AWARD
Y -- BUILDING 37100 RESTROOM & SERVER ROOM REPAIR
- Notice Date
- 9/24/2019
- Notice Type
- Award Notice
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of the Army, US Army Corps of Engineers, USACE District, Albuquerque, Attn: CESPA-CT, 4101 Jefferson Plaza NE, Albuquerque, New Mexico, 87109-3435, United States
- ZIP Code
- 87109-3435
- Solicitation Number
- W912PP19Q0073
- Archive Date
- 10/8/2019
- Point of Contact
- Robert J McPherren,
- E-Mail Address
-
Robert.J.McPherren@usace.army.mil
(Robert.J.McPherren@usace.army.mil)
- Small Business Set-Aside
- N/A
- Award Number
- W912PP19P0061
- Award Date
- 9/23/2019
- Awardee
- Unified Contractor Inc
- Award Amount
- 239,109.05
- Description
- This action was awarded as an 8(a) Sole Source Set-Aside under the authority of section 8(a) of the Small Business Act. The contractor shall furnish all parts, material, labor, equipment and supervision necessary to complete the work for Building 37100 at Portal D. The work shall include the following requirements listed in the specific requirements. SPECIFIC REQUIREMENTS: a. Demolition 1. The Contractor shall remove the existing restroom fixtures and equipment from the men's room as shown on the drawings and prep for new work. The fixtures and equipment include but are not limited to: i. Lavatories ii. Toilets iii. Urinals iv. Flush Valves v. Vanity vi. Mirror vii. Partitions viii. Towel, Soap, and Toilet Paper Dispensers ix. Light Fixtures x. Emergency lighting xi. Accessories 2. The Contractor shall remove and dispose of the existing metal panel separation wall and doorframe in its entirety as shown on the drawings and relocate the existing power receptacle to the adjacent wall. 3. The Contractor shall remove all light fixtures as shown on the drawings. 4. Contractor shall abate existing are as shown on the drawings, approximately 800 square feet. b. Construction 1. The Contractor shall install new men's restroom fixtures and equipment as shown on the drawings. The fixtures and equipment include but are not limited to: i. Lavatories ii. Toilets iii. Urinals iv. Flush Valves v. Solid Surface Counter Top vi. Mirrors vii. Partitions viii. Floor Drain Cover ix. Towel, Soap, and Toilet Paper Dispensers (GFE) 2. The Contractor shall paint all existing painted walls, ceilings, and exposed piping in the Men's room as shown on the drawings. 3. The Contractor shall install new switched LED light fixtures in the Men's restroom, hallway, and storage room as shown on the drawings. The light fixtures shall have at battery back-up emergency light for each restroom, storage room, and hallway as shown on the drawings. 4. The Contractor shall repair new HVAC ducting and diffusers as shown on the drawings. Duct shall be sized to provide enough cooling to accommodate the restrooms, storage room, and existing equipment. 5. The Contractor shall provide and install new 2-ton ductless split system to server room as shown on the drawings.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA47/Awards/W912PP19P0061.html)
- Record
- SN05457441-W 20190926/190924231615-151e20b7d653500d5f14d59f8381cd8c (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |