SPECIAL NOTICE
99 -- Request for Information MCV Shelter Doors and Docking Station
- Notice Date
- 10/22/2020 10:12:34 AM
- Notice Type
- Special Notice
- Contracting Office
- U S ARMY DEPOT TOBYHANNA TOBYHANNA PA 18466-5079 USA
- ZIP Code
- 18466-5079
- Response Due
- 11/2/2020 12:30:00 PM
- Archive Date
- 11/17/2020
- Point of Contact
- Kristi-Jo M. Noel, Phone: 5706159051
- E-Mail Address
-
kristi-jo.m.noel.civ@mail.mil
(kristi-jo.m.noel.civ@mail.mil)
- Description
- THIS IS A REQUEST FOR INFORMATION (RFI) ONLY � This RFI is issued solely for information and planning purposes � it does not constitute a Request for Proposal (RFP) or a promise to issue an RFP in the future.� Responses will be treated as information only and will not be used as a proposal. Solicitations are not available at this time.� Requests for a solicitation will not receive a response.� This notice does not constitute a commitment by the United States Government to contract for any supply or service whatsoever.� All information submitted in response to this announcement is voluntary; the United States Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the United States Government. All information received in response to this RFI that is marked proprietary will be handled accordingly. Responses to this RFI that indicate that the information therein is proprietary, or represents confidential business information, will be received and held in confidence. Not responding to this RFI does not preclude participation in any future RFP, if any is issued.� If a solicitation is released, it will be synopsized on https://beta.SAM.gov �website.� It is the responsibility of the potential offerors to monitor this site for additional information pertaining to this requirement. The Government reserves the right to follow up on a one-on-one basis with RFI respondents to gain additional information or clarity about information submitted. GENERAL REQUIREMENTS: The Army Contracting Command � Aberdeen Proving Grounds (ACC-APG), Tobyhanna Division, is conducting this RFI in order to identify potential vendors capable of providing the following items: Mission Communication Van (MCV) Shelter Door Construction:� 304 Stainless steel Clear opening:� 40.00 inches (� 1.00 inch) Wide by 76.5 inches High (� 1.00 inch). Features:� 1� wide stainless steel tube knife edge Function:� Manual Testing:� MIL-STD-188-125-1 for High-Altitude Electromagnetic Pulse (HEMP) shielding effectiveness MCV Escape Hatch Door Construction:� 304 Stainless steel Clear opening:� 28.00 inches (+ 0.50 -0.00inch) wide by 28.00 inches high (+0.50 -0.00 inch) Features:� 1� wide stainless steel tube knife edge Function:� Manual Testing:� MIL-STD-188-125-1 for HEMP shielding effectiveness Vestibule Double Air-Seal Door Clear opening:� 40.00 inches (� 1.00 inch) Wide by 76.5 inches High (� 1.00 inch). Features:� Integrated fiber-optic door switch system which can operate without the use of electrical filters. �2x 1� dia. Waveguide Beyond Cutoff (WBC) tubes integrated into door frame.� Stainless steel construction. Function:� Electronically controlled, pneumatically actuated air seals.� Redundant double air seals consisting of tin plated copper wire braid surrounding Ethylene Propylene Diene Monomer (EPDM) rubber tubes.� Each seal shall be capable of meeting MIL-STD-188-125-1 shielding requirements independently, and be capable of being individually deflated for replacement. Testing:� MIL-STD-188-125-1 for HEMP shielding effectiveness HEMP Docking Station Description:� Flexible docking station capable of linking HEMP/Chemical, Biological, Radio, Nuclear (CBRN) hardened shelters to allow for a continuous HEMP volume between multiple mobile hardened shelters.� Must allow for movement of assembly 1.25"" in X, Y, and Z axis.� Must be capable of interfacing with Gaven Industries weld-on mounting ring (Part No. 07184-10) while meeting all of the HEMP hardening requirements of MIL-STD-188-125-2.� Construction:� 304 Stainless steel Clear opening:� 66.00 inches (� 1.00 inch) Wide by 86.5 inches High (� 1.00 inch). Exterior Dimensions:� Approximately 78"" Wide X 100"" Tall X 36"" Deep Testing:� MIL-STD-188-125-1 for HEMP shielding effectiveness Questions regarding this RFI can be e-mailed to: Kristi-Jo Noel Contract Specialist kristi-jo.m.noel.civ@mail.mil Complete written responses to this RFI addressing the General Requirement capabilities are to be submitted to the above referenced e-mail address.� Respondents should include the following business information with the RFI response: Company name; Company address; Point of Contact; Telephone Number; E-mail address; Company Cage Code; Primary NAICS; Business Size; Current Registration in SAM; �Web page address. No feedback or evaluations will be provided to companies regarding their submissions.�
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/e50487d3af4c4231baa72a265073b2e0/view)
- Record
- SN05835456-F 20201024/201022230137 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |