SOURCES SOUGHT
W -- Mobile CT Lease
- Notice Date
- 10/30/2020 2:03:17 PM
- Notice Type
- Sources Sought
- NAICS
- 621512
— Diagnostic Imaging Centers
- Contracting Office
- 258-NETWORK CNTRCT OFF 22G (36C258) MESA AZ 85212 USA
- ZIP Code
- 85212
- Solicitation Number
- 36C25821Q0016
- Response Due
- 11/6/2020 11:30:00 AM
- Archive Date
- 12/06/2020
- Point of Contact
- Nick W Price, Contracting Specialist, Phone: 480-466-7921, Fax: None
- E-Mail Address
-
Nicholas.Price@va.gov
(Nicholas.Price@va.gov)
- Awardee
- null
- Description
- The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 22 (NCO 22) is conducting a market survey and is seeking potential sources fora Autotransfusion Machine. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. Responses shall be submitted to Nick W Price at Nicholas.Price@va.gov by 11/6/2020 12:30 MST SUBJECT RFI 36C25821Q0016 This notice is intended strictly for market research. The purpose of this Sources Sought Notice is to determine interest and capability of potential qualified sources of supply and determine the socioeconomic size classification of the supplier and manufacturer of the end item. Interested companies shall provide, at a minimum, the following information with their response; Company Name and Address: Point of Contact (POC) Name: Email Address: Phone Number: DUNS Number: The anticipated North American Industry Classification System (NAICS) code: 621512 Diagnostic imaging centers Mark if your firm is eligible for participation in one of the following small business programs. If so, please indicate the program: [ ] yes [ ] no - Small Business (SB) [ ] yes [ ] no - HUBZone [ ] yes [ ] no - Small Business 8(a) [ ] yes [ ] no - Small Disadvantaged Business (SDB) [ ] yes [ ] no - Women-Owned (WO) Small Business [ ] yes [ ] no - Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no - Veteran Owned Small Business (VOSB) [ ] yes [ ] no - Large Business [ ] yes [ ] no - Other (please specify) Salient Characteristics for leasing the 16 Slice CT scanner Power injector Brand name or equal to Bayer (6 months lease) Medrad Stellant 16-slice CT scanner Medrad Stellant CT injector Floor pedestal with locking wheels Dual syringe: Simultaneous injection of contrast and saline Flow rate: 0.1-10mL/s in 0.1mL/s increments Volume: 200 mL capacity in 1-mL increments Programmable pressure limits Scan reminders: 5 minutes in 1-second increments Pause: 15 minutes in 1-second increments Hold: 20 minutes Phases: 6 Protocols: 250 The equipment shall include a phantom for daily QA tests The equipment shall have a Windows 10 or Linux operating system The equipment shall use ethernet to connect to the VA network Compatible with the Facility s 480 volt, 3 phase, 200 amp power. Training requirements for Lease for both the CT scanner and Power injector The Vendor shall provide applications training for both the CT scanner and Power injector Training for 12 CT technicians need to be trained. Leasing Installation and Start up requirements (6 months) Vendor shall connect the equipment to power, configure the system and verify image quality and that the system is operating per OEM specifications. The Vendor must to hook up the system to existing utilities 480 volt, 3 phase, 200 amp power, start-up the system, and configure the system for usage. Lease Maintenance and Emergency coverage (6 months) The lease must cover all corrective and preventive maintenance and perform ongoing demand repair and maintenance of the same between the hours of 8 am to 5 pm Monday through Friday, The lease must have an 8-hour response time if the equipment is hard down or emergency repair is needed and not capable of performing clinical use.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/e16dfaef219440908188e0e4056da255/view)
- Place of Performance
- Address: Department of Veteran Affairs Phoenix VA Health Care System 650 East Indian School Rd, Phoenix 85012
- Zip Code: 85012
- Zip Code: 85012
- Record
- SN05842663-F 20201101/201030230146 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |