SOURCES SOUGHT
65 -- Dental Lab Services.
- Notice Date
- 3/16/2020 5:43:22 AM
- Notice Type
- Sources Sought
- NAICS
- 339116
— Dental Laboratories
- Contracting Office
- 241-NETWORK CONTRACT OFFICE 01 (36C241) TOGUS ME 04330 USA
- ZIP Code
- 04330
- Solicitation Number
- 36C24120Q0247
- Response Due
- 3/20/2020 12:00:00 AM
- Archive Date
- 04/19/2020
- Point of Contact
- Mary K. (Kathy) Bosch Mary.Bosch@va.gov
- E-Mail Address
-
mary.bosch@va.gov
(mary.bosch@va.gov)
- Awardee
- null
- Description
- Justification and Approval for: Other than Full and Open Competition The Brockton and Jamaica Plain VA Medical Healthcare Systems intends to negotiate on a sole source basis pursuant to FAR 6.302 1 Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements with James R. Glidewell Dental Ceramics located in Newport Beach, California 92660 or its authorized dealers for the purchase of Dental Lab Items, 1 Dental Laboratory Services: Those laboratory procedures that are required for the treatment of dental patients. These would include , but not be limited to, all laboratory fabrication aspects of complete dentures, removable partial dentures, fixed partial dentures and crowns, and dental implant prosthesis. PERFORMANCE WORK STATEMENT (PWS) DEFINITIONS VA Boston Healthcare System Jamaica Plain and Brockton Campuses Special Handling: Unusual circumstance may dictate the need for a dental order to be picked up, specially shipped and returned same day, overnight, or processed within a shorter time frame. Routine Handling: A dental laboratory work authorization that is usually performed and returned within a specified time frame. Turn Around Time (TAT): The length of elapsed time between pickup of the dental lab order by the contractor until the receipt of the complete order by VA Dental Service. COR: Contracting Officer s Representative. SAD: Standards of Acceptable Deliverables. Dental Laboratory Services: Those laboratory procedures that are required for the treatment of dental patients. These would include, but not be limited to, all laboratory fabrication aspects of complete dentures, removable partial dentures, fixed partial dentures and crowns, and dental implant prosthesis. Working Day: Any twenty-four hour period of the typical administrative work week, i.e. Monday through Friday (M-F). For example, if the contractor is allowed 5 working days for a prosthesis and is picked up on a Monday, it would be due back to VA the following Monday. Federal holidays occurring M-F are not considered a working day. TERM OF CONTRACT The proposed contract period is for one year 1 with four (4) 12-month option periods, one FAR 52.217-8 six month extension if exercised Anticipated Period of Performance: Base Year 05/01/2020-04/30/2021 Option Year 1 05/01/2021-04/30/2022 Option Year 2 05/01/2022-04/30/2023 Option Year 3 05/01/2023-04/30/2024 Option Year 4 05/01/2024-04/30/2025 Six Month Option 05/01/2025-08/31/2025 SCOPE The Contractor shall provide all resources necessary to accomplish the requirements described in the Performance Work Statement (PWS). The Contractor shall provide dental laboratory services outlined in this PWS. The contractor shall furnish local pickup Monday through Friday between the hours of 8:00 a.m. and 4:00 p.m. Eastern standard time. The contractor will have overnight capabilities to provide urgent orders. All labor, transportation, materials, general dental laboratory tools, equipment and supervision required to provide Dental Prostheses to the VA Boston Healthcare System, Jamaica Plain Campus 150 So. Huntington Ave. Jamaica Plain, MA 02130, Brockton Campus 940 Belmont St. Brockton, MA 02301. The Contractor requires bills to be sent on a weekly basis. No changes are to be made to the Rx without the permission of the sending provider. Contractor must have products that are 100% American Made. The dental laboratory services that may be authorized under this contract include, but are not limited to: Fabrication of porcelain fused to metal crowns and fixed partial dentures Fabrication of Full gold crowns and fixed partial dentures Implant supported crowns and fixed partial dentures Abutments Resin-bonded bridges Removable partial denture frameworks Diagnostic wax-ups for crown and bridge (C&B) cases Custom provisional C&B prostheses All-ceramic C&B prostheses Implant connecting bars (precious metal/titanium) C&B metal/titanium/zirconium substructures Application of veneering porcelain to existing/VAMC submitted metal or ceramic C&B copings and fixed partial denture (FPD) substructures. Removable Prosthesis Full Denture Set-up Full Denture Finish Denture relines and repairs Partial repairs Nightguards Bite blocks Base trays The Contractor shall provide sufficient management to ensure that the work specified in this contract is performed efficiently, accurately, on time, and in compliance with the terms and conditions of the contract. The Government reserves the right to add additional dental products and/or services, within the scope of the original contract, via a Bi-lateral modification. GENERAL REQUIREMENTS The Contractor shall provide services and support to VAMC Boston as defined herein. The Contractor shall fabricate dental prosthetic items in strict accordance with the dental laboratory order for the fabrication of dental prostheses, which shall include but not be limited to the following; all laboratory fabrication aspects of complete dentures, removable partial dentures, fixed partial dentures and crowns, and dental implant prosthesis. Special handling may be required on specific orders and will be authorized on a case by case basis by the VAMC. Special/customized fabrication standards may be required on specific orders and will be authorized on a case by case basis by the VAMC. The contractor will be a full service dental laboratory that could integrate the combined treatment needs of the prosthetic patient requiring simultaneous fixed, removable and implant prosthetics. The normal turnaround time (in working days as defined) for dental prosthetic items shall be as outlined in the following table. In case of longer turn-around times, the Contractor must notify the COR of the delay, in writing, as soon as the delay becomes known and before the maximum number of days has expired. This notification must include the reason for delay and the requested amount of additional time. 24 Hours 48 Hours 3 Days 5 Days Complete and Removable Partial Denture acrylic resin repairs Custom impression trays Diagnostic wax-up, (4teeth or less) Record base and occlusal rims Complete and Removable Partial Denture, tooth additions/repair Custom impression trays, altered cast impression Heat cured provisional restorations (4 teeth or less) Complete and Removable partial Denture, tooth set-up Articulation of cast Occlusal guard, vaccuuform Tooth Rearrangements, complete and removable partial dentures Complete and removable partial Denture, Process and Finish Cast duplications Complete and Removable Partial Denture, relines Articulation with model and die work Valplast partial Denture, process and finish Solder/Laser Weld Complete and Removable Partial Denture, rebase Valplast partial Denture, tooth set-up Transitional Removable Partial Denture, processed (3 teeth or less) Processed surgical templates Transitional partial set-up and process Cast Post and Core restorations 10 Days Milled crowns (Zirconium, e-max) Custom abutments PFM crowns and bridges Cast gold crowns Cast partial Denture framework Diagnostic wax-up (4 or more teeth) Heat cured provisional restorations (4 or more teeth) The contractor certifies that all alloys, metals, and components of dental prostheses are in compliance with and meet FDA, ANSI and American Dental Association department standards. The Contractor must assure that dental prostheses or appliances assembled or created under the contract will not be manufactured outside of the United States. American National Standards Institute (ANSI) Requirements Standards by the ANSI in cooperation with the American Dental Association Department of Standards require that all materials used for fabrication of dental prostheses meet the Standard Practices for Biological Evaluation of Dental Materials. Food and Drug Administration (FDA) Requirements Contractor must comply with the regulations governing FDA Quality System/Good Manufacturing Practices for products distributed in the United States dental laboratories. FDA regulations prohibit the use of lead in the surface material used to fabricate dental prostheses. Contractor shall provide the following services at VA Boston Healthcare System, Jamaica Plain and Brockton Campuses: Forms for the authorization of work at their facility. Once daily pick-up and delivery Monday through Friday in the Dental Clinic, to include but not limited to: All impression pouring/handling. All necessary procedures relating to Dental Laboratory Services. Contractor shall consult with the appropriate Using Service at the VAMC regarding any specific dental laboratory order. BUSINESS ASSOCIATE AGREEMENT (BAA): For your information, please find the attached Business Associate Agreement (BAA) template included as part of the solicitation. The attached BAA will be requested and shall be filled out in its entirety, signed and submitted upon award. If your company has already has an active National BAA, you may include a copy of your current National BAA in place of completing the attached BAA document. MATERIAL REQUIREMENTS Noble Alloys (Noble Metal Content must be > 25% Gold + Platinum Group) shall be used in the fabrication of full gold crowns and fixed partial dentures (bridges) and in porcelain fused to metal crowns and fixed partial dentures. As per the American Dental Association ""Revised Classification System for Alloys for Fixed Prosthodontics,"" www.ada.org/2190.aspx for Noble Alloys. The combined total of the metals (gold plus the platinum group) must be greater or equal to 25%). Metals of the platinum group are platinum, palladium, rhodium, iridium, osmium and ruthenium. The contractor shall provide porcelain fused to metal crowns and fixed partial dentures with options of metal occlusal surfaces, crown (survey) under partial denture, porcelain labial butt margin and implant crown and abutments. The contract laboratory shall identify by affixing the most recent manufacturer label to provide a description of the metal alloy components and percentages used in the fabrication of each of the requested dental prostheses. The contract laboratory shall identify in writing (per case) the type of porcelain used in the fabrication of the porcelain fused to metal dental restorations and in instances where porcelain application only is requested. The alloy used for PFM restorations shall contain less than 30% silver. Non-precious alloys (nickel and beryllium free) shall be used for resin-bonded fixed partial dentures. Cast metal partial denture frameworks shall be fabricated of a cobalt chromium metal alloy; free of nickel and beryllium. The VA system uses multiple implant systems. They are not universal. The VAMC will provide the stock abutments or ""cast-to"" custom abutments for fabrication. For ""cast-to"" abutments, the offeror will design and fabricate a suitable abutment. ORDERING Ordering Procedures - Task orders against this contract will be placed in accordance with this section. All task orders placed incorporate all terms and conditions of the contract. Ordering Officials - Task orders will be placed by ordering officials designated by the Contracting Officer (CO). Ordering officials will be from the Jamaica Plain and Brockton VA Medical Center. The ordering facility will issue a prescription to a contractor. Prescriptions constitute binding orders under this contract. SHIPPING/DELIVERY Government Packaging Orders sent to contractors will include the following information: (i) Date of order. (ii) VAMC Case Number (ii) Contract number and order number. (iii) For supplies and services, description and quantity as per prescription. (iv) Place of delivery or performance (including consignee). - A copy of the Manifest listing all of the cases being shipped will also be included. (v) Accounting and Appropriation data Shipping Method - Contractor shall use Fed Ex mail or equivalent and use express delivery service for emergency cases. Return shipping costs shall be the responsibility of the Contractor. Signature confirmation is required. All shipping and handling charges, if applicable, are required to be included as part of the line item pricing. The Government will not pay the shipping and handling charges separately and if invoiced, the shipping charges will be rejected. Shipping Locations: Jamaica Plain VA Medical Center Department of Veterans Affairs Dental Service Bldg. 1 2C Jamaica Plain Campus 150 So. Huntington Ave. Jamaica Plain, MA 02130 Brockton VA Medical Center Department of Veterans Affairs Brockton Dental Service Bldg. 3, 5th flr. 940 Belmont St. Brockton, MA 02301 Contractor Packaging - Contractor shall adhere to the following guidelines when packaging products for return to VA: Remove dies from models, wrap in cotton and place in plastic containers. Wrap all components individually in bubble wrap and secure. Pack items securely in shipping box with sufficient bubble wrap to avoid movement during shipment. All completed cases shall be disinfected and returned to the authorizing VAMC via shipping methods defined above in Section VI (2). Contractor must identify the specific type of metal used in each prosthesis with the shipment. Contents - Contractor shall include the following items in each returned product to VA: All original materials supplied by VA Chain of custody from receipt of items to packaging for shipment Itemized non-payable invoice or packing list as detailed in Section IX. A copy or original of the manufacturer label, to provide a description of the metal alloy components and percentages used in the fabrication of each of the requested dental products. Contractor shall identify in writing (per case), the type of porcelain used in the fabrication of the porcelain fused to metal dental restorations A copy of the original lab prescription from the authorizing VAMC Delinquency - Delinquent delivery shall not exceed 5% of the number of orders placed per batch, per quarter, and/or the total number of orders placed for this contract period (year). QUALIFICATIONS, LICENSES AND INSPECTION OF CONTRACTOR The VISN 1 contracting officer reserves the right to thoroughly inspect and investigate the contractor s and subcontractor s facilities and other qualifications. Please provide an organizational chart specific to the management of this contract, along with contact information. This will show which personnel will be directly involved with the contract management and be involved with daily operations (examples would be: CEO, Safety Manager, Operations Manager(s), Certified Dental Technicians, etc.) in accordance with the Statement of Work requirements. The contractor and all sub-contractor s facilities shall have all licenses, permits and certifications as required by local and state authorities. Current copies of these must be provided to the contracting officer upon request. QUALITY All dental prostheses returned from the contracted laboratory will be evaluated by the authorizing VAMC. Returned prostheses that fail to meet patient requirements will be returned to the contractor for correction, adjustment, or remake. All dental prostheses returned to the contractor for correction, adjustment, or remake shall be delivered to the authorizing VAMC within three (3) business days of date received. Communication back and forth between the VA and the Vendor is important to maintain and coordinate the quality assurance aspects of this contract. The contractor will follow the Standards of Acceptable Deliverables (SAD), which is attached. Dental Laboratory procedures and products will be assessed by the COR by using the SAD of Dental Laboratory procedures. Prostheses delivered to VA also must adhere to the following standards: Marginal integrity crown and bridge prosthetic margins are complete and closed to the marked die margins Occlusal relationship the prosthesis contacts the opposing teeth positively and lightly when biting Esthetics/anatomic contours the prosthesis matches the shape and contour of the surrounding teeth, as well as the prescribed shade/color Products not conforming to the stated requirements will require rework. Financial responsibility for rework is defined in paragraph IX. (2). Acceptable quantities of rework are defined in paragraph IX. (3). Financial Responsibility - Prostheses returned to Contractor for rework due to Contractor error shall have necessary corrections, adjustments, or remakes performed no cost to VA. Prostheses returned to Contractor for rework due to VA error will have necessary corrections, adjustments, or remakes performed at contract rates payable by VA. The Contractor must provide proof that the error was due to VA error for consideration of payment under the contract. Frequency of Rework - Rework due to contractor error shall not exceed 5% of the number of orders placed per batch, per quarter, and/or the total number of orders placed for this contract period (year). Quality Assurance Surveillance Plan (QASP): Describe your quality management system that is currently in place that will ensure the needs of the Government are met on a daily basis. Please also provide any quality certifications or licenses obtained. Please submit a Quality Assurance Surveillance Plan (QASP) as part of this technical submission. The QASP template can be found under section D (attachments), if needed. In addition to the SAD, the Government will also use the contractor s QASP to assess the quality of the delivered products. The COTR will notify the vendor in writing on a monthly basis any issues concerning quality complaints of dental laboratory items providing detailed information for the vendor to correct identified discrepancies. Cleanliness - Contractor shall adhere to OSHA standards and disinfect all dental impressions and prostheses. The contractor service requirements are summarized into Performance Standards that relate directly to mission-essential items. The Performance Standard briefly describes the minimum acceptable levels of service required for each requirement. Task # Required Service Performance Standard Monitoring Method Incentive/ Disincentive 1 Provide Dental Laboratory Services as outlined in the SOW and SAD 100% Perform services in accordance with Joint Commission on the Accreditation on Healthcare Organizations (JCACO) standards, federal regulations or accreditation regulatory entities, including, but not limited to, the American Dental Association (ADA) and the Contractor's respective state, requirements for operation as a dental laboratory. Periodic Inspection Positive/Negative Past Performance 2 Practice quality control and safety measures, including Universal Precautions for Infectious Disease Control. 