Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF OCTOBER 02, 2020 SAM #6882
SOLICITATION NOTICE

65 -- Amendment 1 is issued to CANCEL SOLICITATION 36C25920Q0807 Draeger Perseus A500 Anesthesia Machines

Notice Date
9/30/2020 9:31:05 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
NETWORK CONTRACT OFFICE 19 (36C259) Greenwood Village CO 80111 USA
 
ZIP Code
80111
 
Solicitation Number
36C25920Q0807
 
Response Due
9/30/2020 4:00:00 PM
 
Archive Date
10/30/2020
 
Point of Contact
Loretta Schmidt, Contract Specialist, Phone: 303-349-6851
 
E-Mail Address
Loretta.Schmidt@va.gov
(Loretta.Schmidt@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
Request for Quote (RFQ) #: 36C25920Q0807 Draeger Perseus A500 Anesthesia Machines This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. The Government reserves the right to make no award from this solicitation. * The deadline for all questions is 12:00pm MT, Friday, September 25, 2020. All questions must be submitted in writing no later than the question cut-off date marked above. All questions will be answered officially through an amendment to the solicitation. ** Quotes are to be provided to Loretta.Schmidt@va.gov no later than 12:00pm MT, Monday, September 28, 2020. Quotes shall not be hand carried. Faxed quotes shall not be accepted. Emailed quotes are the only method of submitted quotes (4MB email limit). The Government reserves the right to make award solely on initial Quotes received. Offerors bear the burden of ensuring that all portions of the offer (and any authorized amendments) reach the designated office before the deadline specified in the solicitation. This RFQ shall be completed in its entirety, and signed and dated, failure shall not be considered for award. This is a Request for Quote (RFQ) and the solicitation number is RFQ# 36C25920Q0807. The government anticipates awarding a firm-fixed price contract resulting from this solicitation. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2020-08 effective August 13, 2020. The North American Industrial Classification System (NAICS) code for this procurement is 339113 with a small business size standard of 750 employees. This solicitation is a 100% set-aside for Service-Disabled Veteran-Owned Small Business (SDVOSB). List of Line Items; ITEM # DESCRIPTION OF SUPPLIES/SERVICES QTY UNIT UNIT PRICE AMOUNT 0001 DRAEGER PERSEUS A500 ANESTHESIA MACHINE PERSEUS A500 -SUITABLE FOR ADULT, PEDIATRIC AND NEONATAL PATIENTS -SUITABLE FOR LOW-AND MINIMAL FLOW INHALATION ANESTHESIA BASIC UNIT -PRECISE, ELECTRICALLY-DRIVEN TURBO VENT 2 VENTILATOR: NO DRIVING GAS REQUIRED -HEATED,COMPACT BREATHING SYSTEM -TIME-BASED, FULLY AUTOMATIC STARTUP AND INCLUDING A SYSTEM TEST -BATTERY FOR UP TO 150 MINUTES BACK-UP POWER -INTEGRATED RFID TECHNOLOGY MONITORS ADEQUATE USE OF SENDORS AND CONSUMABLES -LCD STATUS DISPLAY FOR GAS AND POWER SUPPLIES AS WELL AS AIRWAY PRESSURE GAS MONITORING -INTEGRATED GAS MONITORING; INSPIRATORY AND EXPIRATORY GAS CONCENTRATIONS; AUTOMATIC IDENTIFICATION OF TWO ANESTHETIC AGENTS; AGE-ADJUSTED MAC VALUE -CONSUMPTION-FREE OXYGEN MONITORING -MEASUREMENT OF GAS CONSUMPTION 15.3"" COLOR TOUCHSCREEN DISPLAY -STANDARDIZED DRAGER USER INTERFACE, CONFIGURABLE -DISPLAY OF FRESH-GAS EFFICIENCY (MINIMAL FLOW) -DISPLAY OF THREE WAVEFORMS,PARAMETERS AND MINI TRENDS SIMULTANEOUSLY ERONOMICS -INTEGRATED WORKPLACE ILLUMINATION 6 EA 0002 ***MAIN CONFIGURATION*** BASIC UNIT TROLLEY BASED BASIC UNIT PERSEUS A500 EQUIPPED WITH: -4 INTEGRATED COUNTRY-SPECIFIC POWER OUTLETS -ISOLATION TRANSFORMER -MAIN SWITCH FOR ALL OUTLETS -CIRSUIT BREAKERS FOR EACH POWER OUTLET *SW-VERSION PERSEUS 1.13 6 EA 0003 ELECTRONIC GAS MIXER E1.L3-GAS MIXER, ADV.CYL.SUPP. 0.01.0.07 6 EA 0004 OPTION VAPOR COMMUNICATION *DRAGER AUTO EXCLUSION, 2 VAP. OPT. VAPOR COMMUNICATION(2 VAPS) HW & SW FUNCTIONALITY FOR ILLUMINATING VAPORIZER SETTINGS AND FILLING LEVEL INDICATOR - MONITORING OF VAPORIZER SETTINGS AND FILLING LEVELS. FUNCTION ONLY AVAILABLE WITH (D-)VAPOR 3000. 6 EA 0005 QUICK REFERENCE GUIDE EN US 6 EA 0006 ***GAS SUPPLY*** FOR HANGING GAS CYLINDER CYLINDER HOLDER PIN INDEX 6 EA 0007 PRESS RED. O2, FOR SMALL CYL. PRESSURE REDUCER O2, PIN INDEX *GAS CONNECTIONS DISS O2 WITH DRAEGER PRESSURE REDUCER 6 EA 0008 ***AUXILARY POWER OUTLET*** *COUNTRY-SPEC. POWER OUTLET ADDITIONAL POWER OUTLET STRIP POWER SOCKER STRIP FOR CONNECTION UP TO 4 ADDITIONAL ELECTRICAL DEVICES 6 EA 0009 MOUNTING POLE RIGHT 6 EA 0010 ***VENTILATOR & DISPLAY*** SW OPTION APRV VENTILATION MODE WITH 2 CPAP LEVELSUPPER CPAP LEVEL IS REDUCED PERIODICALLY FOR A SHORT TIME TO THE LOWER CPAP LEVEL PATIENT BREATHES SPONTANEOUSLY ON UPPER CPAP LEVEL- SPONTANEOUS COMPLEMENTED BY PERIODICAL PRESSURE RELEASES TO INCREASE CO2 WASHOUT 6 EA 0011 SW OPTION PRESSURE SUPPORT THE VENTILATOR IS ABLE TO RECOGNIZE AND SUPPORT THE PATIENT'S BREATHING EFFORTS THE PRESSURE SUPPORT LEVEL AND THE TRIGGER SENSITIVITY CAN BE SET ACCORDING TO THE PATIENTS NEEDS - A MINIMUM RESPIRATORY RATE CAN BE SET; MANDATORY BREATHS WILL THEN BE DELIVERED WHEN BREATHING EFFORTS CEASE OR BECOME TOO INFREQUEST-DURING VOLUME-OR PRESSURE - CONTROLLED BREATHS CAN BE TRIGGERED BETWEEN MANDATORY BREATHS-CPAP (DEVICE DELIVERS A CONSTANT PEEP) IS ALSO POSSIBLE DURING MAN/SPON VENTILATION 6 EA SW OPTION PRESSURE SUPPORT THE VENTILATOR IS ABLE TO RECOGNIZE AND SUPPORT THE PATIENT'S BREATHING EFFORTS THE PRESSURE SUPPORT LEVEL AND THE TRIGGER SENSITIVITY CAN BE SET ACCORDING TO THE PATIENTS NEEDS - A MINIMUM RESPIRATORY RATE CAN BE SET; MANDATORY BREATHS WILL THEN BE DELIVERED WHEN BREATHING EFFORTS CEASE OR BECOME TOO INFREQUEST-DURING VOLUME-OR PRESSURE - CONTROLLED BREATHS CAN BE TRIGGERED BETWEEN MANDATORY BREATHS-CPAP (DEVICE DELIVERS A CONSTANT PEEP) IS ALSO POSSIBLE DURING MAN/SPON VENTILATION 0012 SW OPTION BREATHING SOUND EM. CREATES AN AUDIO SIGNAL INDICATING CHANGES IN THE GAS FLOW. *SW OPT. LOW FLOW WIZARD 6 EA 0013 DRAGER FLEXIBLE BREATHING BAG ARM FLEXIBLE ARM FOR CONNECTING THE MANUAL BREATHING BAG W/O EXTERNAL FRESH-GAS OUTLET 6 EA 0014 ***REQUIRED ACCESSORIES*** CONTROL VALVE NPT INF. ID FLOW SENSOR, 5 PCS. ADAPTER FOR CLIC ABSORBER ***ENDOTRACHEAL SUCTION*** 6 EA 0015 ENDOTRACH SUCTION DISS, VAC 6 EA 0016 MOUNTING KIT VAC SUCTION 6 EA 0017 SUCTION ACC (HOOP, TIP HOLDER) 6 EA 0018 ***HARDWARE COMPONENTS*** MOUNTING POLE RIGHT MOUNTING POLE FOR MOUNTING ADDITIONAL EQUIPMENT TO THE REAR OF THE WORKSTATION DIAMETER 38 MM 6 EA 0019 PRESSURE GAUGE 6 EA 0020 DRAWER MODULE LARGE 6 EA 0021 BOX WITH WRITING TRAY 6 EA 0022 Adapter-DISS M/QC-O2-Ohmeda Adapter O2, DISS male/Ohmeda-O2 coupling 6 EA 0023 Adapter-DISS M/QC-N2O-Ohmeda Adapter N2O, DISS male/Ohmeda-N2O coupling 6 EA 0024 Adapter-DISS M/QC-AIR-Ohmeda Adapter AIR, DISS male/Ohmeda-AIR coupling 6 EA 0025 Adapter-DISS M/QC-VAC-Ohmeda Adapter VAC, DISS male/Ohmeda-VAC coupling 6 EA 0026 Adapter-DISS M/QC-EVAC-Ohmeda Adapter EVAC, DISSmale/Ohmeda-EVAC coupling 6 EA 0027 O2 CS HOSE 10 FT DISSN/DISSN 6 EA 0028 N2OCS HOSE 10 FT DISSN/DISSN 6 EA 0029 AIR CS hose 10ft DISSN/DISSN 6 EA 0030 VAC CS hose 10ft DISSN/DISSN 6 EA 0031 EVAC CS hose DISSN/DISSN 10ft 6 EA 0032 Adapter-DISS M/QC-VAC-Ohmeda Adapter VAC, DISS male/Ohmeda-VAC coupling 6 EA 0033 VAC CS hose 10ft DISSN/DISSN 6 EA 0034 Infinity ID WaterLock2Water trap Infinityr ID WaterLockr 2 12 EA 0035 Draeger CLIC absorber 800+The disposable CLIC absorber 800+ for Dr?ger anesthesia machines is attached to the existing absorber holder by means of an adapter. A quick, clean,easy-to-use disposable solution. The CLIC absorber 800+ is filled with D r?gersorbr 800 Plus. 30 EA 0036 Draeger CASTrGARD, small (Set of 4) Wheel guard for rollover protection of hoses and cables, for all 4 wheels. 4 EA 0037 VAPOR 3000 VAPOR 3000 ANESTHETIC VAPORIZER FOR VOLATILE ANESTHETIC AGENTS -- for use in the fresh-gas circuit of anesthesia workstations - ""T"" setting for intrahospital transport in any position while filled - 300 mL liquid filling capacity When used on anesthesia workstations with ""Vapor View"": illumination of vaporizer settings and fill level sight glass **SPECIF. NATIONAL PROPERT** TARGET COUNTRY USA 6 EA 0038 Vapor 3000 Sevoflurane Filling system Draeger Fill Dr?ger standard 6 EA 0039 D-Vapor 3000 D-Vapor 3000 anesthetic vaporizer for the delivery of Desflurane - internal battery provides a maximum of 5 minutes back-up power during mains power failure - 300 mL liquid filling capacity - concentration range 2 to 18 Vol.% ""T"" setting for intrahospital transport in any position while filled When used on anesthesia workstations with ""Vapor View"": illumination of vaporizer settings and fill level sight glass **SPECIF NATIONAL PROPERT.** TARGET COUNTRY USA NEMA 5-15P / HOSPITAL GRADE 6 EA 0040 D-Vapor 3000 Front cap Draeger Country-specific power cable 6 EA 0041 IACS Monitoring with C500 IACS Monitoring with C500 **SPECIF NATIONAL PROPERT.** TARGET COUNTRY USA **MEDICAL COCKPIT** MONITORING WITH C500 **CARE UNIT** OR/Induction (Periop) **WORKSTATION MOUNTING** For an existing Draeger device Others 6 EA 0042 **Infinity Acute Care System** Monitoring with C500 Monitoring solution Infinity Acute Care System Monitored parameters: ECG, basic arrhythmia, respiration, pulse rate, temperature, non-invasive blood pressure, and invasive blood pressure INCLUDES: - Infinity M540 patient monitor - Infinity C500 Medical Cockpit (17"" widescreen color display with touchscreen functionality and rotary knob) - Infinity M500 docking station - P2500 power supply unit - SpO2 MCable - system cables - power cable Instructions for Use ** SpO2 Technology ** Nellcor OxiMax MCable SpO2 Pod Mounting 6 EA 0043 Draeger M500 Cable Hook Cable Holder, Mounts Below the M500 Docking Station 6 EA 0044 Draeger SW opt 12-Lead ECG Monitoring Software option 12-lead ECG - enables 12-lead ECG on the IACS(10 lead wires are required for the Infinity M540) 6 EA 0045 Draeger SW option Arrhythmia II Software option Arrhythmia II - for adult and pediatric patients supplements basic arrhythmia monitoring with: accelerated idioventricular rhythm, ventricular run, supra-ventricular tachycardia, couplet, bigeminy, tachycardia, bradycardia, and pause 6 EA 0046 Draeger SW option Multi IBP Software option Multi-IBP - to monitor more than 2 invasive blood pressures on the IACS option for use with patient parameter module Infinity MPod Quad Hemo 6 EA 0047 Draeger SW option M540 Wireless ** IFUs ** * Single set of IFU/s * Supplied per order. * IFUs on a DVD ordered. ADDITIONAL MANUAL NOT ORDERED INCLUDED AT NO-CHARGE EXPANDED MONITORING PROMOTION SW OPT 12-LEAD ECG Monitoring SW opt Arrhythmia II SW opt Multi IBP SW opt M540 Wireless 6 EA 0048 IACS Device Connectivity IACS Device Connectivity **Specif.national properties** Target country USA 120 V 6 EA 0049 ** Device interface options ** Draeger Perseus A500 Cockpit to Dim cable 4.3M(14') New IACS with this order Connect the Dots Promo 6 EA 0050 SW OPT, UPG & IFU - IACS/M540 SW OPT, UPG & IFU - IACS/M540 **Specif.national properties** Target country USA *IACS* SW OPTIONS 1 EA 0051 **IACS S/W Options** View Editor 1 EA 0052 CK power supply for drawers XL 6 EA 0053 Swivel arm 400x400mm, M540 6 EA 0054 SPO2 NELLCOR CABLE 3M F MCABLE 6 EA 0055 SPO2 Nellcor sensor DS100A Adt Reusable SpO2 adult sensor. For finger or toe application. Patient weight > 40 kg. 6 EA 0056 ECG 3-Lead single-pin AHA, 1m ECG cable, 3-Lead, single-pin connector, reusable, AHA (IEC2), 1 m 6 EA 0057 ECG 5-Lead single-p AHA, 1.5m ECG cable, 5-Lead, single-pin connector, reusable, AHA (IEC2), 1/1.5 m 3 EA 0058 ECG EXTENSION SINGLE-PIN, 2M 2m extension cable for 3-, 5-, 6-wire ECG Monolead or traditional grabber cables. 6 EA 0059 Draeger NBP extension hose, adult 3,7m NIBP connection tube, adult, 3.7 m - to connect NIBP cuffs adult/pediatric to Draeger Infinity patient monitoring systems - with user-friendly connector to prevent misconnection 6 EA 0060 Draeger INFINITY MCABLE DUAL HEMO Connection cable Infinity MCable - Dual Hemo - to be connected to Infinity M540 monitor - provides continuous monitoring of 2 invasive blood pressures 4 EA 0061 TRANSDUCER CABLE ABBOTT /MEDEX Transducer adapter cable for Abbott IBP transducers on Infinity MCable Dual Hemo or Infinity MPod Quad Hemo. 8 EA 0062 TEMP PROBE ADAPTER CABLE Adapter for temp. Probes with 1/4"" connector to be used with MultiMed 5/6 or NeoMed pod. 6 EA 0063 INFINITY R50-N RECORDER Recorder Infinity R50-N - two-channel recorder that provides documentation of stored events, alarms, waveforms, and trends - for connection anywhere on the Infinity network, independent of patient monitor location Includes: - mounting plate for wall mount - Infinity R50 recording paper, 10 rolls - installation instructions 6 EA 0064 POWER CORD, N.AMERICA, 5-15A 6 EA 0065 NETWORK CROSSOVER CBL, 2M Network crossover cable, 2 m Cable which allows: - connection of a laser printer to a standalone IDS - direct connection of a laser printer to the Ethernet port of the Infinity Delta/Kappa/DeltaXL monitors 6 EA 0066 Clinical Applicat.SuppAnesthesia .8hsegm. 5 EA 0067 3rd Party Hardware 1 EA 0068 Trade in Aysis 6 EA 0069 Shipping 1 EA GRAND TOTAL _____________ Description of Requirements for the items to be acquired: See description in (v), attached Statement of Work, and attached Brand Name Justification. Delivery and acceptance are to be F.O.B Destination (FAR 52.247-34) at the VA Montana Health Care System, 3687 Veterans Dr., Ft. Harrison, MT 59636. 52.212-1, Instructions to Offerors--Commercial ADDENDUM to FAR 52.212-1 INSTRUCTIONS TO OFFERORS COMMERCIAL Gray market items are Original Equipment Manufacturers (OEM) goods sold through unauthorized channels in direct competition with authorized distributors. This procurement is for new OEM medical supplies, medical equipment and/or services contracts for maintenance of medical equipment (i.e. replacement parts) for VA Medical Centers.  No remanufactures or gray market items will be acceptable. Offeror shall be an OEM, authorized dealer, authorized distributor or authorized reseller for the proposed medical supplies, medical equipment and/or services contracts for maintenance of medical equipment (i.e. replacement parts), verified by an authorization letter or other documents from the OEM, such that the OEM s warranty and service are provided and maintained by the OEM.  All software licensing, warranty and service associated with the medical supplies, medical equipment and/or services contracts for maintenance of medical equipment shall be in accordance with the OEM terms and conditions. The delivery of gray market items to the VA in the fulfillment of an order/award constitutes a breach of contract.  Accordingly, the VA reserves the right enforce any of its contractual remedies. This includes termination of the contract or, solely at the VA s election, allowing the Vendor to replace, at no cost to the Government, any remanufactured or gray market item(s) delivered to a VA medical facility upon discovery of such items. Any award made as a result of this solicitation will be made on an All or Nothing Basis. State if quoted items are available and priced through offerors existing Government-wide Acquisition Contract (GWAC), GSA Multiple Award Schedule (MAS) contract, or VA-wide Acquisition Contract. If the acquisition is set-aside for SDVOSBs/VOSBs, their socioeconomic status must be VIP verified and visible in the VA Vendor Information Pages (VIP): https://www.vip.vetbiz.gov/ at the time of quote submission AND award, or will be considered non-responsive, and will NOT be considered for award. Offerors are warned against contacting any VA personnel other than the Contracting Officer and Contract Specialist prior to placement of any award made resulting from this RFQ. If such contact occurs and found to be prejudicial to competing contactors, the offeror making such contact may be excluded from award considerations. All proprietary information shall be clearly and properly marked. If the Offeror submits annexes, documentation, attachments or the like, not specifically required by this solicitation, such will count against the Offeror s page limitations unless otherwise indicated in the specific volume instructions below. All information shall be confined to the appropriate file. The offeror shall confine submissions to essential matters, sufficient to define the quote and provide an adequate basis for evaluation. Offerors are responsible for including sufficient details, in a concise manner, to permit a complete and accurate evaluation of each quote. Submission of quote shall include the following volumes: (I) Price and (II) Proof of Meeting the Special Standards of Responsibility Volume I Price (utilizing format of paragraph (v) above) Price - The offeror shall complete the pricing schedule provided in Section (v) above: Price/Cost Schedule. Volume II Proof of Meeting the Special Standards of Responsibility The offeror must provide proof of being an authorized distributor of Draeger Perseus A500 anesthesia machines with the capability of performing all requirements as outlined in the Statement of Work and in this Combined Synopsis Solicitation. (End of Addendum to 52.212-1) 52.212-2, Evaluation--Commercial Items ADDENDUM to FAR 52.212-2 EVALUATION COMMERCIAL ITEMS: This is FAR Part 13 acquisition utilizing Lowest Price Technically Acceptable (LPTA) procedures. The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government considering price and special standards of responsibility. The following factors shall be used to evaluate offers: Price The Government will evaluate offers by adding all line item prices - the Total of All CLINS will be that sum. The Government may use various price analysis techniques and procedures to make a price reasonableness determination. Offers that do not meet the special standards of responsibility shall not be selected regardless of price. Special Standards of Responsibility The offeror must be an authorized distributor of the Draeger Perseus A500 anesthesia machines with the capability of performing all requirements as outlined in the Statement of Work and in this Combined Synopsis Solicitation. (b) Options. The Government will evaluate offers for award purposes by adding the total price for all options to the total price for the basic requirement. The Government may determine that an offer is unacceptable if the option prices are significantly unbalanced. Evaluation of options shall not obligate the Government to exercise the option(s). (c) A written notice of award or acceptance of an offer, mailed or otherwise furnished to the successful offeror within the time for acceptance specified in the offer, shall result in a binding contract without further action by either party. Before the offer s specified expiration time, the Government may accept an offer (or part of an offer), whether or not there are negotiations after its receipt, unless a written notice of withdrawal is received before award. (End of Addendum to 52.212-2) Offerors are advised to include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications Commercial Items, with the offer. 52.212-4, Contract Terms and Conditions--Commercial Items applies to this acquisition 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders--Commercial Items (JUL 2020) FAR 52.212-5 applies to this acquisition with the following FAR clauses incorporated by reference; FAR 52.204-10 Reporting Executive Compensation & First-Tier Subcontract Awards (JUN 2020) (Pub. L. 109-282) (31 U.S.C. 6101 note) FAR 52.209-6 Protecting the Government s Interest When Subcontracting with Contractors Debarred, Suspended, or Proposed for Debarment (JUN 2020) (31 U.S.C. 6101 note) FAR 52.219-28 Post Award Small Business Program Representation (MAY 2020) (15 U.S.C 632(a)(2)) FAR 52.222-3 Convict Labor (JUN 2003) (E.O. 11755) FAR 52.222-19 Child Labor Cooperation with Authorities and Remedies (JAN 2020) (E.O. 13126) FAR 52.222-21 Prohibition of Segregated Facilities (APR 2015) FAR 52.222-26 Equal Opportunity (SEP 2016) (E.O. 11246) FAR 52.222-35 Equal Opportunity for Veterans (JUN 2020) (38 U.S.C. 4212) FAR 52.222-36 Equal Opportunity for Workers with Disabilities (JUN 2020) (29 U.S.C. 793) FAR 52.222-37 Employment Reports on Veterans (JUN 2020) (38 U.S.C. 4212) FAR 52.222-50 Combating Trafficking in Persons (JAN 2019) (22 U.S.C. chapter 78 and E.O. 13627) FAR 52.223-18 Encouraging Contractor Policies to Ban Text Messaging While Driving (JUN 2020) (E.O. 13513) FAR 52.225 5 Trade Agreements (OCT 2019) (19 U.S.C. 2501, et seq., 19 U.S.C. 3301 note) FAR 52.225-13 Restrictions on Certain Foreign Purchases (JUN 2008) (E.O.'s, proclamations, and statutes administered by the Office of Foreign Assets Control of the Department of the Treasury) FAR 52.232-33 Payment by Electronic Funds Transfer System for Award Management (Jul 2018) (31 U.S.C. 3332) Additional contract requirements or terms and conditions: N/A 52.252-2, Clauses Incorporated by Reference (Feb 1998) This contract incorporates one or more clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause may be accessed electronically at this/these address(es): http://www.acquisition.gov/far/index.html http://www.va.gov/oal/library/vaar/ The following FAR clauses are incorporated by reference: FAR 52.204-13 System for Award Management Maintenance (OCT 2018) FAR 52.204-18 Commercial and Government Entity Code Maintenance (JUL 2016) FAR 52.209-11 Representation by Corporations Regarding Delinquent Tax Liability or a Felony Conviction under any Federal Law (Feb 2016) FAR 52.219-6 Notice of Total Small Business Set-Aside (DEVIATION 2019-01) FAR 52.232-40 Providing Accelerated Payments to Small Business Subcontractors (DEC 2013) The following VAAR clauses are to be incorporated by reference: VAAR 852.203-70 Commercial Advertising (NOV 2008) VAAR 852.211-70 Service Data Manuals, (NOV 1984) VAAR 852.212-71 Gray Market Items (APR 2020) VAAR 852.212-72 Gray Market and Counterfeit Items (MAR 2020) VAAR 852.219-10 VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside (JUL 2019 Deviation) VAAR 852.219-74 Limitations on Subcontracting Monitoring and Compliance (JUL 2018) VAAR 852.232-72 Electronic Submission of Payment Requests (NOV 2012) VAAR 852.246-71 Rejected Goods 52.252-1, Solicitation Provisions Incorporated by Reference (Feb 1998) This solicitation incorporates one or more solicitation provisions by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. The offeror is cautioned that the listed provisions may include blocks that must be completed by the offeror and submitted with its quotation or offer. In lieu of submitting the full text of those provisions, the offeror may identify the provision by paragraph identifier and provide the appropriate information with its quotation or offer. Also, the full text of a solicitation provision may be accessed electronically at this/these address(es): http://www.acquisition.gov/far/index.html (FAR) http://www.va.gov/oal/library/vaar/index.asp (VAAR) The following FAR provisions are to be incorporated by reference: FAR 52.204-7 System for Award Management (OCT 2018) FAR 52.204-16 Commercial and Government Entity Code Reporting (JUL 2016) FAR 52.214-21 Descriptive Literature (APR 2002) The following VAAR provisions are to be incorporated by reference: None The Defense Priorities and Allocations System (DPAS) does not apply. Date and Time offers are due to Loretta.Schmidt@va.gov by 12:00pm MT, Monday, September 28, 2020. Name and email of the individual to contact for information regarding the solicitation: Loretta Schmidt Loretta.Schmidt@va.gov
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/85e97aaaf2b0401487495f6bc09bc632/view)
 
Place of Performance
Address: VA Montana Health Care System 3687 Veterans Dr., Ft. Harrison, MT 59636, USA
Zip Code: 59636
Country: USA
 
Record
SN05815915-F 20201002/200930230146 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.