SOLICITATION NOTICE
Y -- Construction - Install Heated Saftety Edges on Overhead Doors and Interior Remote Control Stations at Conneaut Lake, PA, AMSA, Army
- Notice Date
- 3/10/2020 2:51:36 PM
- Notice Type
- Presolicitation
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- W6QK ACC-PICA PICATINNY ARSENAL NJ 07806-5000 USA
- ZIP Code
- 07806-5000
- Solicitation Number
- W15QKN-20-Q-5065
- Response Due
- 3/16/2020 10:00:00 AM
- Archive Date
- 03/31/2020
- Point of Contact
- Ellen Widelitz, Phone: 6095622384, SHARON WILSON-EMMONS, Phone: 6095626405
- E-Mail Address
-
ellen.h.widelitz.civ@mail.mil, SHARON.WILSON-EMMONS.CIV@MAIL.MIL
(ellen.h.widelitz.civ@mail.mil, SHARON.WILSON-EMMONS.CIV@MAIL.MIL)
- Small Business Set-Aside
- SBA Total Small Business Set-Aside (FAR 19.5)
- Description
- 03-10-20� QUESTIONS AND ANSWERS ARE NOW POSTED, SEE ATTACHMENT Amended Solicitation 0001�is Posted�on 03 March 2020 for additional work as stated in revised Statement of Work. The purpose of this Amendment 0001 is to: 1. Add additional work as reflected in revised SOW. Contractor shall provide and install 2 New Overhead doors to replace these damaged 2 doors that are being removed.� Please see Revised SOW enclosed herein.� Paragraphs 11.3.1.1 and 11.3.2.1 reflect this. �In addition, Paragraph 11.3.2.3 was added to state that Contractor can connect new safety edges with strip heaters to existing local power. NOTE:� THE TOTAL NUMBER OF DOORS THAT REQUIRE SAFETY EDGING REMAINS AT 20, JUST 2 OF THESE 20 DOORS MUST ALSO BE REPLACED. 2. New Worksheet must be completed� to reflect the 2 new Overhead doors as part of your proposal, see Revised Worksheet Attachment 3. A Site Visit is scheduled for these requirements on Monday 09 March 2020 at 10:00AM Eastern Std time..� PLEASE CONTACT ELLEN WIDELITZ AT ellen.h.widelitz.civ@mail.mil� 609-562-2384 and CYNTHIA CROYLE AT cynthia.a.croyle.ctr@mail.mil��� 412-477-7816����� if you are planning on attending. 4. The due date of the proposals will be extended until Monday, 16 March 2020 at 1:00PM, Eastern Std Time. 5. The Magnitude of Work has been changed to (b) Between $25,000 and $100,000. 6. Performance Bond Clauses have been added, See Clauses 52.228.13 and 52.228-14 7.� All other terms and conditions remain the same. The Army Contracting Command, ACC-NJ, has a requirement for heated safety edging and interior Remote Control Stations�on Overhead Doors at Conneaut Lake AMSA 103/ECS, 6467 Mikewood Blvd, Conneaut Lake, PA 16316-6661.� All work shall be performed in accordance with the Statement of Work (SOW). The Period of Performance will be 60 Calendar Days after the award The required response date will be included in the Instructions to Offerors, in the solicitation. BOTH TECHINCAL AND PRICE PROPOSALS MUST BE SUBMITTED ALONG WITH A PRICE BREAKDOWN.when solicitation is posted For this synopsis, documents are not submitted, your proposal will be deemed unacceptable. It is the responsibility of the offeror to review the webpage for notice of amendments, updates, or changes to the solicitation when posted. The POC for this synopsis is Contract Specialist, Ellen H. Wideliltz, ellen.h.widelitz.civ@mail.mil 609-562-2384 and Contracting Officer, Sharon Wilson-Emmons, sharon.wilson-emmons.civ@mail.mil, 609-562-6405
- Web Link
-
SAM.gov Permalink
(https://beta.sam.gov/opp/3c0186bb39554493b9ad0e7bacec2d7c/view)
- Place of Performance
- Address: Conneaut Lake, PA 16316, USA
- Zip Code: 16316
- Country: USA
- Zip Code: 16316
- Record
- SN05584441-F 20200312/200310230155 (samdaily.us)
- Source
-
SAM.gov Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's SAM Daily Index Page |