Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF JUNE 12, 2020 SAM #6770
SOLICITATION NOTICE

U -- Respi Sim Pro system

Notice Date
6/10/2020 7:28:28 AM
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
333318 — Other Commercial and Service Industry Machinery Manufacturing
 
Contracting Office
FA4800 633 CONS PKP LANGLEY AFB VA 23665 USA
 
ZIP Code
23665
 
Solicitation Number
FM480000840057
 
Response Due
7/10/2020 1:00:00 PM
 
Archive Date
07/25/2020
 
Point of Contact
Tyzsa M. Davis, Phone: 7572255581, James Carnes, Phone: 7572253150
 
E-Mail Address
tyzsa.davis@us.af.mil, james.carnes.2@us.af.mil
(tyzsa.davis@us.af.mil, james.carnes.2@us.af.mil)
 
Small Business Set-Aside
SBA Total Small Business Set-Aside (FAR 19.5)
 
Description
ASL 5000 RespiSIM System Educational Package - PRO w/2 year service plan, RespiPatient Consumables Replacement package (31 10 865), OxSIM SpO2 Simulator (31 00 340), Ventilator Interface Kit option (31 00 765), and shipping. A. Minimum Clinical Performance Requirements: 1. Size: Fully assembled Pro Package: 69� x 24� x 64� (38�L when folded) RespiPatient manikin lying on tabletop: 27.5"" x 18.25"" x 9.5"", approximately 23 lbs. ASL 5000: 8.6"" x 16.8"" x 12.4"", approximately 22 lbs. 2. Patient Safety Features: N/A 3. Operator Control Features: �Simulate any respiratory patient scenario including disease states and deteriorating/improving patient states 4. Software/ Hardware requirements: �The RespiSim Software enhances the use of the ASL 5000 Breathing Simulator as a ventilator management teaching system. The software allows instructors to stay in control of the simulation and gives Airman the full view of patient-ventilator interaction, from vital signs to x-rays, in structured, multi-stage simulations. Features include: �Instructor Dashboard for easy and comprehensive control over all aspects of the Simulation �Rich debriefing environment including recordings of entire sessions with waveforms and event markers �Vital signs monitor to display lab results, x-rays and ABG values 5. Interoperability/connectivity with other equipment/systems or existing systems already in place: N/A, this is a stand-alone system and does not require any interaction with the existing systems. 6. Communication capabilities with other equipment/systems or existing systems already in place: N/A, this is a stand-alone system 7. Unique requirements that cannot be meet by other manufactures include: � Resistance and compliance parameter ranges allow for virtually any patient condition � Resistance and compliance set by instructor using physiologically accurate units that take the guess-work out of creating disease states � Simulate independent inspiratory and expiratory resistance to realistically create disease states that rely on specific expiratory resistance, such as asthma � Simulate independent left and right lung compliance � Define non-linear compliance curves �The ASL 5000's 0 - 150 BPM range makes it compatible with the full range of neonatal and pediatric patients � Allows users to set variable efforts from 0 to 100 cmH20 (negative pressure) which allows for simulating apneic patients all the way to fully healthy spontaneously breathing patients � Triggers the ventilator even with low trigger sensitivity � Simulate spontaneous breathing trial scenarios � Simulate any type of patient-ventilator dysynchrony scenario (inspiratory, expiratory, trigger, and cycle) � Control the patient's I:E ratio to either synchronize or purposefully dysynchronize the Ventilator � Changes to ASL 5000 parameters are applied almost immediately (1-2 breaths) � Changes can be set to apply gradually (up to 12 breaths) via a user-controlled slider � Randomized breath patterns � Time-varying parameters � Interacts realistically with all modes of ventilation including Pressure/Volume Control, HFOV, and particularly spontaneous modes such as Pressure Support, ASV, and PAV � Can hold PEEP over 20 cmH2O � Change between volume and pressure control modes seamlessly on the same patient without re-adjusting lung parameters or interrupting scenario � Connect ASL 5000 directly to ventilator with no manikin to simulate neonatal or pediatric patients � Able to interact with High Frequency Oscillatory Ventilation (HFOV) � Integration with RespiSim Curriculum Modules � Chest rise varies from shallow to deep based on breathing effort � Quick Choice Menu includes Normal, ARDS, Asthma, COPD for adults; CF for pediatrics; and BPD and IRDS for neonates; All with variable severity � Real-time waveform data displayed for instructor (flows, pressures, volumes, PIP, PEEP, Pplat, Rate, Tidal Volume) � Using its internal pressure sensor, the ASL 5000 captures feedback from the ventilator and provides real-time feedback to the instructor displayed in the RespiSim Software � The data can also be pushed to a separate monitor for use as teaching tool � further enhancing the ASL 5000's use B. Source Considerations: Universal input - Connect the ASL 5000� to a properly grounded wall outlet provided 100 - 240 V AC, 50 - 60 Hz C. Biomedical Tech Considerations: Training includes: two day on-site training with a respiratory therapist and Modes of Ventilation (package of 5 curriculum modules) and Patient-Ventilator�Synchrony in the Volume Assist-Control Mode (package of 4 curriculum modules) are included Service and Maintenance Options: � RespiSim System 1-year Extended Warranty for Pro Package � 1-year extension of manufacturer�s warranty (2 total years). Covers repairs due to manufacturer�s defects or workmanship. Does not cover damages resulting from improper use, negligence, disassembly, unauthorized service, and unauthorized modification. Computer/monitors are excluded from warranty. Initial purchase only. � RespiSim System 2-year Extended Warranty for Pro Package � 2-year extension of manufacturer�s warranty (3 total years). Covers repairs due to manufacturer�s defects or workmanship. Does not cover damages resulting from improper use, negligence, disassembly, unauthorized service, and unauthorized modification. Computer/monitors are excluded from warranty. Initial purchase only. � 2-year Service Plan for Educator ASL 5000 � Once, within this period, at a time of customer�s choice the following services will be performed to the ASL 5000�: Inspection of the ASL 5000�, calibration with data, replacement of piston seals, and lubrication of moving parts. Does not include cost of shipping. � RespiPatient Consumables Replacement Package � Includes overlay neck skin attachments (pack of 5), chest drain insert set, and needle decompression inserts (pack of two). �ASL 5000 is extremely durable - only maintenance suggested is bi-annual calibration of the ASL 5000 which will be maintained by departmental budget � Software upgrades will be budgeted for, as needed, through departmental budget
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/1c735c7cc2f944fd871f084cd78e144d/view)
 
Place of Performance
Address: Langley AFB, VA 23665, USA
Zip Code: 23665
Country: USA
 
Record
SN05685892-F 20200612/200610230154 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.