SOLICITATION NOTICE
65 -- NEW - NTX ACU-LOC 2 Hexalobe Instruments
- Notice Date
- 3/16/2020 1:47:36 PM
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- 257-NETWORK CONTRACT OFFICE 17 (36C257) ARLINGTON TX 76006 USA
- ZIP Code
- 76006
- Solicitation Number
- 36C25720Q0385
- Response Due
- 3/20/2020 12:00:00 AM
- Archive Date
- 04/19/2020
- Point of Contact
- Ognian Ivanov ognian.ivanov@va.gov
- E-Mail Address
-
ognian.ivanov@va.gov
(ognian.ivanov@va.gov)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Awardee
- null
- Description
- The Department of Veterans Affairs North Texas Veterans Health Care System in Dallas, TX is posting this combined Synopsis/Solicitation for ACU-LOC 2 Hexalobe Instruments, through the Contracting Officer in San Antonio, Texas. The government intends to make a contract award to the Lowest Price Technically Acceptable vendor that can provide the required items in accordance to the attached documents, as a result of this solicitation for quotes. This action is a total small business set-aside only. The NAICS is 339112. Responses to this notice will be used by the Government to make appropriate evaluations and award decisions. Please submit all required information to Ognian Ivanov via e-mail: ognian.ivanov@va.gov by Friday, March 20, 2020. Place(s) of Performance North Texas VA Health Care System, 4500 S. Lancaster Rd. Dallas, TX 75216-7167 Scope The North Texas VA Health Care System is requesting Unique Instruments: Kickstand Posts (Medical Grade Stainless Steel): Are threaded plate posts designed to assist with distal radius volar tilt correction by lifting the proximal end of the plate away from the radial shaft to form a stable platform with which to achieve distal screw fixation Six different Kickstand posts angles are offered to assist with corrective osteotomies and dorsally displaced fractures (a) Five of the KickStand posts are offered in finite increments of 5DEG, 10DEG, 15DEG, 20DEG and 25DEG osteotomy angles (b) A fully threaded option for fracture allows for volar tilt correction between 5 and 30 degrees Cannulated Locking Bolt (Medical Grade Stainless Steel) and Targeting Guide (PEEK) Accepts the 2.0mm Quick Release Drill Multiple locking bolt positions provide the ability to insert the locking bolt into any of the distal 2.3 m The fracture visualization window is designed to allow access to the fracture through the targeting guide Radiopaque Positioning Posts (Distal Row) are designed to allow visualization of the distal row screws trajectory without K-wire placement Radiopaque Positioning Post (Radial Styloid) is designed to assist with positioning of the plate prior to K-wire and screw fixation. Under fluoroscopy, shows the trajectory of the distal radial styloid screw prior to plate placement without drilling or K-wire placement A styloid K-wire guide allows insertion of a K-wire into the radial styloid to check plate positioning before final radial styloid screw placement The low-profile radiolucent targeting guides allow the surgeon to target and insert all distal screws. Radiopaque positioning posts have been integrated into the targeting guides to assist with plate placement under fluoroscopy Styloid Positioning Post: To verify plate placement, a radiopaque styloid post is utilized in an anteroposterior (A/P) view to project the trajectory of the most distal styloid screw. To align styloid screw placement, position the wrist under fluoroscopy in an A/P view and adjust the plate so that the positioning post targets the styloid tip. This verifies correct trajectory of the styloid screw prior to drilling. Plate Positioning Handle (Medical Stainless Grade Steel): The Plate Positioning Handle assists with precise plate placement while minimizing radiation exposure to the surgeon s hands. Under fluoroscopy, the handle should line up with the center of the plate and radial shaft to show a true A/P view. This is used to accurately place the proximal shaft of the plate in alignment with the center axis of the radial diaphysis. Fragment Reduction Tool (Medical Grade Stainless Steel): Unique instrument designed to fit through the fracture and fracture visualization in order to reduce articular surface.
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/224f3c05704f43c990fccb935ca26a59/view)
- Place of Performance
- Address: Department of Veterans Affairs;Dallas VA Health Care System;4500 S. Lancaster Rd.;Dallas, TX 75216, USA
- Zip Code: 75216
- Country: USA
- Zip Code: 75216
- Record
- SN05590475-F 20200318/200316230148 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |