MODIFICATION
65 -- Provide and Install Audiology Booth-LAX CBOC (VA-20-00043404)
- Notice Date
- 6/24/2020 1:05:13 PM
- Notice Type
- Solicitation
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- 252-NETWORK CONTRACT OFFICE 12 (36C252) MILWAUKEE WI 53214 USA
- ZIP Code
- 53214
- Solicitation Number
- 36c25220Q0628
- Response Due
- 7/8/2020 11:00:00 AM
- Archive Date
- 10/08/2020
- Point of Contact
- Christopher Rodriguez, Contract Specialist, Phone: 414-844-4880
- E-Mail Address
-
christopher.rodriguez5@va.gov
(christopher.rodriguez5@va.gov)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- Provide, install and certify for ambient noise, one (1)� new, modular, single wall, (Type II), audiometric testing room, with a 4"" minimum thick, integral sound rated floor system and all required assemblies, that meets all ANSI (American National Standards Institute) S3.1 ""Maximum Permissible Ambient Noise Levels for Audiometric Test Rooms"" requirements and that meets the following criteria; � Assembled room shall fit in a pre-cast concrete pit, installed by others, with a one-inch space around all vertical room surfaces, that has the following dimensions; 120 5/8"" wide by 109 5/8"" long with a depth of 7"". � Integral floor system shall have RD-3, green, isolators installed on testing room floor assembly to isolate the booth from the floor of the existing concrete pit. � Audiometric testing room shall have one (1) right hand swinging door, with a 42"" wide x 73"" tall minimum clear opening. Door shall swing outward and shall be located on the right side of the front elevation of the testing booth. Door shall have a deadbolt, keyed lock. � Audiometric testing room integral ceiling panels shall have one (1) 3"" diameter, fire sprinkler head access hole installed. Access hole shall be as centrally located within the assembled testing room as possible. Sprinkler head and related piping installed by others. � Audiometric testing room integral ceiling panels shall have two (2) 8"" diameter, one (1) each, static intake and exhaust HVAC ceiling silencers with collars. All HVAC connections by others. � Audiometric testing room shall have one (1) 24"" wide by 30"" tall, 1/4"" double glazed, acoustic, one-way glass window installed on the right elevation. � Audiometric testing room shall have one (1) jack panel for clinical audiometric connections. Jack panel shall be located on the left elevation of testing booth and shall have a minimum of twelve (12) 1/4"" phone jacks, two (2) USB (Universal Serial Bus) ports and one (1) 1"" pass-through port/opening. � Audiometric testing room shall have all LED lighting, interior to the booth with integral light switch located adjacent to the testing booth door. � Interior of the audiometric testing room shall have carpet flooring. � Audiometric testing room shall have five (5) duplex electrical outlets installed. Three (3) duplex outlets on the interior of the booth, spaced evenly and two (2) on the exterior. Exterior electrical outlets shall be installed on the left elevation of the booth and adjacent to the the jack panel. � Audiometric testing room shall have three (3) double-duplex electrical outlets installed. Two (2) double-duplex outlets on the interior of the booth, spaced evenly and one (1) on the exterior. Exterior electrical outlets shall be installed on the left elevation of the booth and adjacent to the jack panel. � Audiometric testing room electrical system and components shall be UL (Underwriters Laboratory) listed and NEC (National Electric Code) compliant and shall be rated for 120v, 20a, 60Hz, and shall be installed per the most current NEC. � Audiometric testing room shall include three (3) empty utility box's, each with pull wire installed. One (1) utility box shall be for a fire alarm strobe, one (1) utility box shall be for a thermostat and one (1) utility box shall be for data connections. Fire alarm strobe and thermostat connections and components shall be VA provided and installed by others. � Provide one (1) each, audiometric testing room Operators manual and Service manual.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/f4565a80561840bfb1d075366444c960/view)
- Place of Performance
- Address: La Crosse, WI, USA
- Country: USA
- Country: USA
- Record
- SN05701044-F 20200626/200624230146 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |