SOLICITATION NOTICE
Z -- Repair HVAC Dormitory Building 2405 and 2406 at Joint Base Charleston -Weapons Station, Goose Creek, South Carolina
- Notice Date
- 11/3/2020 11:42:35 AM
- Notice Type
- Solicitation
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- FA4418 628 CONS PK JOINT BASE CHARLESTON SC 29404-5021 USA
- ZIP Code
- 29404-5021
- Solicitation Number
- FA441820R0016
- Response Due
- 11/19/2020 12:00:00 PM
- Archive Date
- 12/04/2020
- Point of Contact
- Byron Faison, Phone: 8439635167, Robert R. Melton, Phone: 8439635173
- E-Mail Address
-
byron.faison@us.af.mil, robert.melton.6@us.af.mil
(byron.faison@us.af.mil, robert.melton.6@us.af.mil)
- Small Business Set-Aside
- SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Description
- **Please see Amendment 2 for current changes.� Attachment 7,8, and 9 have been attached.� Proposal Due date is now 19 November 2020 at 03:00 PM EST.**� **THE SOLICITATION NUMBER HAS CHANGED FROM FA4418-20-R-0016 TO FA4418-21-R-0002 due to the fiscal year changing from FY20 to FY21** Repair HVAC Dormitory�B2405/2406 - The work includes exterior wall repairs and modifications, complete removal and replacement of all exterior sealant joints including all liquid applied sealants, backer rods and silicone tape system on exterior walls at building expansion joints. Metal roof repairs and modifications. Roof gable louvers will be removed to provide access for removal of existing mechanical equipment and installation of new mechanical equipment. After the new mechanical equipment have been placed in the mechanical attic space a new louver with insulated closure panel will be installed. New backer rod and sealant will be installed around the perimeter of new louvers to provide a sealed condition. Perform an asbestos/lead survey before working. In the attic of each wing, replace the existing variable air volume air handling unit and dedicated outdoor air handling unit with a single new variable air volume air handling unit and an inline supply fan. Replace the existing energy recovery module (ERM), exhaust fan (EF), and filter modules. Replace a portion of the chilled water piping and ductwork such that the new equipment can be installed. Test the existing fire dampers and replace any fire dampers that are found to be faulty. Existing hip and ridge beams are to be supported by temporary screw jack shoring. Existing HSS columns and anchor bolts to be removed. Existing base plate of columns to be removed, and new base plate w/ alternate bolt pattern to be installed on existing columns. After equipment is removed and replaced, columns shall be reinstalled w/ epoxy anchors into existing concrete.�
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/0b34e0e0afa54f29907f22ed5131e9f2/view)
- Place of Performance
- Address: Goose Creek, SC 29445, USA
- Zip Code: 29445
- Country: USA
- Zip Code: 29445
- Record
- SN05844783-F 20201105/201103230141 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |