Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF SEPTEMBER 04, 2020 SAM #6854
SOLICITATION NOTICE

65 -- AUDIOLOGY BOOTHS

Notice Date
9/2/2020 9:52:29 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
250-NETWORK CONTRACT OFFICE 10 (36C250) DAYTON OH 45428 USA
 
ZIP Code
45428
 
Solicitation Number
36C25020Q0783
 
Response Due
9/7/2020 2:00:00 PM
 
Archive Date
11/06/2020
 
Point of Contact
Erik Fallo, Contract Specialist, Phone: 240-215-0608
 
E-Mail Address
Erik.Fallo@va.gov
(Erik.Fallo@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
Q&A Will there being ventilation to the roof?   (Yes) No exhaust. Booth & Control in the same area?  (Yes) yes. How many drops for HVAC, intact and exhaust, and locations?  (Qty of 6 2 above each booth, location TBD). Supply and return for each section, attached sheet indicates 2 supplies and 1 return though. HVAC locations of supply and return, and qty into the booths?  (John to mark on drawings and provide). Location doesn t matter just mark them either return or supply. Elevator height for booths and location? (Eng.) 92 Door to booth comes to the platform?  The platform was built based on the attached drawing which called for a 4 ¾ rise. Carpet and padding total thickness into booths?  To ensure flush with doors or will shimmy needed? Ramp floor covering is to be Luxury Vinyl Tile. Height & width of booth door standard spec for ADA? VA follows Architectural Building Act (ABA). Will each booth be on own electrical circuit?  Lighting power outside of booth?  Pigtail? Dedicated 20 amp circuit to each suite pig tail. Carpet needed in the booth? Attached sample of carpeting being used in the rest of 4th floor. Phone and Data Lines into control room, number of cables? 4 data cables to each suite, phones will run thru the computer port.        12.) Width of platform at window isn t wide enough for booth doors to open properly. The platform area at the window will be extended to match (the wall on left side of picture).
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/df9636763adc4dd08467ab4b97ab1c23/view)
 
Place of Performance
Address: Marion VAMC Bldg 138 1700 E 38th St, Marion, IN 46953, USA
Zip Code: 46953
Country: USA
 
Record
SN05784831-F 20200904/200902230145 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.