Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF OCTOBER 04, 2020 SAM #6884
SOURCES SOUGHT

Z -- RFI 36C24221Q0046: Replace Skylight

Notice Date
10/2/2020 12:20:29 PM
 
Notice Type
Sources Sought
 
NAICS
238150 — Glass and Glazing Contractors
 
Contracting Office
242-NETWORK CONTRACT OFFICE 02 (36C242) ALBANY NY 12208 USA
 
ZIP Code
12208
 
Solicitation Number
36C24221Q0046
 
Response Due
10/9/2020 1:00:00 PM
 
Archive Date
12/08/2020
 
Point of Contact
Delfo.Saco-mizhquiri@va.gov, Delfo.Saco-mizhquiri, Phone: (718) 526-1000 ext 7524
 
E-Mail Address
delfo.saco-mizhquiri@va.gov
(delfo.saco-mizhquiri@va.gov)
 
Awardee
null
 
Description
Page 3 of 3 DISCLAIMER This Request for Information (RFI) is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. Responses to this notice must be submitted in writing via email and must be received not later than Friday, October 9, 2020, 4:00pm EST. No telephone inquiries will be accepted. The purpose of this notice is to gain knowledge of potential qualified sources and their size classification/socioeconomic status (service-disabled veteran owned small business, veteran owned small business, HUB Zone, 8(a), small business or large business). Responses to this notice will be used by the Government to make appropriate acquisition decisions. Responses to this notice should include company/individual name, a service capability statement, examples of similar facilities for which you have provided services to, proof of applicable certification. DUNS number, address, point of contact and social-economic category (ex: SBVOSB, VOSB, 8(a), HUBZone, WOSB, EDWOSB, Small Business). If your firm is a Service-Disabled Veteran Owned or Veteran Owned Small Business, you must be CERTIFIED in VetBiz (see internet site: http://vip.vetbiz.gov). Contractor must be registered in System for Award Management (SAM). Responses to this notice must be submitted in writing, and received not later than Friday, October 9, 2020, 4:00pm EST. All interested parties must respond to any related solicitation announcement separately from the responses to this announcement. Email: Delfo.Saco-mizhquiri@va.gov. No telephone inquiries will be accepted. WORK DESCRIPTION Title: Replace Skylight This skylight is in the pavilion of Building 200 North. Exterior glass has shattered, and interior glass panel is intact. It is approximately 30 feet to the highest point on a pitched roof. It is in the middle of a high-volume hallway of the hospital. This work will need to be performed on a Saturday or Sunday due to the volume of patients Monday through Friday. Contractor will provide all supervision labor, material, tools, equipment, supplies and all logistical needs to complete the project in a safe and professional manner. All contractors' personnel will have all required PPE as per task at hand requirements and Safety training certifications required: OSHA 30 for the foreman or competent person, all other personnel will be required OSHA 10, as well as any other certifications as required. Contractor will provide safety barrier beneath skylight to contain all debris and to keep people back a safe distance. Tarps must be used to contain all dust and debris inside the safety barrier. Air ducts in the immediate area will need to be sealed while work is being performed. All walkway obstruction will be removed, and the site will be broom swept by the end of the day. No equipment shall be left in building overnight. Work must be performed in accordance with all Federal, State and local codes. If work is not completed in one day the Facility will require it to be watertight with a hard material to withstand 50 mph winds by close of business. Contractor is responsible for any damage done by his personnel or equipment. This work requires preparation of area, removal of existing skylight and removal from site.as well. The Skylight hole shall be cleaned and prepared for new skylight. Any Damage to the framing, will need to be reported immediately to the Facility Representative. A custom 1 1/8"" Reflective safety glass Thermopane unit with ΒΌ"" tempered over 3/8"" laminated safety glass. The size is 64"" X 72"" all dimensions to be field verified. This will be installed as per manufactures specification and to completion. END OF WORK DESCRIPTION DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/50c9934348a44b6f94437e7951eddaa8/view)
 
Place of Performance
Address: Department of Veterans Affairs Northport VA Medical Center 70 Middleville Rd., Northport, NY 11768, USA
Zip Code: 11768
Country: USA
 
Record
SN05818140-F 20201004/201002230147 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.