SOLICITATION NOTICE
66 -- Tube Furnace
- Notice Date
- 7/19/2019
- Notice Type
- Combine Synopsis/Solicitation
- Contracting Office
- Bartlett Hall, Bldg 753, West point, NY 10996
- ZIP Code
- 22030
- Solicitation Number
- DRUMUSMACLSTMH0032
- Response Due
- 7/24/2019
- Archive Date
- 1/20/2020
- Point of Contact
- Name: Client Services, Title: Client Services, Phone: 1.877.933.3243, Fax: 703.422.7822
- E-Mail Address
-
Clientservices@fedbid.com;
- Small Business Set-Aside
- Total Small Business
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. The solicitation number is DRUMUSMACLSTMH0032 and is issued as a Request for Quote (RFQ), unless otherwise indicated herein. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2019-03. The associated North American Industrial Classification System (NAICS) code for this procurement is 334516 with a small business size standard of 500.00 employees. This requirement is a [ Small Business ] set-aside and only qualified offerors may submit bids. The solicitation pricing on www.UnisonMarketplace.com will start on the date this solicitation is posted and will end on 2019-07-24 12:00:00.0 Eastern Time or as otherwise displayed at www.UnisonMarketplace.com. FOB Destination shall be West Point, NY 10996 The MICC End User requires the following items, Brand Name or Equal, to the following: LI 001: Ÿ Must be of split-type design, designed for horizontal operation to allow simple insertion of the working tube. Dual shell housing must be constructed of stainless steel. Switchgear and control unit must be integrated into the furnace housing. Ÿ Must accommodate tubes with an OD of 50 mm and length of 850 mm with a heated length of 500 mm. Must include a working tube made of material C 530 including fiber plugs for operation under air in scope of delivery. Must only use fiber materials which are not classified as carcinogenic according to TRGS 905, class 1 or 2. Must also include a Quartz glass working tube and a CrFeAl-Alloy working tube (50 mm OD; 850 mm length). Ÿ Must be capable of heating to ‰¥ 1300 degrees Celsius with a connected load of 3.4 kW using 1 phase/110V power supply. Ÿ Must include charge control with temperature measurement both in the working tube and in the furnace chamber outside the tube, with display of both temperatures with measurement accuracy ± 1 degree Celcius. Must include heating elements on support tubes to provide for free radiation. Ÿ Must utilize three-zone control for optimization of temperature uniformity with Length Constant Temperature +/- 5 K of 250 mm. Ÿ Must include a gas supply system for one non-flammable protective or reaction gas capable of using Air, N2, Ar, 95%/5% N2/H2, 98%/2% Ar/H2, CO2 or He. Must include a gas panel with shut-off valve and flow meter with control valve. Ÿ Controller must be capable of easy programming and storing of at least 50 programs with ‰¥ 40 segments each. Must include a skip function to bypass a segment while the program is running. Must provide for input of ramps by both gradient and temperature (e.g. 100 K/h until 600 °C) and time and temperature (e.g. in 6 hours to 600 °C). Must allow for input of set points in increments of 1 °C resp. 1 min. Must include up to 6 segmental switchable functions (e. g. relays for flaps, gas systems, controlled cooling etc.). Start time must be adjustable via real time clock. Ÿ Must include a bright, high-contrast display with status messages in clear English text. Must include a detailed information menu with: Operating hours counter; kWh counter; Error message history; Output of control values; and Input of control parameters in freely selectable temperature steps. Must be capable of measurement range calibration with up to 10 selectable supporting points. Must include a gradient alarm and temperature alarm functions: min, max, and band alarm Ÿ Must include settable modes in case of power outage: Program continues when power returns, independent from other conditions; Program continues when power returns, if outage time < 2 min. Otherwise, program is aborted; Program continues when power returns, if temperature did not fall more than 50 K. Otherwise, program is aborted; and Program is aborted when power returns, independent from other conditions Ÿ Must include software for preparation of programs on a PC and transfer to controller via USB. Must allow for recording and visualization of process data. Ÿ Bids must include shipping to 10996. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (19-JUL-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/notices/9d56ee8a2b90e9252c299a12c7441ae2)
- Place of Performance
- Address: West Point, NY 10996
- Zip Code: 10996
- Country: US
- Zip Code: 10996
- Record
- SN05375896-F 20190721/190719230029 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |