SPECIAL NOTICE
J -- REMOVAL, FILL, AND INSTALL OF NOTROGEN BOTTLE ON CGC MORRO BAY IN CLEVELAND, OH
- Notice Date
- 6/18/2020 2:56:36 PM
- Notice Type
- Special Notice
- NAICS
- 336611
— Ship Building and Repairing
- Contracting Office
- SFLC PROCUREMENT BRANCH 2(00085) ALAMEDA CA 94501 USA
- ZIP Code
- 94501
- Solicitation Number
- 70Z08520QP45F1200
- Response Due
- 6/19/2020 9:00:00 AM
- Archive Date
- 07/04/2020
- Point of Contact
- William A. M. Sword, Phone: 5106375901, BARBARA FALERO, Phone: 5106375973
- E-Mail Address
-
william.a.swordjr@uscg.mil, BARBARA.FALERO@USCG.MIL
(william.a.swordjr@uscg.mil, BARBARA.FALERO@USCG.MIL)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- WATER MIST NITROGEN BOTTLES THE USCGC MORRO BAY (WTGB 106) Conditions Existing: The nitrogen bottles for the installed water mist firefighting system are depleted due to standby ship service air PSI loss, causing activation. � Location: Upper Main Motor Room Reference Plans/Name Plate Data: 140-WTGB-555-02, 140-WTGB-185-006 � Work to be accomplished: All 29 75.9kg 50L Nitrogen Cylinders will need to be removed from the cutter, transported to company to be refilled to a minimum of 180 bar, maximum of 200 bar, then reinstalled.� If nitrogen cylinder valves leak, contractor is to rebuild valves. � Protective Measures: Protective coverings shall be furnished and installed to seal off and protect non-affected vessel�s components, equipment, and spaces near the work area to protect against contamination during the performance of work. When transporting nitrogen cylinders from upper motor room to truck, special care is to be taken of the nonskid on the weather decks.� Bottles should not be dragged across the nonskid to avoid damaging the deck. � INTERFERENCES: Solenoid valves connected to each nitrogen cylinder. � SAFETY: Ensure water mist system is secured and tagged out by ships force prior to removal of cylinders. � TESTS/DOCUMENTATION: Valve tests, leak tests, operational tests. � UNIT ASSISTANCE: Secure and tag out water mist system.� Operational test upon reinstallation. Cutter Availability: 30 JUN -12 JULY (preferred timeframe), 18 AUG � 29 SEPT (Dockside).� All at cutter homeport. �
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/83f0c069e6b44edab4c360db18f6a21c/view)
- Place of Performance
- Address: Cleveland, OH 44114, USA
- Zip Code: 44114
- Country: USA
- Zip Code: 44114
- Record
- SN05695197-F 20200620/200618230156 (samdaily.us)