SPECIAL NOTICE
99 -- West End Protected Area Reduction (WEPAR) Perimeter Intrusion Detection and Assessment System (PIDAS) at Y-12 National Security Complex
- Notice Date
- 10/6/2020 7:53:10 AM
- Notice Type
- Special Notice
- NAICS
- 237990
— Other Heavy and Civil Engineering Construction
- Contracting Office
- NTESS, LLC - DOE CONTRACTOR Albuquerque NM 87185 USA
- ZIP Code
- 87185
- Solicitation Number
- SNL_SPEC_10-6-2020
- Response Due
- 10/13/2020 10:59:00 PM
- Archive Date
- 10/28/2020
- Point of Contact
- Devin DeMenno, Phone: 5052490309
- E-Mail Address
-
ddemenn@sandia.gov
(ddemenn@sandia.gov)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- NTESS has completed the design and is seeking an Offeror who can safely and effectively perform the construction of the project summarized below. The West End Protected Area Reduction (WEPAR) project, involves installing a new Perimeter Intrusion Detection and Assessment System (PIDAS) along H Road and North First Street at Y-12 in Oak Ridge, TN. The H-Road PIDAS project involves the construction of a new PIDAS that ties-into security systems. The project shall consist of the following key activities: Site Prep Phase Demolition of existing zones Grading for the PIDAS and patrol road Plug removal Retaining wall construction Multi-use security trench preparation Patrol road and N. First Street roadway construction PIDAS Installation Vehicle barrier installation Existing communications reroute installation Electrical infrastructure installation Mandatory Criteria: Interested Offerors shall respond to each of the following mandatory requirements by stating either �yes, the supplier meets this requirement"" or �no, the supplier does not meet this requirement� and provide verification documentation as requested in the requirements to Devin DeMenno at ddemenn@sandia.gov no later than the posting close date. Failure to meet any of the requirements, or to provide the requested documentation proving the Offeror meets the requirement will result in the Offeror not being invited to the RFQ. Mandatory Requirement 1: The Offeror and Offeror's personnel shall be capable of securely storing and maintaining information up to the classification of Unclassified Nuclear Information (UCNI) in accordance with DOE Order 471.1B. The Offeror must indicate it has reviewed the DOE order and is capable of meeting the requirements. Mandatory Requirement 2: All Offeror personnel assigned to the project shall be United States citizens. The Offeror must indicate it is capable of meeting this requirement. Mandatory Requirement 3: The Offeror shall provide information on two single civil infrastructure construction projects, where they were the prime contractor, with a total construction amount of at least $12,000,000 each, that were completed no more than 6 years prior to the date of this solicitation. Provide the following information for each project to verify the Offeror meets the mandatory requirement: Full Project Title Description of the Statement of Work Project Customer Project Customer Contact Name, Phone Number and Email Address Period of Performance Project Amount Mandatory Requirement 4: The Offeror will be required to provide performance and payment bonds for the entire project bid amount as a notice to proceed item. The Offeror shall have a single project bonding capacity of at least $24,000,000. The Offeror shall provide a letter from its surety stating the Offeror�s bonding capacity. Additionally, the interested Offeror shall not have had a surety complete any work on behalf of the Offeror in the past five years. The Offeror shall also provide a letter from its surety attesting to this fact. Mandatory Requirement 5: All safety metrics below will be required to be met by the Offeror and documentation shall be submitted to confirm the Offeror's safety metrics. Occupational Safety & Health Administration (OSHA) Total Recordable Case Rate (TRCR) shall average 4.0 or below for the past three calendar years. OSHA Days-Away Restricted Time (DART) shall average 2.1 or below for the past three calendar years. Experience Modification Rate (EMR) from the insurance provider of the Offeror shall average 0.9 or less for the past three calendar years. Zero fatalities in the past ten years. Mandatory Requirement 6:� The Offeror must, by proposal due date, have a documented Worker Safety and Health Program�in full compliance with subparts A, B, & C of�10 CFR 851: Worker Safety and Health Program.�The program must be applicable to the construction scope of work as defined by the regulation and cover all expected hazards pertinent to the scope of work described in the forthcoming RFQ. The Offeror must indicate it has reviewed the regulation and is capable of providing a compliant Worker Safety and Health Program by the proposal due date. Mandatory Requirement 7: The Offeror shall possess a Tennessee Municipal and Utility Construction license (MU), a commercial (BC-B or BC) is considered an acceptable license as well or out of state equivalent. Offerors are exempt if the Offeror's state or local municipality does not have a construction contracting licensing program. The Offeror shall either provide their license or indicate they are exempt from this requirement. Mandatory Requirement 8:�The Supplier shall have experience controlling or mitigating environmental contamination of hazardous substances, specifically radiation and/or heavy metals. The Supplier shall provide information on one project where the Supplier provided construction services at a site designated as Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or a site with environmental contamination of radioactive or heavy metal hazardous substances, and the Supplier had to control and/or mitigate the contamination, and that was completed no more than six years prior to the date of this solicitation. Provide the following information for each project to verify the Offeror meets the mandatory requirement: Full Project Title Description of the Statement of Work Project Customer Project Customer Contact Name, Phone Number and Email Address Period of Performance List what hazards the Supplier had to mitigate or control Detail what mitigation or control measures the Supplier had to take for environmental contamination of hazardous substances
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/3045503c70074adabc261aebcc297d34/view)
- Place of Performance
- Address: Oak Ridge, TN 37830, USA
- Zip Code: 37830
- Country: USA
- Zip Code: 37830
- Record
- SN05819512-F 20201008/201006230137 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)