SOLICITATION NOTICE
66 -- Bench-Top Purification System
- Notice Date
- 7/30/2020 11:32:18 AM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- USDA ARS NEA AAO ACQ/PER PROP BELTSVILLE MD 20705 USA
- ZIP Code
- 20705
- Solicitation Number
- 1007061
- Response Due
- 8/14/2020 9:00:00 AM
- Archive Date
- 08/29/2020
- Point of Contact
- John C. Wilkinson, Phone: 3015043443
- E-Mail Address
-
john.wilkinson@ars.usda.gov
(john.wilkinson@ars.usda.gov)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- This is a combined Synopsis/solicitation for the United States �Department of Agriculture, �Agriculture Re search Service, �prepared in accordance with the format to Subpart 12.6, as supplemented with additional information included in this solicitation. This announcement constitutes the only solicitation, quotes are being requested and a written notice, will not be issued. Solicitation Number �1007061 - is issued as a request for quotation (RFQ). This solicitation �document �incorporates �provisions and �clauses which are in effect through Federal Acquisition Circular 2020-06 dated June 5, 2020.� �This solicitation shall be reserved exclusively for small businesses� with a small business size standard of 1000 employees - referencing North American Industrial Classification Code 334516 �� �SHIP TO ADDRESS � 600 E. Mermaid Lane - �Wyndmoor, Pennsylvania 19038 ��� Please make sure You include (Not to Exceed) Shipping Charges to the address listed directly above � when submitting Your quote. � Minimum requirements � Specifications of Bench-Top purification system Bench-top purification machine should provide purification of small- and large-scale reaction products. It should be useful for purification of triglycerides, fatty acid methyl esters, fatty acid amides, carbohydrates, polymers, and natural products. The purification machine should be equipped with PDA detectors, normal/reverse columns, and auto fraction collector. The purification machine should be compatible with ELSD detector. The machine should also have the capability to automatically mix solvents. The machine should be operated with Programmable Electronic Control for complete system and it should be easy to operate. Specification Pumping system ���� ���: Pressure range up to 3000 psi �����������������������������������: Flow rate range from 10ml/ min to 100 ml/min PDA detector����������� � :� Built in PDA detector with acceptable sensitivity and limit �������������������������������������of detection: 200-800nm scanning range Dual wavelength capability Flow cell volume 40ul Drift � 1 x 10-3 AU/hr Nose - +/- 5 x 10-5 AU Full Scanning mode in 3D view Built in Lamp Counter���������� Fraction collector �� ����: It should hold medium size test tubes. ��������������������������������������It should not be open to the air (it should be in a closet) Column Chamber������� : It should accommodate different size normal and reverse phase� ���������������������������������������Columns. Columns��������������������� : Significant amount of columns should be provided at the beginning �������������������������������������������� and the columns should be accessible and affordable. Solvent consumption:� : Minimum solvent consumption and compatible with the ����������������������������������������common organic solvents. Wide range of solvent capability �����������������������������������������including Hexane, Ethyl Acetate, dichloromethane, Acetonitrile & �����������������������������������������Methanol Floor space�������������������� : Minimum space. Certification :��������������� : Certified by responsible authorities and widely used in organic labs ________________________________________________________________________________________ Clauses/Provisions Incorporated by reference: This requirement incorporates one or more clauses by reference with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause may be accessed at the following address: https//www.acquisition.gov/far. 52.212-5 - Commercial Items (JULY 2020) 52.204-7 - System for Award Management (OCT 2018 ) 52.204-13 - System for System for Award Management Maintenance ( OCT 2018) 52.204-16 - Commercial and Government Entity Code Reporting (JULY 2016) 52.209-2 - Prohibition on Contracting with Inverted Domestic Corporations - Representation ( NOV 2015) 52.212-1 - Instructions to Offerers Commercial Items (JUNE 2020) 52.212-4 - Contract Terms and Conditions-Commercial Items ( OCT 2018 ) 52.223-1 - Bio-Based Product Certification (MAY 2012) 52.232-39 - !Jnenforceability of Unauthorized Obligations ( JUNE 2013) 52.232-40 - Providing Accelerated Payments to Small Business Sub� contractors (DEC 2013) 52.237-2 - Protection of Government Buildings, Equipment and Vegetation (APR 1984) No late vendor quotes or vendor questions shall be accepted referencing the above solicitation number. �All Vendor Questions, �are due via email by no later than Friday August 7, 2020� by 12:00 noon E.S.T �to John.Wilkinson@usda.gov. �I, John Wilkinson will respond back to all vendor questions via email referencing the above solicitation number - �by No later than August 11, 20200 by 12:00 noon. �Oral Communications are not acceptable in response to this requirement.� All quotes are due via email to me: John.Wilkinson@usda.gov �by no later than �12:00 p.m. E.S.T. �on Friday August 15, 2020 , 2020. Anticipated award date is August 18, 2020 �or shortly thereafter. � Important Note: �the vendor who offers the - ���Best Value to the Federal Government - � �which meets all of the above USDA end-user requirements-specifications shall be awarded a USDA Purchase Order.� Special Note � The vendor - �must � already - �have their companies Dun and Bradstreet Number --mandatorily - already be registered by July 29, 2019 �- as both - current and active at the web site: www.beta.sam.gov �at phone no. 1-866-606-8220.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/fe4ac03d666e425a8a384ac377519d63/view)
- Place of Performance
- Address: Glenside, PA 19038, USA
- Zip Code: 19038
- Country: USA
- Zip Code: 19038
- Record
- SN05740688-F 20200801/200730230155 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |