FBO DAILY - FEDBIZOPPS ISSUE OF JULY 21, 2019 FBO #6449
SOURCES SOUGHT

65 -- WALK-IN COOLER/FREEZER

Notice Date
7/19/2019
 
Notice Type
Synopsis
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 10;8888 Keystone Crossing;Suite 1100;Indianapolis IN 46240
 
ZIP Code
46240
 
Solicitation Number
36C25019Q1175
 
Response Due
7/24/2019
 
Archive Date
7/29/2019
 
Point of Contact
CONTRACT SPECIALIST
 
Small Business Set-Aside
Total Small Business
 
Description
This is a SOURCES SOUGHT request for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine the following: The interest and capability of small business, especially service disabled veteran owned small business and veteran owned small business; Whether the business source is a manufacturer or authorized distributor, verified by an authorization letter from the original equipment manufacturer; Located in the state of Indiana, preferably Northern Indiana, and Size classification relative to the North American Industry Classification System (NAICS) code 333415 for the proposed acquisition. The VA Northern Indiana Healthcare System, Network Contracting Office 10, is seeking potential sources, for a Walk-In Refrigerator and Walk-In Four Compartment Cooler/Freezer at its Fort Wayne Facility with the following specifications: 1. Walk-In Refrigerator Walk-in 1 compartment cooler Approximate size 15 ft 7 in x 11 ft 7 in 1 compartment with floor Ceiling: Single Span Panel Thickness: 4 inch exterior with 4 inch floor with 4 inch ceiling At least 5 year Compressor Warranty At least 5 year System Parts with 1 year Labor Warranty Refrigeration range: -40 to 100 degrees F Finishes: Stainless steel (22 Ga) Structural Components: Structurally reinforced insulated floor with interior ramp Stainless steel (22 Ga) Screws into regular VP base 10/L Stainless Steel (22 Ga) Capping for Ceiling 10/L Stainless Steel (22 Ga) Capping for Floor 2 notch Ceiling Panel Doors/Openings: 1 insulated stainless steel hinged door Interior and exterior kickplate 1 door window 1 stainless steel ramp 1 strip curtain Lighting 4 48 LED lights At least 1 vapor proof LED blub Refrigeration: BLP 214MA-S1B-TSV + 115/1/60 R404A SmartVap + Air Defrost with EEV installed 1 BEZA 010 H8 HT3CB (208 230/3/60) w/ smart speed Scroll Unit 12000 BTU 2. Walk-In Four Compartment Cooler/Freezer Walk-in four compartment Cooler/Freezer with Floor Approximate sizes Walk in Cooler 1 compartment 12 ft 9 in x 17 ft 4 in Walk--in Cooler 2 compartment 13 ft 8 in x 17 ft 4 in Walk-in Freezer 1 compartment 15 ft 8 in x 17 ft 4 in Walk-in Freezer 2 compartment 15 ft 8 in x 17 ft 4 in Ceiling: Multi Span Self Supporting Panel Thickness: 4 Exterior Vertical with 4 Partition, 4 Floor, 4 Ceiling 1260 S/F ½ Plywood Foamed in Panel 16 Notch Floor Panel Pressure Relief Ports (<400 sq/ft) Refrigeration range: -40 to 100 degrees F At least 5 year Compressor Warranty At least 5 year System Parts with 1 year Labor Warranty Finishes: Stainless steel (22-26 Ga) Doors/Openings: 4 Super Doors 1/8 D.T. Kickplate Interior and Exterior 4 Door Windows 4 each 3 Stainless Steel Ramps 4 Strip Curtains Lighting At least (21) 48 LED KEIL 48x754-CL-N Lights Structural Components: Structurally reinforced insulated floor with interior ramps 4 Vapor Proof LED Bulb Screws into regular VP base 100 L/F Self Supporting 6 channel 166 L/F Stainless Steel (22 Ga.) Capping Ceiling 166 L/F Stainless Steel (22 Ga.) Capping Floor 16 Notch Floor Panel 16 Notch Ceiling Panel 20 S/F Stainless Steel (22 Ga)(Closure Metal) 100 S/F Stainless Steel (22 Ga)(Removable Closure) Refrigeration: 2 BEZA 035 L8 HT3CC (208 230/3/60) Must include: Suction Accumulator 1 BEZA 020 H8 HT3CB (208 230/3/60) w/ smart speed Scroll Unit 18200 BTU 1 BEZA 025 H8 HT3CB (208 230/3/60) w/ smart speed Scroll Unit 22700 BTU 1 BLP 320MA S1B TSV+ 115/1/60 R404A SmartVap+ Air Defrost with EEV Installed 1 BLP 314LE S2B TSV+ 208 230/1/60 R404A SmartVap+ Electric Defrost with EEV Installed 1 BLP 317LE S2B TSV+ 208 230/1/60 R404A SmartVap+ Electric Defrost with EEV Installed 1 BLP 423MA S1B TSV+ 115/1/60 R404A SmartVap+ Air Defrost with EEV Installed Installation Requirements: Contractor shall perform all installation services between the hours 5:30 AM and 7:00 PM, 7 Days a week. Contractor shall provide 1 freezer truck and 1 cooler truck for current food on hand during installation. Uncrate, new walk-ins and move into location of installation. Removal and disposal of existing units, including freon from old equipment Contractor shall remove and dispose old outdoor condensing units and install new units in the subbasement with new piping, erect the boxes, and hang coils. Run and insulate refrigeration lines through the ceiling to the subbasement. Contractor shall reinstall suppression sprinkler and sprinkler heads and make all final electrical connections within 5 feet of termination points. Erect the boxes, hang coils and set new condensers in sub-basement. Core drill the floor to sub-basement. Run refrigeration lines Not to Exceed 20 feet each. Insulate refrigeration line. Make final electrical connections to proper sized utilities to within five feet of terminating points. Contractor shall provide and install a temporary plastic wall in front of walk in coolers during demolition and installation to provide a barrier. All contractors that are interested in meeting this requirement are asked to submit the following information: Company Name Company Address DUNS Number Company POC Name Company POC Phone Company POC Email Business Size/Type under NAICS 333415 GSA Contract Number (if applicable) Additional information: All contractors must be registered with the System for Award Management (SAM) at https://www.sam.gov. Any contractor that believes they are capable and desires to claim preference for small business status must be registered with the SBA and meet the requirements of FAR 19.102. Any contractor that believes they are capable and desires to claim preference for veteran owned small business status must be registered with the Vendor Information Pages (VIP) at https://www.vip.vetbiz.gov as an SDVOSB or VOSB. Responses due to Amanda Reid, Contracting Officer, by Wednesday, July 24, 2019, 10:00 a.m. est. time. Please e-mail all responses to Amanda.Reid1@va.gov, NO phone calls are being accepted. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (19-JUL-2019); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link To Document
(https://www.fbo.gov/spg/VA/InVAMC538/InVAMC538/36C25019Q1175/listing.html)
 
Place of Performance
Address: VA NORTHERN INDIANA HEALTHCARE SYSTEM;FT WAYNE VAMC;2121 LAKE AVE;FT WAYNE, IN
Zip Code: 46805
Country: USA
 
Record
SN05375670-F 20190721/190719230019 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.