J -- Air Handler Filter Service AMENDMENT No. 01 __ SITE VISIT Q&As

Notice Date
8/20/2019
 
Notice Type
Modification
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of Veterans Affairs;Ralph H. Johnson VA Medical Center;109 Bee Street;Charleston SC 29403-5799
 
ZIP Code
29403-5799
 
Solicitation Number
36C24719Q0846
 
Response Due
8/23/2019
 
Archive Date
8/28/2019
 
Point of Contact
John Norway, john.norway@va.gov
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Solicitation No. 36C247-19-Q-0846 Air Handler Filter Service WJB Dorn VA Medical Center Columbia, SC FBO Amendment No. 01 SITE VISIT Q&A s Note: The Closing Date for this Requirement remains unchanged as COB on Friday, August 23, 2019. QUESTION: Are the Pre-filters MERV 8 pleated? ANSWER: Yes QUESTION: On Bldg. 100 AHU 13 it shows 21 filters, are they bags? If so, efficiency? ANSWER: AHU 13 is being torn out by Government, so don t worry about that one. QUESTION: What does MP, R, and H stand for? Efficiencies? ANSWER: Minni pleat; rigid; HEPA QUESTION: Is the Sterile OR HEPA efficiency different than that of other AHUs? ANWER: No QUESTION: Can you confirm that the pre-filters are standard capacity pleats or are they high capacity pleats? ANSWER: High Capacity QUESTION: Can you confirm that the 12 Final Filters are 95% efficiency? ANSWER: 85% efficiency QUESTION: On Bldg. 100 VAU-29 the Final Filters with the sizes 11.5, are they also HEPAs and the H was left off? ANSWER: It is 11.5 actual size HEPA QUESTION: There are 2 pleated filters listed in the final filter section (i.e.: Bldg. 100, AHU 17) what is the frequency of the changeout? ANSWER: 6 Months QUESTION: HEPA s are specified as being on an annual frequency. What is the requested frequency of the Pocket bags, V-band, and R-Cell filters? ANSWER: One a Year also QUESTION: Do any served areas or AHU require special scheduling, timing, or after-hours work? ANSWER: A/C16 weekends and 17, 24 early in the morning QUESTION: Any special scheduling during cold months to disable smoke detectors on units with humidifiers? Anything else? Who disables the SD? ANSWER: ECC Operators take out the detectors QUESTION: Are the OR air handler / air handlers HEPA filters replaced on an annual basis with a test / certification included? ANSWER: No just A/C16 QUESTION: Any on-site storage available? For how long? ANSWER: None maybe equipment rooms for a day or so but not a long time QUESTION: If materials are stored in front of the filter sections who is responsible to move it for section access? ANSWER: the government staff will clear anything away QUESTION: Can we receive electronic copies of all AHU and EF filter schedules and filter sizes and quantities that are to be included that was handed out at the Site meeting: ANSWER: Yes QUESTION: How many pockets are required for bag filters? ANSWER: Full size and half size. Please price V-Bank filters. QUESTION: What efficiency is required for bag filters? We are assuming MERV 14, is this correct? ANSWER: V Bank QUESTION: Are the V-Cell filters 4 or 8? ANSWER: 8 QUESTION: What efficiency is required for V-Cell Filters? We are assuming MERV 14, is this correct? ANSWER: 85% V Bank QUESTION: What is the minimum pleats per sq./ft required for the pleated filters? ANSWER: Uncertain QUESTION: What efficiency is required for R-Cell filters? We are assuming MERV 13 ANSWER: 85% QUESTION: On the 4 MP Filters are you currently using die cut mini-pleats and do you want to continue? ANSWER: Yes Building 100 Air Handler lJnits Air Handler Number Location of Air Handler Pre-Filter Size Final Filter Size Return Filter Size AHU-1 5 West 2-24x24x4 2-1x24xl2 1-12x24x4 1- x24xl2 AHU-2 4 West 12-24x24x2 2-20x24x2 4-20x24x2 6-24x24x2 2-20x24x12 6-24x24xl2 AHU-3 2 West 16-16x20x4 AHU-4 AHU-5 3 West Basement West 6-24x24x2 6-24x24xl2 4-24x24x2 16-20x24x2 6-24x24x2 6-24x24xl2 8-24x24xl2 H 4-12x24xl2 H 6-24x24x2 6-24x24x12 - AHU-6 5 East l 6- l 6x25x2 8-24x24xl2 AHU-7 4 East 16-20x25x2 8-24x24xl2 4-12x24xl2 AHU-8 2 East 6-16x25x2 2-12x24x2 24-16x20x2 8-24x24x2 2-12x24x12 8-24x24xl2 AHU-9 3 East 6-24x24x2 6-24x24x2 6-24x24x2 6-24x24xl2 6-24x24xl2 6-24x24xl2 AHU-10 Penthouse 4-16x25x2 9-24x24xl2 H 20-20x25x2 3-24x30xl2 H AHU-11 4 South 4-24x24x2 8-24x24x 12 H 8-16x25x2 16-20x24x2 4-12x24xl2 H 4-20x25x2 AHU-12 Penthouse 6-24x24x2 6-24x24x 12 H 6-24x24x2 6-24x24xl2 6-24x24x12 AHU-13 3 South 2-24x24x2 l 2-24x24x21 2-12x24x21 AHU-14 Penthouse 2-20x25x2 l-20x24xl 2 l-24x24xl 2 AHU-15 3 South 4-20x25x2 2-24x24xl2 H l-24x30xl2 H 4-20x25x2 AHU-16 2 South 16-24x24x4 10-24x24xl2 H 36-12x24x4 MP 5-12x24xl2 H 4- l 2x24x4 MP AHU-17 1 South 3--16x25x4 4-16x20x4 16-20x24x2 8-20x20x2 9-20x25x4 16-20x24x 12 12-20x20x4 8-20x20xl2 AHU-18 Basement South 16-20x24x2 12-20x20x12 8-20x20x2 12-20x24xl2 AHU-19 ECC 20-20x25x2 2-20x20x12 4-16x25x2 9-24x24xl2 4-20x24xl2 AHU-20 ECC 6-20x24x2 6-20x24x12 AHU-21 ECC 16-16x25x2 8-20x25x2 AHU-22 3 West 4-20x20x2 2-24x20x2 AHU-23 Penthouse 4-20x25x2 2-16x25x2 AHU-24 1 East 30-24x24x2 12-20x24xl2 6-12x24x2 6-20x20xl2 6-24x24xl2 AHU-26 Penthouse 20-20x25x2 9-24x24xl2 H 4-16x25x2 3-24x30x12 H AHU-27 Roof of ER/Radiology 4-12x24x2 6-24x24x12 2-24x24x2 6-20x24x2 2-20x24xl2 2-12x24x2 2-20x20x2 8-24x24x2 (Snorkel) AHU-28 3 East 6-24x24x4 6-24x24x12 H AHU-29 2 West 16-16x20x4 4-24x24xl 2 H 2-24x30x12 H VAU-29 2 West 2-24x24x2 2-24x24x2 2-24x24x2 2-12x24x2 2-12x24x2 2-12x24x2 2- 23.375x23.375xl 1.5 2- 23.375xl l.375xl 1.5 AHU-30 1 North 3-24x24x2 3-24x24xl2 3-12x24x2 3-12x24x12 AHU-31 Penthouse 4-20x24x2 4-20x24x4 2-20x20x2 2-20x20x4 2-12x24x12 H 2-24x30x12 H Building 100A Air Handler Units AHU-1 Basement 9-24x24x4 6-24x30x12 H AHU-2 Basement 8-24x24x2 2-12x24x2 8-24x24xl2 2-12x24x12 AHU-3 Basement 4-20x24x2 4-20x20x2 Building 103 Air Handler Units A.HU-1 Penthouse 3-24x24x2 3-l 2x24x2 3-24x24xl2 R 3-12x24xl2 R AHU-2 Penthouse 8-24x24x2 8-24x24x 12 R Building 103A Air Handler Units AHU-3 Penthouse 6-24x24x2 2-12x24x2 6-24x24xi2 R 2-12x24xl2 R AHU-4 Penthouse 6-24x24x2 2-12x24x2 6-24x24xl2 R 2-12x24xl2 R Building 106 Air Handler Units AHU-1 Penthouse 4-16x20x2 3-24x24xl2 2-16x25x2 3-12x24xl2 AHU-2 Penthouse 4-16x20x2 3-24x24xl2 2-16x25x2 3-12x24xl2 AHU-3 Penthouse 4-16x20x2 3-24x24xl2 2-16x25x2 3-12x24xl2 AHU-4 Penthouse 4-20x25x2 6-24x24xl2 2-20x20x2 2-12x24xl2 AHU-5 Penthouse 4-20x25x2 3-24x24xl2 2-20x20x2 3-12x24xl 2 AHU-6 Penthouse 4-20x25x2 3-24x24xl2 2-20x20x2 3-12x24xl2 AHU-7 Penthouse 4-20x25x2 3-24x24xl2 2-20x20x2 3-12x24xl2 AHU-8 Penthouse 2-20x25x2 2-24x24xl2 l-12x24xl 2 AHU-9 Penthouse 2-20x20x2 Building 9 Air Handler Units AHU-1 Penthouse 4-16x20x2 2-20x20x2 2-20x20xl2 AHU-2 Penthouse 4-20x20x2 AHU-3 Penthouse 4-24x24x2 6-16x20x2 4-24x24x2 AHU-4 Penthouse 2-16x25x2 l-20x24x2 l-20x24xl2 AHU-5 Penthouse 1-20x24x2.. Building 9A Air Handler Units AHU-1 Basement 4-16x20x2 2-20x25x2 AHU-2 Basement 6-16x20x2 l-20x20x2 Fresh Air Unit Basement 1-20x25x2 3-24x24x29 3-12x24x29 AHU-1 Penthouse AHU-2 Penthouse AHU-3 Penthouse AHU-4 Penthouse Building 5 Air Handler Units RTU-1 Roof Bldg. 120 Building 120 Roof Top Unit Building 21 Roof Top Units RTU-1 Roof Bldg. 21 9-20x24x2 RTU-2 Roof Bldg. 21 3-20x24x2 2-20x30x2 t. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (20-AUG-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/ChaVAMC/VAMCCO80220/36C24719Q0846/listing.html)
 
Record
SN05411965-F 20190822/190820230058 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.