Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JULY 15, 2020 SAM #6803
MODIFICATION

Z -- RRAD B551 and 561 Repairs

Notice Date
7/13/2020 6:12:02 AM
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
US ARMY ENGINEER DISTRICT FT WORTH FORT WORTH TX 76102-6124 USA
 
ZIP Code
76102-6124
 
Solicitation Number
W9126G20B0031
 
Response Due
7/27/2020 7:00:00 AM
 
Archive Date
08/11/2020
 
Point of Contact
Kimberly Bass, Phone: 817-886-1066, John H. Rodgers, Phone: 817-886-1048
 
E-Mail Address
kimberly.e.bass@usace.army.mil, john.h.rodgers@usace.army.mil
(kimberly.e.bass@usace.army.mil, john.h.rodgers@usace.army.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
------------------------------------------------------THIS IS ONLY A SOURCES SOUGHT--------------------------------------------------------- Please do not submit any Proposals at this time. RRAD B551 and B561 Renovation Project Description This project comprises the complete Restoration and Modernization of Buildings B551 and B561 at Red River Army Depot�(RRAD), Texarkana, TX. Renovation will increased wall height but will not replace the building walls. Existing walls shall be reinforced to accommodate for the renovations. Buildings 551 and 561, each provide 91k SF of depot level rebuild operation space capable�of supporting multiple depot programs, including MaxxPRO, Military All-Terrain Vehicle (MATV), Family of Medium�Tactical Vehicles (FMTV), Cougar, High Mobility Multipurpose Wheeled Vehicle (HMMWV), and Trailers for Army,�Navy, Marines, and Field Maintenance Squadron (FMS). B551: 1. The following equipment items shall be removed and stored for reinstallation in the building: radiant heaters, HVLS fans,�blue �turbo� fans, hose reels, and electrical cord reels. 2. The existing fire alarm system components shall be removed and stored for reinstallation in the building. 3. The existing air compressors (located on the west and south sides of the building) and associated equipment and canopy�shall remain for reconnection to the building. 4. Portions of walls shall be selectively demolished for the installation of new roll-up doors. 5. Repair structural components in failing state and provide a standing seam metal roof. 6. Provide a code compliant electrical distribution system. 7. Provide a code compliant fire sprinkler system. 8. Provide a code-compliant fire alarm/mass notification system for each building, utilizing the reclaimed components to the�greatest extent practical. 9. Provide exhaust fans, HVLS fans, and column/wall mounted fans in each building, utilizing the reclaimed fans to the greatest extent practical. 10. Provide a compressed air distribution system and accessories in each building. 11. Provide overhead lifting in each building. B561: 1. The following items shall be removed and stored for reinstallation in the RM building: radiant heaters, HVLS fans, blue��turbo� fans, yellow �cool zone� fans, and LED light fixtures. 2. The existing material handling equipment (3-ton floor-mounted bridge cranes and 1- and 3-ton floor mounted jib boom�cranes) shall be removed and returned to the government for disposition. 3. The existing fire alarm system components shall be removed and stored for reinstallation in the building. 4. The existing air compressor (located on the south end of the building) and its associated equipment and canopy shall�remain for reconnection to the building. 5. The following existing facilities shall remain for reconnection to the building: a. 14�x44� restrooms, 2 each, one at the northwest corner and one at the southwest corner b. 26�x42� break room on the east side c. 12�x40� office on the east side 6. Portions of walls shall be selectively demolished for the installation of new roll-up doors. 7. Repair structural components in failing state and provide a standing seam metal roof. The standing seam metal roof system�will protect the integrity of the structural components in the existing structural system. 8. Provide a code compliant electrical distribution system. 9. Provide a code compliant fire sprinkler system. 10. Provide a code-compliant fire alarm/mass notification system for each building, utilizing the reclaimed components to�the greatest extent practical. 11. Provide exhaust fans, HVLS fans, and column/wall mounted fans in each building, utilizing the reclaimed fans to the�greatest extent practical. 13. Provide a compressed air distribution system and accessories in each building. 14. Provide overhead lifting in each building. Abatement of asbestos-containing materials shall be accomplished in both buildings, particularly in the renovated areas.��B551 asbestos materials are roofing, caulking, foundation tar, fire doors, and the exterior wall coating (beneath paint). B561�asbestos materials are roofing, caulking, and fire doors. Estimated POP days:� 660 Place of Contract Performance: Red River Army Depot Texarkana , Texas 75507 United States
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/5502c042e7ad4ebca41995f959dc6228/view)
 
Place of Performance
Address: Texarkana, TX 75501, USA
Zip Code: 75501
Country: USA
 
Record
SN05718606-F 20200715/200713230146 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.