Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
SAMDAILY.US - ISSUE OF NOVEMBER 15, 2019 SAM #6560
SOURCES SOUGHT

J -- J--SPS Sterilizer Chamber Cleaning at the VA West Haven and Newington Connecticut locations.

Notice Date
11/13/2019 3:08:06 PM
 
Notice Type
Sources Sought
 
NAICS
811219 — Other Electronic and Precision Equipment Repair and Maintenance
 
Contracting Office
241-NETWORK CONTRACT OFFICE 01 (36C241) TOGUS ME 04330 USA
 
ZIP Code
04330
 
Solicitation Number
36C24120Q0063
 
Response Due
11/19/2019 11:59:59 PM
 
Archive Date
02/17/2020
 
Point of Contact
Contract SpecialistJoshua.Gallien@va.gov
 
E-Mail Address
Joshua.Gallien@va.gov
(Joshua.Gallien@va.gov)
 
Awardee
null
 
Description
Performance Work StatementDepartment of Veterans Affairs (VA)Sources Sought Notice Sterilizer Maintenance This is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of your company s offered services and capabilities. The Government will not pay any costs for responses submitted in response to this Source Sought Notice.This Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the service requirement described below. Vendors are being invited to submit information relative to their potential to fulfill this requirement, in the form of acapability response that addresses the specific requirement identified in this Sources Sought.The Veterans Health Administration (VHA) is seeking to obtain Sterilizer Maintenance VA Medical Center West Haven, CT and Newington CT. The standard of services shall be of quality; meeting or exceeding the general requirements as outlined below.Refer to the General Requirements section below for the requested service description. This Sources Sought is to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy.General Requirements The contractor shall provide all labor, specialized services, supervision and travel necessary to maintain the listed equipment in proper working order in accordance with manufactures specification. Sterilizer cleaning/maintenance services shall be provided afterhours or on weekends at no additional charge to the government. Service dates and times shall be coordinated between the VA and the contractor at the convenience of the government. All services shall be conducted by a certified technician to include chamber cleaning, oxidation removal, stickers etc., and restore the chamber to a like new condition. Contractor shall identify possible discrepancies such as: worn gaskets, worn steam line gaskets, or broken drain plugs etc. All present and potential issues shall be noted on Service Reports. All inspections and cleaning shall include the following: 1. Clean items (remove dirt, rust, spilled solutions, lint and other deposits with proper cleaning equipment and supplies).Professional Cleaning (PC) of chambers includes:1. Preparation of work area2. Removal of oxidation from sterilizer chamber using electrical equipment and environmentally safe solutions 3. Clean up all work areas, remove and properly discard debris after completion4. Follow all VA sterile requirements and polices when entering any de-contamination and sterile areas. All PPE requirements will be followed 5. Cleaning materials, fluids etc. shall be environmentally friendly cleansers that do not require neutralization or specialized disposal requirements. 6. The service must fulfill the yearly cleaning recommendations by AAMI (Association Advancement of Medical Instrumentation and AORN Association of Pre-Operative Registered Nurses) guidelines and standards. 7. Cleaning of listed items shall be performed every 6 months at a minimum. Un-scheduled emergency cleaning shall be billed as needed extra services not included in the routine maintenance service. 8. Contractor shall not use chemical solutions/agents or fiber glass sprays to complete cleaning process. Documentation Service records shall be provided to the COR at the conclusion of all services and maintained by the Facilities Management COR.List of EquipmentSteam Sterilizers Newington Campus 555 Willard Ave Newington, CT 06111GETINGE 733HC88657SN#URA013308GETINGE 633HC88526SN#URA050074 West Haven Campus 950 Campbell Ave West Haven, CT 06516GETINGE HC 73366224SN#07J08050GETINGE HC73366225SN#07H07980Steris Autoclaves Operation Rooms 1 & 5STERIS Sterilizer Rm 1- SterisChimeron-1689897032811320STERIS Sterilizer Rm 5 - SterisChimeron-16 89899032871315Loading CartsLoading Carts 1Loading Carts 2
 
Web Link
SAM.gov Permalink
(https://beta.sam.gov/opp/a9369dd9074842d0bab8e49377bb548a/view)
 
Record
SN05493497-F 20191115/191117154918 (samdaily.us)
 
Source
SAM.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's SAM Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.