Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 30, 2020 SAM #6818
SOLICITATION NOTICE

H -- SDVOSB SET ASIDE | Boiler Safety Device Testing St. Cloud VAMC

Notice Date
7/28/2020 8:23:31 AM
 
Notice Type
Presolicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
NETWORK CONTRACT OFFICE 23 (36C263) Saint Paul MN 55101 USA
 
ZIP Code
55101
 
Solicitation Number
36C26320Q0625
 
Response Due
8/7/2020 10:59:00 PM
 
Archive Date
09/07/2020
 
Point of Contact
David A. Raad, Contract Specialist, Phone: 605-347-2511 x6851
 
E-Mail Address
david.raad@va.gov
(david.raad@va.gov)
 
Small Business Set-Aside
SDVOSBC Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
 
Awardee
null
 
Description
DEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTERS BOILER PLANTS STATEMENT OF WORK Safety Device Testing SERVICE: Contractor to provide: The contractor shall provide equipment, labor, tools and materials to perform Safety Device testing on four (4) Boiler Systems, DA and surge tank at the St. Cloud VA. A. GENERAL: The contractor shall perform safety device testing on the boilers as outlined in the VHA Boiler Plant Safety Device Testing Manual, Fourth edition. Contractor shall report the results using the prescribed forms and methods. Contractor is responsible for all costs for transportation, lodging, meals and other personal necessities for its employees and or subcontractors (as applicable). Contractor is responsible for the shipping costs and logistics for all tools and equipment necessary for the performance of this contract. Work must be performed between the hours of 8:00 am and 4:00 pm. If a boiler plant, site or national emergency develops, Contractor will cease testing at the request of site personnel. Boiler plant must maintain operational readiness per VHA Directive 1810, Page 5, para 8, section c. Appendix A (d) (N+1 Minimum Requirements). No more than one boiler may be out of service at any given time for test or maintenance. At the conclusion of the site work, the Contractor will hold an exit meeting with appropriate VA representatives for the site to highlight preliminary findings. The Contractor shall identify deficiencies and steps that can be taken by the VA to address the identified deficiencies. A VA ST Cloud Contractor badge shall be worn by all Contractor employees while on premises. Contractor badges are issues in B-3, second floor, Facilities Maintenance and Operations Office. The C&A requirements do not apply, a Security Accreditation Package is not required. SPECIAL NOTE: Any anticipated sub-contracting work shall be presented in a sub-contracting plan, which is to include the identity of the sub-contractor who will be performing the work. The CO and the COR must approve, in writing, any sub-contract work prior to its commencement. B. SPECIFICS: Safety Device Testing; Contractor shall perform each test as detailed in the VHA Boiler Plant Safety Device Testing Manual, Fifth edition. 1. The Contractor is responsible for the identification and inspection of all appropriate areas and items related to this scope of work required to complete a comprehensive inspection. The on-site Inspection shall be in compliance with ""VHA Boiler Plant Safety Device Testing Manual -Fourth Edition"" and contain information observed through first-hand inspection and testing. In no case shall an inspection test render any boiler un-useable by the test alone. The plant consists of the following boilers; a. (3) Cleaver Brooks Fire Tube Boilers, Model 200-600-200, Built in 2008. b. (1) Cleaver Brooks Fire Tube Boiler, Model 200-400-200, Built 2008. c. Surge tank. Stamp# 13138. Serial# 08407. Max allowable working pressure 25 psi at 267 deg. Min allowable working pressure -20 deg. at 25 psi. Year built 2008. d. DA tank. Stamp# 13194. Serial# 08434. Max allowable working pressure 50 psi at 275 deg. Min allowable working pressure -20 deg. at 50 psi. Year built 2008. 2. Substitution of test procedures shall be rare. Whenever practicable, the exact test shall be performed. If a substitute test method is required to meet the intent of the test outlined in the manual, the alternate method shall be reviewed by the Boiler Plant Supervisor and the Section Chief/Assistant Chief. The results of the test shall be reported on the prescribed form and a notation of: a. Why the prescribed test could not be performed. b. The details of the alternate method used. ATTACHMENTS: 1 - VHA Boiler Plant Safety Device Testing Manual -Fourth Edition. 2 - VHA Directive 1810, Boiler and Boiler Plant Operations 3 - Boiler Device Testing Data Sheet (for use or reference) 4 - Low O2 Data Sheet (for use or reference) VA St Cloud Points of Contact; Damon Harrison, Facilities Maintenance Supervisor, 320-252-1670 x 6829 Gary Johnson, Maintenance and Operations Asst. Chief, 320-252-1670 x 6506 St Cloud VA Boiler Plant, 320-252-1670 x 6347
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/45adf1c0cb864b8089266ed4bfcb6b2c/view)
 
Place of Performance
Address: Department of Veterans Affairs ST CLOUD VAMC 4801 Veterans Drive, St. Cloud, MN 56303, USA
Zip Code: 56303
Country: USA
 
Record
SN05735857-F 20200730/200728230138 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.