitutes a Request for Proposal or Invitation for Bid, nor does it restrict the Government to an ultimate acquisition approach. This Sources Sought Synopsis should not be construed as a commitment by the Government for any purpose. The Government does not intend to rank submittals or provide any reply to interested firms. Submittals will be used for market survey information only. Place of Performance United States Military Academy at West Point, New York.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/6805f5bc468044668a2f360566d89c41/view)
 
Record
SN05876045-F 20201218/201216230151 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.