100% Perform services in accordance with Joint Commission on the Accreditation on Healthcare Organizations (JCACO) standards and Safe Workplace Regulations. Random Inspection Positive/Negative Past Performance 3 Provide quality and appropriate documentation regarding the services provided. 95% Perform services in accordance with the Performance Work Statement. Customer Complaints Poor performance may result in re-performance at Contractor's expense or termination of the contract. SPECIAL REQUIREMENTS The contractor shall notify the contracting officer of any proposed changes in subcontracted dental laboratories and have prior written approval (by the contracting officer) before any changes are implemented. The contractor agrees to absorb any increase in charges as a result of any changes in subcontracted laboratories. Quality Control: Dental Laboratory procedures and products will be assessed by the COR by using the SAD of Dental Laboratory procedures (copy attached). Contractor shall provide with upon request a detailed description of quality control procedures. Contractor shall provide with upon request a detailed description of quality control policies and procedures followed by the contractor in the fabrication of dental prostheses. The contractor will provide the following, upon request, as well as provide copies during the term of the contract to the CO and COR upon request. A mutually agreeable time for pickup and delivery. Telephone numbers and contact persons to be used by the using service at the VAMC to inquire about specific dental laboratory orders. A narrative description of the laboratory s quality control program. The contractor shall maintain acceptable services, reporting systems and quality controls as specified herein. Failure to comply with the specified terms and conditions and/or failure to perform satisfactorily may be grounds for pursuing termination of the contract. STANDARDS FOR ACCEPTABLE DELIVERABLES (SAD) * All standards should be in agreement with the VA Central Dental Laboratory case requirements at http://www.va.gov/ntxcdl. Complete Dentures Master Casts Base is 10mm thick at the thinnest portion of the cast 3mm wide land area throughout the circumference of the cast Sulcular depth 3mm on buccal, to follow the contour of the buccal vestibule Sulcular depth 3mm on lingual to follow the contour of the vestibule Free of bubbles and defects All anatomic areas of impression included on cast Tongue area, flat across the arch Base is parallel to the plane of occlusion or residual ridge B. Impression Trays Rigid and fabricated from the appropriate material Covers all indicated anatomy Handles do not interfere with border molding movements, formed as prescribed, so as not to displace facial musculature Impression material retentive features included in the tray as prescribed Record Base Is well adapted to the residual ridge Covers all indicated anatomy Is extended to the land area Is adequately thick for rigidity Is smooth and free of sharp area Occlusion Rim, Maxillary Is fabricated from the prescribed baseplate wax Is 10mm wide in the posterior section The posterior sections are placed over the crest of the residual ridges Is straight from the buccal aspect of the record base border to the buccal aspect of the occlusion rim Taper in width to 3mm in the anterior section Anterior section angles 5 degrees anteriorly from the horizontal Anterior is 22mm long from the extent of the labial flange Posterior is 18mm long from the extent of the buccal flange All wax is smooth, without voids Adheres well to the record base The occlusal plane is flat, generally parallel to the residual ridge Occlusion Rim, Mandibular Is fabricated from the prescribed baseplate wax Is 10mm wide in the posterior section The posterior sections are placed over the crest of the residual ridges The posterior sections stop at the beginning of the upward incline of the residual ridges Is straight from the buccal aspect of the record base border to the buccal aspect of the occlusion rim Tapers in width to 3mm in the anterior section Anterior section angles 5 degrees anteriorly from the horizontal Anterior is 18mm long from the extent of the labial flange Posterior extends to the top of the retro-molar pad All wax is smooth, without voids Adheres well to the record base The occlusal plane is flat, ideally parallel to residual ridge Wax Trial Dentures, Maxillary The midline of the arranged teeth matches the marked midline of the occlusion rims The incisal edges of the anterior teeth are placed in the same plane as the incisal surface of the occlusion rim The occlusal scheme by default is to a Class I occlusion with a balanced set-up, unless otherwise specified. The inter-dental wax fills the embrasures up to the contact points. Adequate inter-dental wax fills the embrasures to allow for finishing of the acrylic resin A 4mm band of simulated attached gingiva is present, elevated to simulate buccal bone The palatal area is 2mm thick A 1mm band of wax is palatal to the posterior teeth to allow for finishing of the acrylic resin Wax does not overlap onto the beginning/palatal of the ridge-lap area of the anterior teeth The opposing occlusion contacts into proper interdigitation at the established vertical dimension of occlusion Wax Trial Dentures, Mandibular The midline of the arranged teeth matches the marked midline of the occlusion rims The facial surfaces of the anterior teeth are placed in the same plane as the contoured facial surface of the occlusion rims The incisal edges of the anterior teeth are placed to develop the horizontal and vertical overlap necessary for the individual clinical requirements The occlusal plane of the mandibular posterior teeth is at the appropriately indicated superior aspect of the pear shaped pad. The central groove line of the mandibular posterior teeth is placed over the crest of the residual ridge The number and size of posterior teeth are in harmony with space available from the distal of canine to the beginning of the ascending ramus The inter-dental wax fills the embrasures up to the contact points Adequate inter-dental wax fills the embrasures to allow for finishing of the acrylic resin A 4mm band of simulated attached gingiva is present, elevated to simulate buccal bone A 1mm band of wax is lingual to the posterior teeth to allow for finishing of the acrylic resin Wax does not overlap onto the beginning/lingual of the ridge-lap of the anterior teeth The buccal shelf area is concave, of adequate thickness Processed and Polished Prosthesis The acrylic resin free of pits, fissures, and porosity The acrylic resin is polished on all non-tissue bearing areas The denture borders are anatomically complete No evidence of flash remains on the denture borders The denture bases remain adequately thick for rigidity Remount Casts (if required) The denture borders are well supported around the buccal periphery Base is 10mm thick at the thinnest portion of the cast 4rnm wide land area throughout the circumference of the cast Removable Partial Dentures Custom Impression Trays Rigid and fabricated from the appropriate material Covers all indicated anatomy Handles do not interfere with border molding movements, formed as prescribed Impression material retentive features included in the tray as prescribed Rests Follow the dimensions and location of the design Fill the prepared rest seats completely Are minimally 1.5mm thick Are no greater in contour than the original marginal ridge/buccal cusp ridge/fossae area Minor Connector Follow the dimensions and location of the design Are broad and fan shaped at the junction with the major connecter Are minimally 1.5mm thick Crosses the gingival margin at 90 degrees Proximal Plates Follow the dimensions and location of the design Are thinned and tapered only at the marginal ridge areas, when no rest is present Major Connectors Follow the dimensions and location of the design Have definitive external finish lines Have definitive internal finish lines Denture Base Retention Follow the dimensions and location of the design Show a broad connection to the major connector Are not extended more than 2mm buccal to the crest of the residual ridge Contains a tissue-stop that contacts the residual ridge of the master cast Retainers, Indirect Follow the dimensions and location of the design Are broad and fan shaped at the junction with the major connector Are minimally 1.5mm thick Crosses the gingival margin at 90 degrees Retainers, Direct Follow the dimensions and location of the design Are uniformly tapered to the retentive tip Are minimally 1.5mm wide Wax Trial Removable Partial Dentures, Maxillary The midline of the arranged teeth matches the marked midline of the occlusion rim The facial surfaces of the anterior teeth are placed in the same plane as the contoured facial surface of the occlusion rims The incisal edges of the anterior teeth are placed in the same plane as the incisal surface of the occlusion rim The inter-dental wax fills the embrasures up to the contact points Adequate inter-dental wax fills the embrasures to allow for finishing of the acrylic A 4mm band of simulated attached gingiva is present to simulate buccal bone A 1mm band of wax is palatal to the posterior teeth to allow for finishing of the acrylic resin Wax does not overlap onto the beginning/palatal of the ridge-lap area of the anterior teeth The opposing occlusion contacts into proper interdigitation at the established vertical dimension of occlusion Wax Trial Removable Partial Dentures, The midline of the a teeth matches the marked midline of the occlusion rims. The facial surfaces of the a teeth are placed in the same plane as the contoured facial surfaces of the occlusion rims. The incisal edges of the anterior teeth are placed in the same plane as the incisal surface of the occlusion rim. The occlusal plane of the mandibular posterior teeth is at the appropriately indicated superior aspect of the pear shaped pad. The central groove line of the mandibular posterior teeth is placed over the crest of the residual ridge The number and size of posterior teeth is in harmony with space available from the distal of the canine to the beginning of the ascending ramus The inter-dental wax fills the embrasures up to the contact points Adequate inter-dental wax fills the embrasures to allow for finishing of the acrylic resin A 4mm band of simulated attached gingiva is present, elevated to simulate buccal bone A 1mm band of wax is lingual to the posterior teeth to allow for finishing of the acrylic resin Wax does not overlap onto the beginning of the ridge-lap area of the anterior teeth The buccal shelf area is concave, of adequate thickness Processed and Polished Prosthesis The acrylic resin is free of pits, fissures, and porosity A smooth junction exists between the acrylic resin and external finish lines The acrylic resin is polished an all non tissue bearing areas The denture borders are anatomically complete No evidence of flash remains on the denture borders The denture bases remain adequately thick for rigidity Fixed Partial Dentures (FPD)/Crown Custom Trays Indicated relief has been well adapted Is well adapted to the teeth and residual ridge Covers all indicated anatomy Completely fills the vestibule Is extended to the beginning of the land area when indicated Is adequate for rigidity Is smooth and free of sharp areas Working Casts/Dies All necessary anatomic landmarks are included Dies are stable, retentive, and do not rotate No bubbles or defects present in the cast Dies are properly trimmed, retaining as much root structure as possible Die spacer is applied to prepared surfaces leaving 1 mm free at margin All dies are numbered. Cut-Back Design for Veneer Application Coping/wax crown cut-back design allows for a uniform 2mm thickness of veneer Proximal cut-back design allows for marginal ridge veneer support Rigid connector size is maximized, within the constraints, for periodontal health and esthetics A uniform transition exists between metal and veneer material Veneer Application Axial contours are within normal limits for the particular tooth and/or arch form Applied veneer shade matches the requested shade per shade guide submitted or universal (Vita, Trubyte, Ivoclar, etc.) system Finish/Polish of FPD/Crown Axial contours are within normal limits for the particular tooth and/or arch form A uniform transition exists between metal and veneer material No unsupported veneer material remains on the allow substructure All margins are closed on the die The established vertical dimension of occlusion is maintained when the FPD/crown is articulated The veneer material is appropriately finished (glazed, polished, etc.) The substructure metal is highly polished Surveyed Crowns for Removable Partial Denture Abutments All aspects of FPD/crown fabrication are employed Posterior occlusal rests: are � the width of the buccal-lingual cusp tip width are spoon-shaped, deepest toward the center of the tooth form an acute angle with the guide at the most axial point re-establish original marginal ridge contours maintain occlusal contours Cingulum rests: are placed in the gingival 1/3 of the crown to avoid occlusal interferences provide a positive stop for the rem...
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/fe9543d808974d1f9b47642eaebc9764/view)
- Place of Performance
- Address: Brockton VA Medical Center;940 Belmont Street, Brockton, MA 02301-5596;and Jamaica Plain VA Medical Center;150 S. Huntington Ave, Jamaica Plain MA 02132-4927, USA
- Country: USA
- Country: USA
- Record
- SN05590679-F 20200318/200316230150 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |